Chemiluminescence determination of moxifloxacin in pharmaceutical and biological samples based on its enhancing effect of the luminol-ferricyanide system using a microfluidic chip

被引:7
作者
Suh, Yeoun Suk [1 ]
Kamruzzaman, Mohammad [1 ]
Alam, Al-Mahmnur [1 ]
Lee, Sang Hak [1 ]
Kim, Young Ho [2 ]
Kim, Gyu-Man [3 ]
Trung Dung Dang [4 ]
机构
[1] Kyungpook Natl Univ, Dept Chem, Taegu 702701, South Korea
[2] Kyungpook Natl Univ, Res Inst Adv Energy Technol, Taegu 702701, South Korea
[3] Kyungpook Natl Univ, Sch Mech Engn, Taegu 702701, South Korea
[4] Yeungnam Univ, Sch Mech Engn, Gyeongbuk 712749, South Korea
关键词
microfluidic chip; moxifloxacin; chemiluminescence; luminol; ferricyanide; PERFORMANCE LIQUID-CHROMATOGRAPHY; IN-VITRO ACTIVITY; CAPILLARY-ELECTROPHORESIS; HUMAN PLASMA; INJECTION-ANALYSIS; HUMAN URINE; BAY; 12-8039; TABLETS; LEVOFLOXACIN; SERUM;
D O I
10.1002/bio.2536
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive determination of a synthetic fluoroquinolone antibacterial agent, moxifloxacin (MOX), by an enhanced chemiluminescence (CL) method using a microfluidic chip is described. The microfluidic chip was fabricated by a soft-lithographic procedure using polydimethyl siloxane (PDMS). The fabricated PDMS microfluidic chip had three-inlet microchannels for introducing the sample, chemiluminescent reagent and oxidant, and a 500 mu m wide, 250 mu m deep and 82mm long microchannel. An enhanced CL system, luminol-ferricyanide, was adopted to analyze the MOX concentration in a sample solution. CL light was emitted continuously after mixing luminol and ferricyanide in the presence of MOX on the PDMS microfluidic chip. The amount of MOX in the luminol-ferricyanide system influenced the intensity of the CL light. The linear range of MOX concentration was 0.14-55.0ng/mL with a correlation coefficient of 0.9992. The limit of detection (LOD) and limit of quantification (LOQ) were 0.06 and 0.2ng/mL respectively. The presented method afforded good reproducibility, with a relative standard deviation (RSD) of 1.05% for 10ng/mL of MOX, and has been successfully applied for the determination of MOX in pharmaceutical and biological samples. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 43 条
[1]   Atomic absorption spectroscopic, conductometric and colorimetric methods for determination of some fluoroquinolone antibacterials using ammonium reineckate [J].
Al-Ghannam, Sheikha M. .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2008, 69 (04) :1188-1194
[2]   A microfluidic system for evaluation of antioxidant capacity based on a peroxyoxalate chemiluminescence assay [J].
Amatatongchai, Maliwan ;
Hofmann, Oliver ;
Nacapricha, Duangjai ;
Chailapakul, Orawon ;
deMello, Andrew J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (01) :277-285
[3]   Determination of ofloxacin and moxifloxacin and their penetration in human aqueous and vitreous humor by using high-performance liquid chromatography fluorescence detection [J].
Chan, Kwok Ping ;
Chu, Kai On ;
Lai, Wico Wai-Kwan ;
Choy, Kwong Wai ;
Wang, Chi Chiu ;
Lam, Dennis Shun-Chiu ;
Pang, Chi Pui .
ANALYTICAL BIOCHEMISTRY, 2006, 353 (01) :30-36
[4]   Protein chips and nanomaterials for application in tumor marker immunoassays [J].
Chen, Hui ;
Jiang, Chunming ;
Yu, Cheng ;
Zhang, Song ;
Liu, Baohong ;
Kong, Jilie .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) :3399-3411
[5]   Patterning Mammalian Cells for Modeling Three Types of Naturally Occurring Cell-Cell Interactions [J].
Chen, Zhenling ;
Li, Yong ;
Liu, Wenwen ;
Zhang, Dongzhou ;
Zhao, Yuyun ;
Yuan, Bo ;
Jiang, Xingyu .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (44) :8303-8305
[6]   Enantiomeric purity assay of moxifloxacin hydrochloride by capillary electrophoresis [J].
Cruz, LA ;
Hall, R .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (01) :8-13
[7]   Comparative in-vitro activity of moxifloxacin, minocycline and azithromycin against Chlamydia spp. [J].
Donati, M ;
Fermepin, MR ;
Olmo, A ;
D'Apote, L ;
Cevenini, R .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1999, 43 (06) :825-827
[8]   Voltammetric behaviour and determination of moxifloxacin in pharmaceutical products and human plasma [J].
Erk, N .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (05) :1351-1356
[9]   A simple microfluidic chlorine gas sensor based on gas-liquid chemiluminescence of luminol-chlorine system [J].
Gao, Zhao-Xin ;
Li, Hai-Fang ;
Liu, Jiangjiang ;
Lin, Jin-Ming .
ANALYTICA CHIMICA ACTA, 2008, 622 (1-2) :143-149
[10]  
Guerra FLB, 2005, J AOAC INT, V88, P1086