摘要
Continuous flow (CF) hydride generation (HG) using a vapor generation accessory (VGA) coupled to a simultaneous axially viewed inductively coupled plasma optical emission spectrometer (ICP OES) for the ultrasensitive measurement of As, Bi, Sb and Se was investigated. Hydrides were generated in a gas-liquid phase separation system by mixing acidified aqueous sample, additional HCl and reductant (NaBH4) solutions on-line. Instrumental (emission line wavelength, RF power, and flow rates of the sample and waste solutions, along with the sample read delay and wash times) and chemical (concentrations of NaBH4 and HCl in the sample (S) and additional acid (A) solutions) variables affecting the effectiveness of HG were examined to achieve the optimum conditions for single-and multi-element analysis. The limitations of the HG reaction due to potential interference effects between the hydride-forming elements were identified. Satisfactorily, As and Sb hydrides could be generated in a wide range of HCl concentrations either in the S solution or the A solution, i.e. 1-6 (S) or 5-10 (A) mol L-1 HCl. For Bi and Se, HG depended strongly on the acidity and the optimum HCl concentrations for both elements were completely opposite. HG for Bi was the best at the lowest acidity (1 (S) and 5 (A) mol L-1 HCl), whereas the maximum Se responses were acquired using the highest HCl concentrations (6 (S) and 10 (A) mol L-1 HCl). Compromised conditions for the simultaneous measurement of As + Bi + Sb or As + Sb + Se, without any adverse interactions between the elements, were successfully established with an analysis time of similar to 2 min per sample. Under these conditions, the detectability of all the elements was improved greatly (2 orders of magnitude versus ICP OES). Linear concentration ranges (0-20 ng g(-1)), detection limits from 0.027-0.099 ng g(-1) and a precision better than 2% (as RSD) were achieved.
引用
收藏
页码:871 / 880
页数:10
相关论文
共 30 条
[1]  
Agilent Vapor Generation Accessory VGA 77 User's Guide, 2012, AG TECHN INC PUBL
[2]   Optimisation of volatile elements determination by flow injection hydride generation-inductively coupled plasma spectrometry in electrolytic manganese [J].
Antolin, R. ;
Borge, G. ;
Posada, T. ;
Etxebarria, N. ;
Raposo, J. C. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2007, 427 (1-2) :73-77
[3]   Determination of total arsenic content in water by atomic absorption spectroscopy (AAS) using vapour generation assembly (VGA) [J].
Behari, JR ;
Prakash, R .
CHEMOSPHERE, 2006, 63 (01) :17-21
[4]   Comparison of graphite furnace and hydride generation atomic absorption spectrometry for the determination of selenium status in chicken meat [J].
Bohrer, Denise ;
Becker, Emilene ;
do Nascimento, Paulo Cicero ;
Dessuy, Morgana ;
de Carvalho, Leandro Machado .
FOOD CHEMISTRY, 2007, 104 (02) :868-875
[5]  
Dedina J., 1995, HYDRIDE GENERATION A, V1st
[6]   Rapid determination of ultra-trace concentrations of mercury in plants and soils by cold vapour inductively coupled plasma-optical emission spectrometry [J].
Hellings, J. ;
Adeloju, S. B. ;
Verheyen, T. V. .
MICROCHEMICAL JOURNAL, 2013, 111 :62-66
[7]   Determination of selenium by flow injection hydride generation inductively coupled plasma optical emission spectrometry [J].
Hernandez, Princess C. ;
Tyson, Julian F. ;
Uden, Peter C. ;
Yates, Dennis .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (03) :298-304
[8]   The determination of antimony and arsenic concentrations in fly ash by hydride generation inductively coupled plasma optical emission spectrometry [J].
Ilander, Aki ;
Vaisanen, Ari .
ANALYTICA CHIMICA ACTA, 2011, 689 (02) :178-183
[9]   OPTIMIZATION OF CONTINUOUS FLOW HYDRIDE GENERATION INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY FOR SENSITIVITY IMPROVEMENT OF BISMUTH [J].
Kilinc, Ersin ;
Aydin, Firat .
ANALYTICAL LETTERS, 2012, 45 (17) :2623-2636
[10]   Application of multivariate techniques in the optimization of a procedure for the determination of bioavailable concentrations of Se and As in estuarine sediments by ICP OES using a concomitant metals analyzer as a hydride generator [J].
Lopes, Watson da Luz ;
Santelli, Ricardo Erthal ;
Oliveira, Eliane Padua ;
Batista de Carvalho, Maria de Fatima ;
Bezerra, Marcos Almeida .
TALANTA, 2009, 79 (05) :1276-1282