Spectral Imaging of Iodine and Gadolinium Nanoparticles Using Dual-Energy CT

被引:5
|
作者
Badea, C. T. [1 ]
Holbrook, M. [1 ]
Clark, D. P. [1 ]
Ghaghada, K. [2 ]
机构
[1] Duke Univ, Dept Radiol, Ctr Vivo Microscopy, Durham, NC 27710 USA
[2] Texas Childrens Hosp, Singleton Dept Pediat Radiol, Houston, TX 77030 USA
关键词
micro-CT; preclinical; spectral; contrast agents; liposomes; nanoparticles; CONTRAST AGENT;
D O I
10.1117/12.2293625
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Advances in CT hardware have propelled the development of novel CT contrast agents. Combined with the spectral capabilities of X-ray CT, molecular imaging is possible using multiple heavy-metal contrast agents. Nanoparticle platforms make particularly attractive agents because of (1) their ability to carry a large payload of imaging moieties, and (2) their ease of surface modification to facilitate molecular targeting. While several novel imaging moieties based on high atomic number elements are being explored, iodine (I) and gadolinium (Gd) are particularly attractive because they are already in clinical use. In this work, we investigate the feasibility for in vivo discrimination of iodine and gadolinium nanoparticles using dual energy micro-CT. Phantom experiments were performed to measure the CT enhancement for I and Gd over a range of voltages from 40 to 80 kVp using a dual-source micro-CT system with energy integrating detectors having cesium iodide scintillators. The two voltages that provide maximum discrimination between I and Gd were determined to be 50 kVp with Cu filtration and 40 kVp without any filtration. Serial dilutions of I and Gd agents were imaged to determine detection sensitivity using the optimal acquisition parameters. Next, an in vivo longitudinal small animal study was performed using Liposomal I (Lip-I) and Liposomal Gd (Lip-Gd) nanoparticles. The mouse was intravenously administered Lip-Gd and imaged within 1 h post-contrast to visualize Gd in the vascular compartment. The animal was reimaged at 72 h post-contrast with dual-energy micro-CT at 40 kVp and 50 kVp to visualize the accumulation of Lip-Gd in the liver and spleen. Immediately thereafter, the animal was intravenously administered Lip-I and re-imaged. The dual energy sets were used to estimate the concentrations of Gd and I via a two-material decomposition with a non-negativity constraint. The phantom results indicated that the relative contrast enhancement per mg/ml of I to Gd was 0.85 at 40 kVp and 1.79 at 50 kVp. According to the Rose criterion (CNR>5), the detectability limits were 2.67 mg/ml for I and 2.46 mg/ml for Gd. The concentration maps confirmed the expected biodistribution, with Gd concentrated in the spleen and with I in the vasculature of the kidney, liver, and spleen. Iterative reconstruction provided higher sensitivity to detect relatively low concentrations of gadolinium. In conclusion, dual energy micro-CT can be used to discriminate and simultaneously image probes containing I and Gd.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Dual-Energy (Spectral) CT: Applications in Abdominal Imaging
    Blake, Michael A.
    RADIOGRAPHICS, 2011, 31 (04) : 1047 - 1050
  • [2] Pulmonary imaging using dual-energy CT, a role of the assessment of iodine and air distribution
    Ferda, Jiri
    Ferdova, Eva
    Mirka, Hynek
    Baxa, Jan
    Bednarova, Alena
    Flohr, Thomas
    Schmidt, Bernhard
    Matejovic, Martin
    Kreuzberg, Boris
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (02) : 287 - 293
  • [3] Cardiac Dual-Energy CT with Late Iodine Enhancement as an Alternative to Late Gadolinium Enhancement MRI
    Sinitsyn, Valentin
    RADIOLOGY, 2018, 288 (03) : 692 - 693
  • [4] Dual-energy CT imaging of nasopharyngeal cancer cells using multifunctional gold nanoparticles
    Khademi, Sara
    Sarkar, Saeed
    Shakeri-Zadeh, Ali
    Attaran, Neda
    Kharrazi, Sharmin
    Solgi, Razieh
    Ay, Mohammad Reza
    Azimian, Hosein
    Ghadiri, Hossein
    IET NANOBIOTECHNOLOGY, 2019, 13 (09) : 957 - 961
  • [5] Spectral Imaging: Dual-Energy, MultiEnergy and Photon-Counting CT
    Uhlenbrock, Detlev
    RADIOLOGIE, 2023, 63 (01): : 82 - 83
  • [6] Dual-energy CT and coronary imaging
    Kay, Fernando Uliana
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2020, 10 (04) : 1090 - 1107
  • [7] Imaging the Spine with Dual-Energy CT
    Murray N.
    Le M.
    Ebrahimzadeh O.
    Alharthy A.
    Mohammed M.F.
    Ouellette H.A.
    Khosa F.
    Current Radiology Reports, 5 (9)
  • [8] Dual-Energy CT in Oncologic Imaging
    Foti, Giovanni
    Ascenti, Giorgio
    Agostini, Andrea
    Longo, Chiara
    Lombardo, Fabio
    Inno, Alessandro
    Modena, Alessandra
    Gori, Stefania
    TOMOGRAPHY, 2024, 10 (03) : 299 - 319
  • [9] Adrenal Adenomas versus Metastases: Diagnostic Performance of Dual-Energy Spectral CT Virtual Noncontrast Imaging and Iodine Maps
    Nagayama, Yasunori
    Inoue, Taihei
    Oda, Seitaro
    Tanoue, Shota
    Nakaura, Takeshi
    Ikeda, Osamu
    Yamashita, Yasuyuki
    RADIOLOGY, 2020, 296 (02) : 324 - 332
  • [10] Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review
    Xu, Jack Junchi
    Taudorf, Mikkel
    Ulriksen, Peter Sommer
    Achiam, Michael Patrick
    Resch, Timothy Andrew
    Nielsen, Michael Bachmann
    Lonn, Lars Birger
    Hansen, Kristoffer Lindskov
    DIAGNOSTICS, 2020, 10 (10)