Myocardial infarction after left ventricular assist device implantation: Clinical course, role of aortic root thrombus, and outcomes

被引:17
作者
Fried, Justin [1 ]
Han, Jason [1 ]
Naka, Yoshifumi [2 ]
Jorde, Ulrich P. [1 ]
Uriel, Nir [1 ]
机构
[1] Columbia Univ, Dept Med, Med Ctr, Div Cardiol, New York, NY 10027 USA
[2] Columbia Univ, Dept Surg, Med Ctr, New York, NY USA
关键词
D O I
10.1016/j.healun.2013.10.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:112 / 115
页数:4
相关论文
共 7 条
[1]  
Demirozu ZT, 2012, TEX HEART I J, V39, P618
[2]   Readmissions After Implantation of Axial Flow Left Ventricular Assist Device [J].
Hasin, Tal ;
Marmor, Yariv ;
Kremers, Walter ;
Topilsky, Yan ;
Severson, Cathy J. ;
Schirger, John A. ;
Boilson, Barry A. ;
Clavell, Alfredo L. ;
Rodeheffer, Richard J. ;
Frantz, Robert P. ;
Edwards, Brooks S. ;
Pereira, Naveen L. ;
Stulak, John M. ;
Joyce, Lyle ;
Daly, Richard ;
Park, Soon J. ;
Kushwaha, Sudhir S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (02) :153-163
[3]   Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta [J].
May-Newman, K ;
Hillen, B ;
Dembitsky, W .
ASAIO JOURNAL, 2006, 52 (02) :132-139
[4]   Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices [J].
Pak, Sang-Woo ;
Uriel, Nir ;
Takayama, Hiroo ;
Cappleman, Sarah ;
Song, Robert ;
Colombo, Paolo C. ;
Charles, Sandy ;
Mancini, Donna ;
Gillam, Linda ;
Naka, Yoshifumi ;
Jorde, Ulrich P. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (10) :1172-1176
[5]   Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy [J].
Slaughter, Mark S. ;
Naka, Yoshifumi ;
John, Ranjit ;
Boyle, Andrew ;
Conte, John V. ;
Russell, Stuart D. ;
Aaronson, Keith D. ;
Sundareswaran, Kartik S. ;
Farrar, David J. ;
Pagani, Francis D. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (06) :616-624
[6]   Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist Device [J].
Slaughter, Mark S. ;
Rogers, Joseph G. ;
Milano, Carmelo A. ;
Russell, Stuart D. ;
Conte, John V. ;
Feldman, David ;
Sun, Benjamin ;
Tatooles, Antone J. ;
Delgado, Reynolds M., III ;
Long, James W. ;
Wozniak, Thomas C. ;
Ghumman, Waqas ;
Farrar, David J. ;
Frazier, O. Howard .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (23) :2241-2251
[7]   The effect of intermittent low speed mode upon aortic valve opening in calves supported with a jarvik 2000 axial flow device [J].
Tuzun, E ;
Gregoric, ID ;
Conger, JL ;
Golden, K ;
Jarvik, R ;
Frazier, OH ;
Kadipasaoglu, KA .
ASAIO JOURNAL, 2005, 51 (02) :139-143