Analyzing the Influence of a New Dental Implant Design on Primary Stability

被引:30
作者
da Costa Valente, Mariana Lima [1 ]
de Castro, Denise Tornavoi [1 ]
Shimano, Antonio Carlos [2 ]
Lepri, Cesar Penazzo [3 ]
dos Reis, Andrea Candido [1 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthesis, Av Cafe S-N, BR-14040904 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Sch Med Ribeirao Preto, Dept Biomech Med & Rehabil Locomot Apparat, Av Cafe S-N, BR-14040904 Ribeirao Preto, SP, Brazil
[3] Sch Dent Uberaba, Dept Biomat, Uberaba, Brazil
基金
巴西圣保罗研究基金会;
关键词
bone substitutes; implant design; implant stability; osseointegration; FINITE-ELEMENT-ANALYSIS; RESONANCE FREQUENCY-ANALYSIS; SECONDARY STABILITY; PULLOUT STRENGTH; IMMEDIATE; DIAMETER; SCREWS; OSSEOINTEGRATION; INTERFACE; TORQUE;
D O I
10.1111/cid.12324
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe macrogeometry of dental implants strongly influences the primary stability and hence the osseointegration process. PurposeCompare the performance of conventional and modified implant models in terms of primary stability. Materials and MethodsA total of 36 implants (Neodent (R)) with two different formats (n=18): Alvim CM (Conical CM, O 4.3mmx10mm in length) and Titamax Ti (Cylindrical HE, O 4.0mmx11mm in length) were inserted into artificial bone blocks. Nine implants from each set were selected to undergo external geometry changes. The primary stability was quantified by insertion torque and resonance frequency using an Osstell device and the pullout test. One-way analysis of variance and Tukey's test were used for statistical evaluation. ResultsThe comparative analysis of the implants showed a significant increase of the insertion torque for the modified Conical CM implants (p=0.000) and Cylindrical HE (p=0.043); for the resonance frequency the modified Cylindrical HE showed a lower statistical mean (p=0.002) when compared to the conventional model, and in the pullout test both modified implants showed significant reduction (p=0.000). ConclusionsWithin the limitations of this study, the proposed modification showed good stability levels and advantages when compared to the conventional implants.
引用
收藏
页码:168 / 173
页数:6
相关论文
共 26 条
[1]  
Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
[2]   Finite element analysis of the dental implant using a topology optimization method [J].
Chang, Chih-Ling ;
Chen, Chen-Sheng ;
Huang, Chang-Hung ;
Hsu, Ming-Lun .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (07) :999-1008
[3]   EFFECT OF IMPLANT DESIGN ON INITIAL STABILITY OF TAPERED IMPLANTS [J].
Chong, Linus ;
Khocht, Ahmed ;
Suzuki, Jon B. ;
Gaughan, John .
JOURNAL OF ORAL IMPLANTOLOGY, 2009, 35 (03) :130-135
[4]   Evaluation of design parameters of eight dental implant designs: A two-dimensional finite element analysis [J].
Desai, S. R. ;
Desai, M. S. ;
Katti, G. ;
Karthikeyan, I. .
NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2012, 15 (02) :176-181
[5]   The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants [J].
dos Santos, Mychelle Vianna ;
Elias, Carlos Nelson ;
Cavalcanti Lima, Jose Henrique .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (03) :215-223
[6]   The effect of implant design on insertion torque and immediate micromotion [J].
Freitas, Amilcar C., Jr. ;
Bonfante, Estevam A. ;
Giro, Gabriela ;
Janal, Malvin N. ;
Coelho, Paulo G. .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (01) :113-118
[7]   Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading -: Successful vs. failing implants [J].
Glauser, R ;
Sennerby, L ;
Meredith, N ;
Rée, A ;
Lundgren, A ;
Gottlow, J ;
Hämmerle, CHF .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :428-434
[8]   A Comparitive Clinical Study Between Self Tapping and Drill Free Screws as a Source of Rigid Orthodontic Anchorage [J].
Nishant Gupta ;
S. M. Kotrashetti ;
Vijay Naik .
Journal of Maxillofacial and Oral Surgery, 2012, 11 (1) :29-33
[9]   Analysis of the osseous/metal interface of drill free screws and self-tapping screws [J].
Heidemann, W ;
Terheyden, H ;
Gerlach, KL .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2001, 29 (02) :69-74
[10]   Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses [J].
Hsu, CC ;
Chao, CK ;
Wang, JL ;
Hou, SM ;
Tsai, YT ;
Lin, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (04) :788-794