Ruptures of the device landing zone in patients undergoing transcatheter aortic valve implantation: an analysis of TAVI Karlsruhe (TAVIK) patients

被引:30
作者
Schymik, Gerhard [1 ]
Heimeshoff, Martin [2 ]
Bramlage, Peter [3 ]
Wondraschek, Rainer [1 ]
Sueselbeck, Tim [4 ]
Gerhardus, Jan [2 ]
Luik, Armin [1 ]
Posival, Herbert [2 ]
Schmitt, Claus [1 ]
Schroefel, Holger [2 ]
机构
[1] Univ Freiburg, Acad Teaching Hosp, Municipal Hosp Karlsruhe, Med Clin 4,Dept Cardiol, D-76133 Karlsruhe, Germany
[2] Clin Cardiac Surg Karlsruhe, Karlsruhe, Germany
[3] Inst Pharmakol & Pravent Med, Mahlow, Germany
[4] Univ Mannheim, Dept Cardiol, Med Clin 1, D-68131 Mannheim, Germany
关键词
Transcatheter aortic valve replacement; Device landing zone rupture; Dilation; Computed tomography; Annulus rupture; WEIGHTED METAANALYSIS; CONTAINED RUPTURE; ANNULUS RUPTURE; ROOT RUPTURE; REPLACEMENT; OUTCOMES; REGURGITATION; MANAGEMENT; STENOSIS; IMPACT;
D O I
10.1007/s00392-014-0729-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aortic rupture of the device landing zone is a rare complication of transcatheter aortic valve implantation (TAVI) and it is associated with significant mortality. This study reports on the experience of a single-center in a case series of more than 1,000 implants. We explored patient and procedural characteristics aiming at identifying variables that increase the risk for aortic root rupture. Among a total of 1,000 TAVI procedures, six patients (0.6 %) had a rupture of the device landing zone. Five of these patients received the balloon-expandable Edwards SAPIEN valve (5/813; 0.62 %) of which four had a supraannular and one a subannular rupture. One patient received the self-expanding Medtronic CoreValve (1/199; 0.5 %; p = n.s. vs. SAPIEN) and had an annular rupture. Factors that were associated with aortic rupture were: (1) the relative size of the valve compared with the aortic annulus and its geometric form; (2) the need for post-dilation of the new valve because of paravalvular leakage; and (3) the location and severity of calcification. We determined, to avoid aortic rupture, caution may be necessary in the presence of the following conditions: (1) flat sinuses of Valsalva and severe calcifications of either the body or the free edge of the aortic cusps (supraannular rupture); (2) an ellipsoid annulus and bulky calcifications on either the base of the cusps or the rim of the annulus (annular rupture); and (3) a narrow left-ventricular outflow tract (LVOT) and bulky calcification of the LVOT (subannular rupture). After considering these precautions, we observed no case of aortic root rupture in the following 600 cases. The data indicate that to reduce the frequency of aortic rupture, a careful pre-procedural planning appears essential to avoid this serious and potentially deleterious complication.
引用
收藏
页码:912 / 920
页数:9
相关论文
共 21 条
  • [1] Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    Abdel-Wahab, Mohamed
    Zahn, Ralf
    Horack, Martin
    Gerckens, Ulrich
    Schuler, Gerhard
    Sievert, Horst
    Eggebrecht, Holger
    Senges, Jochen
    Richardt, Gert
    [J]. HEART, 2011, 97 (11) : 899 - 906
  • [2] Late contained aortic root rupture and ventricular septal defect after transcatheter aortic valve implantation
    Aminian, Adel
    Lalmand, Jacques
    Dolatabadi, Dariouch
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (01) : E72 - U2175
  • [3] Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement
    Barbanti, Marco
    Yang, Tae-Hyun
    Cabau, Josep Rodes
    Tamburino, Corrado
    Wood, David A.
    Jilaihawi, Hasan
    Blanke, Phillip
    Makkar, Raj R.
    Latib, Azeem
    Colombo, Antonio
    Tarantini, Giuseppe
    Raju, Rekha
    Binder, Ronald K.
    Nguyen, Giang
    Freeman, Melanie
    Ribeiro, Henrique B.
    Kapadia, Samir
    Min, James
    Feuchtner, Gudrun
    Gurtvich, Ronen
    Alqoofi, Faisal
    Pelletier, Marc
    Ussia, Gian Paolo
    Napodano, Massimo
    de Brito, Fabio Sandoli
    Kodali, Susheel
    Norgaard, Bjarne L.
    Hansson, Nicolaj C.
    Pache, Gregor
    Canovas, Sergio J.
    Zhang, Hongbin
    Leon, Martin B.
    Webb, John G.
    Leipsic, Jonathon
    [J]. CIRCULATION, 2013, 128 (03) : 244 - 253
  • [4] The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement A Prospective, Multicenter, Controlled Trial
    Binder, Ronald K.
    Webb, John G.
    Willson, Alexander B.
    Urena, Marina
    Hansson, Nicolaj C.
    Norgaard, Bjarne L.
    Pibarot, Philippe
    Barbanti, Marco
    Larose, Eric
    Freeman, Melanie
    Dumont, Eric
    Thompson, Chris
    Wheeler, Miriam
    Moss, Robert R.
    Yang, Tae-hyun
    Pasian, Sergio
    Hague, Cameron J.
    Giang Nguyen
    Raju, Rekha
    Toggweiler, Stefan
    Min, James K.
    Wood, David A.
    Rodes-Cabau, Josep
    Leipsic, Jonathon
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (05) : 431 - 438
  • [5] Prosthesis Oversizing in Balloon-Expandable Transcatheter Aortic Valve Implantation Is Associated With Contained Rupture of the Aortic Root
    Blanke, Philipp
    Reinoehl, Jochen
    Schlensak, Christian
    Siepe, Matthias
    Pache, Gregor
    Euringer, Wulf
    Geibel-Zehender, Annette
    Bode, Christopher
    Langer, Mathias
    Beyersdorf, Friedhelm
    Zehender, Manfred
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (04) : 540 - 548
  • [6] How should I treat acute aortic annulus rupture during transcatheter aortic valve implantation?
    Debonnaire, Philippe
    Van Herck, Paul L.
    Katsanos, Spyridon
    van der Kley, Frank
    de Weger, Arend
    Palmen, Meindert
    Marsan, Nina Ajmone
    Schalij, Martin J.
    Delgado, Victoria
    [J]. EUROINTERVENTION, 2013, 8 (09) : 1103 - 1104
  • [7] Egenrieder S, 2014, CLIN RES CARDIOL
  • [8] Emergent cardiac surgery during transcatheter aortic valve implantation (TAVI): a weighted meta-analysis of 9,251 patients from 46 studies
    Eggebrecht, Holger
    Schmermund, Axel
    Kahlert, Philipp
    Erbel, Raimund
    Voigtlaender, Thomas
    Mehta, Rajendra H.
    [J]. EUROINTERVENTION, 2013, 8 (09) : 1072 - 1080
  • [9] Clinical Outcomes After Transcatheter Aortic Valve Replacement Using Valve Academic Research Consortium Definitions A Weighted Meta-Analysis of 3,519 Patients From 16 Studies
    Genereux, Philippe
    Head, Stuart J.
    Van Mieghem, Nicolas M.
    Kodali, Susheel
    Kirtane, Ajay J.
    Xu, Ke
    Smith, Craig
    Serruys, Patrick W.
    Kappetein, A. Pieter
    Leon, Martin B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (25) : 2317 - 2326
  • [10] Potential Mechanism of Annulus Rupture During Transcatheter Aortic Valve Implantation
    Hayashida, Kentaro
    Bouvier, Erik
    Lefevre, Thierry
    Hovasse, Thomas
    Morice, Marie-Claude
    Chevalier, Bernard
    Romano, Mauro
    Garot, Philippe
    Farge, Arnaud
    Donzeau-Gouge, Patrick
    Cormier, Bertrand
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (05) : E742 - E746