Integrative Advances for OCT-Guided Ophthalmic Surgery and Intraoperative OCT: Microscope Integration, Surgical Instrumentation, and Heads-Up Display Surgeon Feedback

被引:93
作者
Ehlers, Justis P. [1 ]
Srivastava, Sunil K. [1 ]
Feiler, Daniel [1 ]
Noonan, Amanda I. [2 ]
Rollins, Andrew M. [2 ]
Tao, Yuankai K. [1 ,3 ,4 ]
机构
[1] Cleveland Clin, Cole Eye Inst, Ophthalm Imaging Ctr, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Cleveland Clin, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44106 USA
[4] Cleveland Clin, Cole Eye Inst, Dept Ophthalm Res, Cleveland, OH 44106 USA
来源
PLOS ONE | 2014年 / 9卷 / 08期
基金
美国国家卫生研究院;
关键词
OPTICAL COHERENCE TOMOGRAPHY; ANTERIOR SEGMENT; MEMBRANE; MANEUVERS; SPEED;
D O I
10.1371/journal.pone.0105224
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To demonstrate key integrative advances in microscope-integrated intraoperative optical coherence tomography (iOCT) technology that will facilitate adoption and utilization during ophthalmic surgery. Methods: We developed a second-generation prototype microscope-integrated iOCT system that interfaces directly with a standard ophthalmic surgical microscope. Novel features for improved design and functionality included improved profile and ergonomics, as well as a tunable lens system for optimized image quality and heads-up display (HUD) system for surgeon feedback. Novel material testing was performed for potential suitability for OCT-compatible instrumentation based on light scattering and transmission characteristics. Prototype surgical instruments were developed based on material testing and tested using the microscope-integrated iOCT system. Several surgical maneuvers were performed and imaged, and surgical motion visualization was evaluated with a unique scanning and image processing protocol. Results: High-resolution images were successfully obtained with the microscope-integrated iOCT system with HUD feedback. Six semi-transparent materials were characterized to determine their attenuation coefficients and scatter density with an 830 nm OCT light source. Based on these optical properties, polycarbonate was selected as a material substrate for prototype instrument construction. A surgical pick, retinal forceps, and corneal needle were constructed with semi-transparent materials. Excellent visualization of both the underlying tissues and surgical instrument were achieved on OCT cross-section. Using model eyes, various surgical maneuvers were visualized, including membrane peeling, vessel manipulation, cannulation of the subretinal space, subretinal intraocular foreign body removal, and corneal penetration. Conclusions: Significant iterative improvements in integrative technology related to iOCT and ophthalmic surgery are demonstrated.
引用
收藏
页数:10
相关论文
共 40 条
[1]  
Balicki M, 2009, LECT NOTES COMPUT SC, V5761, P108, DOI 10.1007/978-3-642-04268-3_14
[2]   FEASIBILITY OF INTRASURGICAL SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY [J].
Binder, Susanne ;
Falkner-Radler, Christiane I. ;
Hauger, Christoph ;
Matz, Holger ;
Glittenberg, Carl .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (07) :1332-1336
[3]   Insights into Advanced Retinopathy of Prematurity Using Handheld Spectral Domain Optical Coherence Tomography Imaging [J].
Chavala, Sai H. ;
Farsiu, Sina ;
Maldonado, Ramiro ;
Wallace, David K. ;
Freedman, Sharon F. ;
Toth, Cynthia A. .
OPHTHALMOLOGY, 2009, 116 (12) :2448-2456
[4]   Spectral domain optical coherence tomography - Ultra-high speed, ultra-high resolution ophthalmic imaging [J].
Chen, TC ;
Cense, B ;
Pierce, MC ;
Nassif, N ;
Park, BH ;
Yun, SH ;
White, BR ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (12) :1715-1720
[5]   Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation [J].
Chiu, Stephanie J. ;
Li, Xiao T. ;
Nicholas, Peter ;
Toth, Cynthia A. ;
Izatt, Joseph A. ;
Farsiu, Sina .
OPTICS EXPRESS, 2010, 18 (18) :19413-19428
[6]   INTRAOPERATIVE USE OF HANDHELD SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY IMAGING IN MACULAR SURGERY [J].
Dayani, Pouya N. ;
Maldonado, Ramiro ;
Farsiu, Sina ;
Toth, Cynthia A. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (10) :1457-1468
[7]   Intraoperative Anterior Segment Optical Coherence Tomography: A Novel Assessment Tool during Deep Anterior Lamellar Keratoplasty [J].
De Benito-Llopis, Laura ;
Mehta, Jodhbir S. ;
Angunawela, Romesh I. ;
Ang, Marcus ;
Tan, Donald T. H. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (02) :334-341
[8]  
Ehlers JP, 2014, BR J OPHTHA IN PRESS
[9]  
Ehlers JP, 2014, CURRENT OPI IN PRESS
[10]  
Ehlers JP, 2014, RETINA IN PRESS