In vitro comparison of aortic valve movement after valve-preserving aortic replacement

被引:74
作者
Fries, Roland
Graeter, Thomas
Aicher, Diana
Reul, Helmut
Schmitz, Christoph
Boehm, Michael
Schaefers, Hans-Joachim
机构
[1] Univ Hosp Homburg, Dept Cardiol, Homburg, Germany
[2] Univ Hosp Homburg, Dept Thorac & Cardiovasc Surg, Homburg, Germany
[3] Univ Technol Aachen, Helmholtz Inst Biomed Engn, Aachen, Germany
关键词
D O I
10.1016/j.jtcvs.2006.02.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: In aortic valve regurgitation and aortic dilatation, preservation of the aortic valve is possible by means of root remodeling ( Yacoub procedure) or valve reimplantation ( David procedure). In vivo studies suggest that reimplantation might substantially influence aortic valve-motion characteristics. Evaluation of aortic valve movement in vivo, however, is technically limited and is difficult to standardize. We evaluated the aortic valve-motion pattern echocardiographically in vitro after reimplantation and remodeling. Methods: By using aortic roots of house pigs ( aortoventricular diameter, 22 mm) a Yacoub procedure ( 22-mm graft; Yacoub, n = 5) or a David I procedure ( 24-mm graft; David, n = 5) was performed. Roots after supracommissural replacement ( 22-mm graft; Supra, n = 5) served as control valves. In an electrohydraulic, computer-controlled pulse duplicator the valves were tested at flows of 2, 4, 7, and 9 L/min. Echocardiographically assessed parameters were rapid valve-opening velocity, slow valve-closing velocity, rapid valve-closing velocity, rapid valve-opening time, rapid valve-closing time, ejection time, maximum valve opening, slow valve-closing displacement, and maximum flow velocity. Results: Mean rapid valve-opening velocity and mean rapid valve-closing velocity at a cardiac output of 2 to 9 L/min were fastest in David ( rapid valve-opening velocity: 69 +/- 10 cm/s [ David] vs 39 +/- 4 cm/s [ Yacoub] vs 42 +/- 4 cm/ s [ Supra], P = .0041; rapid valve-closing velocity: 22 +/- 2 cm/s [ David] vs 16 +/- 2 cm/s [ Yacoub] vs 17 +/- 1 cm/s [ Supra], P = .0272), and slow valve-closing velocity was slowest in David ( 0.2 +/- 0.1 cm/s [ David] vs 1.0 +/- 0.3 cm/s [ Yacoub] vs 0.6 +/- 0.1 cm/s [ Supra], P = .0063). With increasing cardiac output, the difference in rapid valve-opening velocity between the groups increased, the difference in slow valve-closing velocity remained unchanged, and the difference in rapid valve-closing velocity decreased. Conclusions: In this standardized experimental setting remodeling of the aortic valve provides significantly smoother valve movements. This might contribute to preservation of a better valve performance during long-term follow-up.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 24 条
[1]  
Aybek T, 2005, J HEART VALVE DIS, V14, P114
[2]   MECHANISM OF CLOSURE OF AORTIC VALVE [J].
BELLHOUSE, BJ ;
BELLHOUSE, FH .
NATURE, 1968, 217 (5123) :86-+
[3]  
BREWER RJ, 1976, J THORAC CARDIOV SUR, V72, P413
[4]   Results of aortic valve-sparing operations [J].
David, TE ;
Armstrong, S ;
Ivanov, J ;
Feindel, CM ;
Omran, A ;
Webb, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (01) :39-46
[5]  
DAVID TE, 1992, J THORAC CARDIOV SUR, V103, P617
[6]  
David TE, 1996, Operative Techniques in Cardiac & Thoracic Surgery-A Comparative Atlas, V1, P44, DOI [10.1016/S1085-5637(07)70080-3, DOI 10.1016/S1085-5637(07)70080-3]
[7]   Analysis of valve motion after the reimplantation type of valve-sparing procedure (David I) with a new aortic root conduit [J].
De Paulis, R ;
De Matteis, GM ;
Nardi, P ;
Scaffa, R ;
Bassano, C ;
Chiariello, L .
ANNALS OF THORACIC SURGERY, 2002, 74 (01) :53-57
[8]   Opening and closing characteristics of the aortic valve after valve-sparing procedures using a new aortic root conduit [J].
De Paulis, R ;
De Matteis, GM ;
Nardi, P ;
Scaffa, R ;
Buratta, MM ;
Chiariello, L .
ANNALS OF THORACIC SURGERY, 2001, 72 (02) :487-494
[9]   Simple modification of "T. David-V" valve-sparing aortic root replacement to create graft pseudosinuses [J].
Demers, P ;
Miller, DC .
ANNALS OF THORACIC SURGERY, 2004, 78 (04) :1479-1481
[10]  