Development of a low-cost copper device for inactivation of microorganism in drinking water for human consumption

被引:6
作者
Arora, Prachi [1 ,2 ,3 ]
Tewary, Suman [3 ,4 ]
Krishnamurthi, Srinivasan [3 ,5 ]
Kumari, Neelam [1 ,2 ,3 ]
机构
[1] CSIR Cent Sci Instruments Org CSIR CSIO, Mat Sci & Sensor Applicat, Sect 30 C, Chandigarh 160030, India
[2] CSIR Cent Sci Instruments Org CSIR CSIO, Thin Film Coating Facil, Sect 30 C, Chandigarh 160030, India
[3] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[4] CSIR Natl Met Lab CSIR NML, Adv Mat & Proc, Jamshedpur 831007, India
[5] CSIR Inst Microbial Technol CSIR IMTECH, Microbial Type Culture & Gene Bank MTCC, Sect 39 A, Chandigarh 160036, India
关键词
Drinking water; Enterobacteriaceae; Metallic copper; Physio-chemical analysis; Storage device; Water purification; DISINFECTION; CORROSION; EXTRACT; AGENT; POINT;
D O I
10.1016/j.jwpe.2022.103302
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Drinking water is a basic necessity for mankind in day-to-day life. Due to several environmental changes in the climate, the problem of water pollution and scarcity increases all over the world, especially in rural and urban areas. To overcome such problems, people are using several alternative techniques for storing drinking water in regular household containers, especially in plastic tubs and plastic buckets, etc. Storing of drinking water in plastic containers increases microbial load with time which leads to various waterborne diseases such as vom-iting, nausea diarrhea, dysentery, etc. To address such problems, the present study develop and design a potable water storage device using copper which will able to reduce water-borne pathogens and can easily fit in any storage container. Experimentation of the developed device was done in both spiked deionized water (DI) (Enterobacteriaceae such as Escherichia coli, Salmonella enterica serovar. typhi, and Pseudomonas aeruginosa) and groundwater samples for analyzing its microbial, and physicochemical (pH, Total Dissolved Solids (TDS), Electrical Conductivity (EC), and copper content) parameters. The results demonstrated that copper devices of 24 and 165 cm2 area can reduce the bacterial population efficiently by 99.99 % in 4 and 8 h in spiked DI and groundwater samples. Copper content was found to be in the range of 0.050-0.095 mg/L (24 cm2) and 0.056-1.75 mg/L (165 cm2) respectively over a period of 0 to 24 h which were characterized using inductively coupled plasma mass spectroscopy. Further, the structural properties of the device were characterized using X-ray Diffraction spectroscopy (XRD). Parameters for the Chick model of inactivation were calculated and eval-uated, all of which show the goodness of fit and predictability at various contact times. The developed device finds applications for travellers, households, school children, office goers, etc.
引用
收藏
页数:14
相关论文
共 75 条
[1]   Nanofiltration systems and applications in wastewater treatment: Review article [J].
Abdel-Fatah, Mona A. .
AIN SHAMS ENGINEERING JOURNAL, 2018, 9 (04) :3077-3092
[2]   Biogenic-Mediated Synthesis of Mesoporous Cu2O/CuO Nano-Architectures of Superior Catalytic Reductive towards Nitroaromatics [J].
Alhumaimess, Mosaed S. ;
Essawy, Amr A. ;
Kamel, Mahmoud M. ;
Alsohaimi, Ibrahim Hotan ;
Hassan, Hassan M. A. .
NANOMATERIALS, 2020, 10 (04)
[3]   The empirical prediction of weight change and corrosion rate of low-carbon steel [J].
Ali, Nurdin ;
Fulazzaky, Mohamad Ali .
HELIYON, 2020, 6 (09)
[4]  
[Anonymous], 2012, 105002012 IS
[5]  
[Anonymous], 2020, 105002012 IS
[6]   Disinfection of bacteriophage MS2 by copper in water [J].
Armstrong, Andrew M. ;
Sobsey, Mark D. ;
Casanova, Lisa M. .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2017, 101 (18) :6891-6897
[7]   Microstructure and crystallographic properties of Cu77Zn21 alloy under the effect of heat treatment [J].
Babouri, Laidi ;
Belmokre, Kamel ;
Kabir, Abdenour ;
Abdelouas, Abdessalem ;
Khettabi, Riad ;
El Mendili, Yassine .
MATERIALS AT HIGH TEMPERATURES, 2019, 36 (02) :165-172
[8]   Use of iodine for water disinfection: Iodine toxicity and maximum recommended dose [J].
Backer, H ;
Hollowell, J .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (08) :679-684
[9]   An optimized staining technique for the detection of Gram positive and Gram negative bacteria within tissue [J].
Becerra S.C. ;
Roy D.C. ;
Sanchez C.J. ;
Christy R.J. ;
Burmeister D.M. .
BMC Research Notes, 9 (1)
[10]  
BIS, 2012, BUR INDIAN STAND IS, V10500, P1