Clinical evaluation of a pressure release valve for paediatric cuffed tracheal tubes

被引:1
作者
Fertl, S. [1 ]
Bernet, V. [2 ]
Schmitz, A. [1 ]
Woitzek, K. [1 ]
Weiss, M. [1 ]
机构
[1] Univ Kinderkliniken Zurich, Anasthesieabt, Zurich, Switzerland
[2] Univ Kinderkliniken Zurich, Abt Intens Med & Neonatol, Zurich, Switzerland
来源
ANAESTHESIST | 2009年 / 58卷 / 01期
关键词
intubation; Trachea; Tube; Cuff pressure; Children; NITROUS-OXIDE DIFFUSION; LARYNGEAL MASK AIRWAYS; ENDOTRACHEAL-TUBES; LARGE-VOLUME; CHILDREN; ANESTHESIA; CONTROLLER; INCREASES; SYSTEM;
D O I
10.1007/s00101-008-1473-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. The safe use of cuffed tracheal tubes for children necessitates a cuff pressure limitation at 20-25 cmH(2)O. The aim of the study was to evaluate the reliability and benefit of a new cuff pressure release valve (opening pressure 20cmH(2)O) for children intubated with a cuffed tracheal tube. Methods. In a prospective, observational trial cuff pressure was recorded in paediatric and adolescent patients intubated with a cuffed tracheal tube during sevoflurane/nitrous oxide anaesthesia. The cuff pressure release valve was interposed between the cuff manometer and the pilot balloon. In 25 patients measurements were started at the initial opening pressure (group A) and in a further 25 patients measurements were started at the minimal sealing cuff pressure (group B). Results. A total of 50 patients, aged from 0.4 to 17.8 years (median 7.4 years) were enrolled in the study. The opening pressure measured (group A) was 19.7 +/- 0.8 cmH(2)O and the cuff sealing pressure (groupB) was 11.7 +/- 2.9 cmH(2)O (range 6-16 cmH(2)O). Mean cuff pressure values in groupA were 20.4 +/- 1.6 cmH(2)O and 16.5 +/- 3.3 cmH(2)O in groupB. In one patient (groupA) the cuff pressure exceeded 25 cmH(2)O and was manually decreased to 20 cmH(2)O. In total, 24 filling procedures (groupA 14; groupB 10) were required during 103.1h of investigation because of cuff pressure drop and audible air leakage, mainly caused by cuff pressure increases and consequent releases during patient positioning. Conclusion. Our data demonstrate that the tested cuff pressure release valve was useful and reliable to limit cuff pressure in tracheal intubated children and adolescents within an acceptable pressure range.
引用
收藏
页码:16 / +
页数:7
相关论文
共 41 条
  • [1] Abud TMV, 2005, CAN J ANAESTH, V52, P878, DOI 10.1007/BF03021785
  • [2] *AHA, 2005, CIRCULATION, V112, P73
  • [3] An in vitro study of the compliance of paediatric tracheal tube cuffs and tracheal wall pressure
    Bernet, V.
    Dullenkopf, A.
    Cannizzaro, V.
    Stutz, K.
    Weiss, M.
    [J]. ANAESTHESIA, 2006, 61 (10) : 978 - 983
  • [4] BRANDT L, 1983, ANAESTHESIST, V32, P459
  • [5] Cuff compliance of pediatric and adult cuffed tracheal tubes:: an experimental study
    Devys, JM
    Schauvliège, F
    Taylor, G
    Plaud, B
    [J]. PEDIATRIC ANESTHESIA, 2004, 14 (08) : 676 - 680
  • [6] Control of tracheal cuff pressure: a pilot study using a pneumatic device
    Duguet, Alexandre
    D'Amico, Leda
    Biondi, Giuseppina
    Prodanovic, Helene
    Gonzalez-Bermejo, Jesus
    Similowski, Thomas
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (01) : 128 - 132
  • [7] Performance of a novel pressure release valve for cuff pressure control in pediatric tracheal tubes
    Dullenkopf, A
    Bernet-Buettiker, V
    Maino, P
    Weiss, M
    [J]. PEDIATRIC ANESTHESIA, 2006, 16 (01) : 19 - 24
  • [8] Nitrous oxide diffusion into tracheal tube cuffs - efficacy of a new prototype cuff pressure release valve
    Dullenkopf, A
    Gerber, AC
    Weiss, M
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (08) : 1072 - 1076
  • [9] Fit and seal characteristics of a new paediatric tracheal tube with high volume-low pressure polyurethane cuff
    Dullenkopf, A
    Gerber, AC
    Weiss, M
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (02) : 232 - 237
  • [10] Dullenkopf A, 2004, CAN J ANAESTH, V51, P997, DOI 10.1007/BF03018487