Postblink changes in total and corneal ocular aberrations

被引:112
作者
Montés-Micó, R
Alió, JL
Muñoz, G
Pérez-Santonja, JJ
Charman, WN
机构
[1] Univ Miguel Hernandez, Inst Oftalmol Alicante, Dept Res Dev & Innovat, Alicante 03015, Spain
[2] Univ Manchester, Dept Opt & Neurosci, Manchester M60 1QD, Lancs, England
关键词
D O I
10.1016/j.ophtha.2003.06.027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: The purpose of this study was to determine objectively the changes in optical aberrations induced by the progressive tear film irregularity after a blink and their effects on retinal image quality. Design: Prospective, consecutive, nonrandomized comparative trial (self-control led). Participants: Twenty healthy subjects. Main Outcome Measures: Corneal and total ocular aberrations were determined in 20 subjects at various time intervals (approximately 0, 10, and 20 seconds) after a blink. Corneal and total aberrations were measured with an Orbscan II topographer (Orbtek Inc, Salt Lake City, UT) and a Zywave aberrometer (Bausch & Lomb, Irvine, CA), respectively. All data were decomposed using Zernike polynomials to yield the root mean square wavefront deviations, in micrometers (Am), for different pupil diameters (3.5, 4.5, 5.5, and 6.5 mm). A merit function (Mf), defined as the volume under the 2-dimensional modulation transfer function as computed from the total wavefront error, was taken as the image quality metric. Results: Both corneal and total aberrations (third order and higher) showed a statistically significant increase with time after the blink for all pupil diameters except 3.5 mm. The magnitude of the increase was greater at larger pupil diameters. For a 6.5-mm pupil, the aberrations increased on average by a factor of 2.5 (total) and 2.5 (corneal). Increases in total aberration were related closely to increases in corneal aberration (P<0.0001). For a 6.5-mm pupil, after 20 seconds, the reduction in optical quality (Mf) among the subjects studied was 21+/-8%. Conclusions: After a blink, the gradual increase in optical aberration associated with the increasingly irregular tear film may cause a progressive reduction in the optical quality of the eye. These changes in aberration with time may partly limit the improvements in visual performance that are achievable by customized corneal ablation. (C) 2004 by the American Academy of Ophthalmology.
引用
收藏
页码:758 / 767
页数:10
相关论文
共 45 条
[1]  
Albarran C, 1997, Cont Lens Anterior Eye, V20, P129, DOI 10.1016/S1367-0484(97)80011-2
[2]  
[Anonymous], 1999, PRINCIPLES OPTICS
[3]   Contributions of the cornea and the lens to the aberrations of the human eye [J].
Artal, P ;
Guirao, A .
OPTICS LETTERS, 1998, 23 (21) :1713-1715
[4]   EFFECTS OF AGING IN RETINAL IMAGE QUALITY [J].
ARTAL, P ;
FERRO, M ;
MIRANDA, I ;
NAVARRO, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (07) :1656-1662
[5]   MEASUREMENT OF MONOCHROMATIC OCULAR ABERRATIONS OF HUMAN EYES AS A FUNCTION OF ACCOMMODATION BY THE HOWLAND ABERROSCOPE TECHNIQUE [J].
ATCHISON, DA ;
COLLINS, MJ ;
WILDSOET, CF ;
CHRISTENSEN, J ;
WATERWORTH, MD .
VISION RESEARCH, 1995, 35 (03) :313-323
[6]   The stability of corneal topography in the post-blink interval [J].
Buehren, T ;
Collins, MJ ;
Iskander, DR ;
Davis, B ;
Lingelbach, B .
CORNEA, 2001, 20 (08) :826-833
[7]  
CronjeDunn S, 1996, OPHTHAL PHYSL OPT, V16, P234, DOI 10.1046/j.1475-1313.1996.95001174.x
[8]  
Daniel M., 2006, Optical Shop Testing
[9]  
GOODMAN JW, 1968, INTRO FOURIER OPTICS, P101
[10]   Measurement of the wave-front aberration of the eye by a fast psychophysical procedure [J].
He, JC ;
Marcos, S ;
Webb, RH ;
Burns, SA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (09) :2449-2456