Implantation of telemetric blood pressure transmitters in Go•ttingen Minipigs: Validation of 24-h systemic blood pressure and heart rate monitoring and influence of anaesthesia

被引:5
|
作者
Carlsen, Michelle Fischer [1 ,2 ]
Christoffersen, Berit Ostergaard [2 ]
Lindgaard, Rikke [1 ,3 ]
Pedersen, Henrik Duelund [2 ,4 ]
Olsen, Lisbeth Hoier [1 ]
机构
[1] Univ Copenhagen, Fac Hlth & Med Sci, Dept Vet & Anim Sci, Ridebanevej 9, DK-1870 Frederiksberg C, Denmark
[2] Novo Nordisk AS, Obes Pharmacol, Global Drug Discovery, Novo Nordisk Pk 1, DK-2760 Malov, Denmark
[3] AniCura ApS, AniCura Online, Herlev, Denmark
[4] Danish Med Agcy, Regulatory & Clin Assessment, Copenhagen, Denmark
关键词
Blood pressure; Heart rate; Hemodynamic; Methods; Minipigs; Telemetry; Anaesthesia; Invasive; Non-invasive; RENIN-ANGIOTENSIN SYSTEM; RATE-VARIABILITY; PROPOFOL; KETAMINE; MIDAZOLAM; XYLAZINE; PIGS; DOGS; IDENTIFICATION; COMBINATION;
D O I
10.1016/j.vascn.2022.107168
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Porcine animal models are used in biomedical research due to anatomical and physiological similarities with human patients. The study aimed to validate telemetric systemic blood pressure (BP) and heart rate (HR) monitoring in Go spacing diaeresis ttingen Minipigs, and in addition to study the effects of three different anaesthesia protocols on telemetric BP and HR measurements.Methods: Eight female Go spacing diaeresis ttingen Minipigs had telemetry transmitters implanted in the right carotid artery. Over ten weeks, systemic 24-h BP and HR monitoring were repeated four times, each ending with an angiotensin II stimulation test. In addition, systemic BP and HR evaluated by telemetry, intra-arterial catheter (IAC) and oscillometric tail-cuff were compared before and after the 10-weeks period. Furthermore, changes in telemetric systemic BP and HR were monitored during anaesthesia in a cross-over design using three different protocols of general anaesthesia: Midazolam/ketamine (MK), propofol, and a combination of tiletamine, zolazepam, xylazine, ketamine and butorphanol (Zoletil-mix).Results: One minipig was excluded and some data were missing due to central-venous catheter issues. The coefficient of variation was below 10% for the 24-h BP and HR measurements, but higher during angiotensin II stimulation. There was a disagreement between the tail-cuff measurement and telemetry/IAC, however the differences were independent of the BP and HR level. All anaesthesia protocols numerically influenced BP and HR, but only propofol statistically significantly decreased the BP.Conclusion: The study showed acceptable reproducibility of telemetric measurement of BP and HR over ten weeks in freely moving Go spacing diaeresis ttingen Minipigs. There was a disagreement between direct and indirect BP measurement, and BP and HR were influenced by all anaesthesia protocols.
引用
收藏
页数:11
相关论文
共 40 条
  • [21] Effect of antihypertensive treatment on 24-h blood pressure variability: pooled individual data analysis of ambulatory blood pressure monitoring studies based on olmesartan mono or combination treatment
    Omboni, Stefano
    Kario, Kazuomi
    Bakris, George
    Parati, Gianfranco
    JOURNAL OF HYPERTENSION, 2018, 36 (04) : 720 - 733
  • [22] Validation of the Oscar 2 oscillometric 24-h ambulatory blood pressure monitor according to the British Hypertension Society protocol
    Goodwin, James
    Bilous, Mary
    Winship, Susan
    Finn, Paul
    Jones, Stephen C.
    BLOOD PRESSURE MONITORING, 2007, 12 (02) : 113 - 117
  • [23] Prospective measurement of blood pressure and heart rate over 24 h in women using combined oral contraceptives with estradiol
    Grandi, Giovanni
    Xholli, Anjeza
    Napolitano, Antonella
    Piacenti, Ilaria
    Bellafronte, Manuela
    Cagnacci, Angelo
    CONTRACEPTION, 2014, 90 (05) : 529 - 534
  • [24] Evaluating 24-h antihypertensive efficacy by the smoothness index: a meta-analysis of an ambulatory blood pressure monitoring database
    Parati, Gianfranco
    Schumacher, Helmut
    Bilo, Grzegorz
    Mancia, Giuseppe
    JOURNAL OF HYPERTENSION, 2010, 28 (11) : 2177 - 2183
  • [25] THE CHANGES IN BLOOD-PRESSURE AFTER ACUTE STROKE - ABOLISHING THE WHITE COAT EFFECT WITH 24-H AMBULATORY MONITORING
    HARPER, G
    FOTHERBY, MD
    PANAYIOTOU, BJ
    CASTLEDEN, CM
    POTTER, JF
    JOURNAL OF INTERNAL MEDICINE, 1994, 235 (04) : 343 - 346
  • [26] Administration of tibolone decreases 24 h heart rate but not blood pressure of post-menopausal women
    Cagnacci, A
    Baldassari, F
    Arangino, S
    Alessandrini, C
    Volpe, A
    MATURITAS, 2004, 48 (02) : 155 - 160
  • [27] Influence of cyclosporine A and FK506 on 24 h blood pressure monitoring in kidney transplant recipients
    Hohage, H
    Bruckner, D
    Arlt, M
    Buchholz, B
    Zidek, W
    Spieker, C
    CLINICAL NEPHROLOGY, 1996, 45 (05) : 342 - 344
  • [28] Feasibility and Reproducibility of Noninvasive 24-h Ambulatory Aortic Blood Pressure Monitoring With a Brachial Cuff-Based Oscillometric Device
    Protogerou, Athanase D.
    Argyris, Antonis
    Nasothimiou, Efthymia
    Vrachatis, Dimitris
    Papaioannou, Theodoros G.
    Tzamouranis, Dimitris
    Blacher, Jacques
    Safar, Michel E.
    Sfikakis, Petros
    Stergiou, George S.
    AMERICAN JOURNAL OF HYPERTENSION, 2012, 25 (08) : 876 - 882
  • [29] Characteristics of 24-h ambulatory blood pressure monitoring in elderly hypertensive males: An observational study of 85 year older patients
    Wang, Junwen
    Xiao, Pijuan
    Ye, Yuyang
    Chen, Xuefeng
    Hu, Xinru
    Yang, Yuanrui
    Peng, Yong
    JOURNAL OF CLINICAL HYPERTENSION, 2024, 26 (11) : 1237 - 1245
  • [30] Pethidine for labor analgesia; monitoring of newborn heart rate, blood pressure and oxygen saturation during the first 24 hours after the delivery
    Konefal, Halina
    Jaskot, Brygida
    Czeszynska, Maria Beata
    GINEKOLOGIA POLSKA, 2012, 83 (05) : 357 - 362