Implantation of telemetric blood pressure transmitters in Go•ttingen Minipigs: Validation of 24-h systemic blood pressure and heart rate monitoring and influence of anaesthesia

被引:5
|
作者
Carlsen, Michelle Fischer [1 ,2 ]
Christoffersen, Berit Ostergaard [2 ]
Lindgaard, Rikke [1 ,3 ]
Pedersen, Henrik Duelund [2 ,4 ]
Olsen, Lisbeth Hoier [1 ]
机构
[1] Univ Copenhagen, Fac Hlth & Med Sci, Dept Vet & Anim Sci, Ridebanevej 9, DK-1870 Frederiksberg C, Denmark
[2] Novo Nordisk AS, Obes Pharmacol, Global Drug Discovery, Novo Nordisk Pk 1, DK-2760 Malov, Denmark
[3] AniCura ApS, AniCura Online, Herlev, Denmark
[4] Danish Med Agcy, Regulatory & Clin Assessment, Copenhagen, Denmark
关键词
Blood pressure; Heart rate; Hemodynamic; Methods; Minipigs; Telemetry; Anaesthesia; Invasive; Non-invasive; RENIN-ANGIOTENSIN SYSTEM; RATE-VARIABILITY; PROPOFOL; KETAMINE; MIDAZOLAM; XYLAZINE; PIGS; DOGS; IDENTIFICATION; COMBINATION;
D O I
10.1016/j.vascn.2022.107168
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Porcine animal models are used in biomedical research due to anatomical and physiological similarities with human patients. The study aimed to validate telemetric systemic blood pressure (BP) and heart rate (HR) monitoring in Go spacing diaeresis ttingen Minipigs, and in addition to study the effects of three different anaesthesia protocols on telemetric BP and HR measurements.Methods: Eight female Go spacing diaeresis ttingen Minipigs had telemetry transmitters implanted in the right carotid artery. Over ten weeks, systemic 24-h BP and HR monitoring were repeated four times, each ending with an angiotensin II stimulation test. In addition, systemic BP and HR evaluated by telemetry, intra-arterial catheter (IAC) and oscillometric tail-cuff were compared before and after the 10-weeks period. Furthermore, changes in telemetric systemic BP and HR were monitored during anaesthesia in a cross-over design using three different protocols of general anaesthesia: Midazolam/ketamine (MK), propofol, and a combination of tiletamine, zolazepam, xylazine, ketamine and butorphanol (Zoletil-mix).Results: One minipig was excluded and some data were missing due to central-venous catheter issues. The coefficient of variation was below 10% for the 24-h BP and HR measurements, but higher during angiotensin II stimulation. There was a disagreement between the tail-cuff measurement and telemetry/IAC, however the differences were independent of the BP and HR level. All anaesthesia protocols numerically influenced BP and HR, but only propofol statistically significantly decreased the BP.Conclusion: The study showed acceptable reproducibility of telemetric measurement of BP and HR over ten weeks in freely moving Go spacing diaeresis ttingen Minipigs. There was a disagreement between direct and indirect BP measurement, and BP and HR were influenced by all anaesthesia protocols.
引用
收藏
页数:11
相关论文
共 40 条
  • [1] Accuracy of pulse rate derived from 24-h ambulatory blood pressure monitoring compared with heart rate from 24-h Holter-ECG
    Lauder, Lucas
    Scholz, Sean S.
    Ewen, Sebastian
    Lettner, Christine
    Ukena, Christian
    Bohm, Michael
    Mahfoud, Felix
    JOURNAL OF HYPERTENSION, 2020, 38 (12) : 2387 - 2392
  • [2] 24-h systolic blood pressure and heart rate recordings in lean and obese adolescents
    Framme, Jenny
    Dangardt, Frida
    Marild, Staffan
    Osika, Walter
    Wahrborg, Peter
    Friberg, Peter
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2006, 26 (04) : 235 - 239
  • [3] Assessment of blood pressure in patients with Type 2 diabetes: comparison between home blood pressure monitoring, clinic blood pressure measurement and 24-h ambulatory blood pressure monitoring
    Masding, MG
    Jones, JR
    Bartley, E
    Sandeman, DD
    DIABETIC MEDICINE, 2001, 18 (06) : 431 - 437
  • [4] 24-h blood pressure monitoring in normal tension glaucoma: night-time blood pressure variability
    N Plange
    M Kaup
    L Daneljan
    H G Predel
    A Remky
    O Arend
    Journal of Human Hypertension, 2006, 20 : 137 - 142
  • [5] 24-h blood pressure monitoring in normal tension glaucoma: night-time blood pressure variability
    Plange, N
    Kaup, M
    Daneljan, L
    Predel, HG
    Remky, A
    Arend, O
    JOURNAL OF HUMAN HYPERTENSION, 2006, 20 (02) : 137 - 142
  • [6] Modification of 24-h ambulatory blood pressure and heart rate during contraception with the vaginal ring: a prospective study
    Cagnacci, Angelo
    Zanin, Renata
    Napolitano, Antonella
    Arangino, Serenella
    Volpe, Annibale
    CONTRACEPTION, 2013, 88 (04) : 539 - 543
  • [7] Influence of Blood Pressure and Heart Rate on PWV Measurement: Assessment Under Real-Time Blood Pressure Monitoring
    Liu, Jinping
    An, Bojing
    Shi, Baixue
    Li, Xuejie
    Qian, Linxue
    PHYSIOLOGICAL RESEARCH, 2024, 73 (06) : 963 - 971
  • [8] Smoking related to 24-h ambulatory blood pressure and heart rate - A study in 352 normotensive Danish subjects
    Mikkelsen, KL
    Wiinberg, N
    Hoegholm, A
    Christensen, HR
    Bang, LE
    Nielsen, PE
    Svendsen, TL
    Kampmann, JP
    Madsen, NH
    Bentzon, MW
    AMERICAN JOURNAL OF HYPERTENSION, 1997, 10 (05) : 483 - 491
  • [9] Telemetric monitoring of fetal blood pressure and heart rate in the freely moving pregnant sheep: a feasibility study
    Abi-Nader, Khalil N.
    Mehta, Vedanta
    Shaw, S. W. Steven
    Bellamy, Tom
    Smith, Neil
    Millross, Laura
    Laverick, Beth
    Filippi, Elisa
    Boyd, Michael
    Peebles, Donald M.
    David, Anna L.
    LABORATORY ANIMALS, 2011, 45 (01) : 50 - 54
  • [10] Blood pressure-lowering effect of simvastatin: a placebo-controlled randomized clinical trial with 24-h ambulatory blood pressure monitoring
    Correa, V., Jr.
    Fuchs, F. D.
    Moreira, L. B.
    Gerhardt, M.
    Fuchs, S. C.
    Sloczinski, C. R.
    Monteggia, R. G.
    Gus, M.
    JOURNAL OF HUMAN HYPERTENSION, 2014, 28 (01) : 62 - 67