Multiplex Real-Time PCR-shortTUB Assay for Detection of the Mycobacterium tuberculosis Complex in Smear-Negative Clinical Samples with Low Mycobacterial Loads

被引:1
作者
Alcaide, Fernando [1 ,2 ,3 ]
Trastoy, Rocio [4 ]
Moure, Raquel [1 ]
Gonzalez-Bardanca, Monica [4 ]
Ambroa, Anton [4 ]
Lopez, Maria [4 ]
Bleriot, Ines [4 ]
Blasco, Lucia [4 ]
Fernandez-Garcia, Laura [4 ]
Tato, Marta [5 ]
Bou, German [4 ]
Tomas, Maria [4 ]
机构
[1] Hosp Univ Bellvitge IDIBELL, Dept Microbiol, Lhospitalet De Llobregat, Spain
[2] Univ Barcelona, Dept Pathol & Expt Therapy, Lhospitalet De Llobregat, Spain
[3] TB Invest Unit Barcelona FUITB, Barcelona, Spain
[4] Univ A Coruna UDC, Hosp A Coruna CHUAC, Microbiol Dept, Biomed Res Inst A Coruna INIBIC, La Coruna, Spain
[5] Hosp Ramon & Cajal, Microbiol Dept, Res Inst Biomed Ramon & Cajal IRYCIS, Madrid, Spain
关键词
LNATm technology; Mycobacterium; real-time PCR; low mycobacterial load; short assay; PCR; DIAGNOSIS; DISEASE; GENES;
D O I
10.1128/JCM.00733-19
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Tuberculosis (TB) remains a major health problem worldwide. Control of TB requires rapid, accurate diagnosis of active disease. However, extrapulmonary TB is very difficult to diagnose because the clinical specimens have very low bacterial loads. Several molecular methods involving direct detection of the Mycobacterium tuberculosis complex (MTBC) have emerged in recent years. Real-time PCR amplification simultaneously combines the amplification and detection of candidate sequences by using fluorescent probes (mainly TaqMan or Molecular Beacons) in automated systems. The multiplex real-time PCR-short assay is performed using locked nucleic acid (LNA) probes (length, 8 to 9 nucleotides) in combination with CodUNG to detect multiple pathogens in clinical samples. In this study, we evaluated the performance of this novel multiplex assay for detecting the MTBC in comparison with that of the conventional culture-based method. The multiplex real-time PCR-short(TUB) assay targets two genes, whiB3 (redox-responsive transcriptional regulator) and pstS1 (phosphate-specific transporter), yielding limits of detection (LOD) of 10 copies and 100 copies, respectively, and amplification efficiencies of 92% and 99.7%, respectively. A total of 94 extrapulmonary samples and pulmonary samples with low mycobacterial loads (all smear negative; 75 MTBC culture positive) were analyzed using the test, yielding an overall sensitivity of 88% and a specificity of 95%. For pleural fluid and tissues/biopsy specimens, the sensitivity was 83% and 85%, respectively. In summary, this technique could be implemented in routine clinical microbiology testing to reduce the overall turnaround time for MTBC detection and may therefore be a useful tool for the diagnosis of extrapulmonary tuberculosis and diagnosis using pulmonary samples with low mycobacterial loads.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Effectiveness of an Integrated Real-Time PCR Method for Detection of the Mycobacterium tuberculosis Complex in Smear-Negative Extrapulmonary Samples in an Area of Low Tuberculosis Prevalence
    Moure, Raquel
    Martin, Rogelio
    Alcaide, Fernando
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (02) : 513 - 515
  • [2] Rapid Detection of Mycobacterium tuberculosis Complex and Rifampin Resistance in Smear-Negative Clinical Samples by Use of an Integrated Real-Time PCR Method
    Moure, Raquel
    Munoz, Laura
    Torres, Miriam
    Santin, Miguel
    Martin, Rogelio
    Alcaide, Fernando
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (03) : 1137 - 1139
  • [3] Evaluation of amplicor PCR assay for direct detection of Mycobacterium tuberculosis in smear-negative specimens.
    Amrane, H
    Guessous, S
    Brugiere, O
    PATHOLOGIE BIOLOGIE, 1997, 45 (06): : 479 - 482
  • [4] Is Real-Time PCR Better than Conventional PCR for Mycobacterium tuberculosis Complex Detection in Clinical Samples?
    Tortoli, Enrico
    Urbano, Pasquale
    Marcelli, Fiorella
    Simonetti, Tullia M.
    Cirillo, Daniela M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (08) : 2810 - 2813
  • [5] Evaluation of the Xpert MTB/RIF Ultra Assay for Direct Detection of Mycobacterium tuberculosis Complex in Smear-Negative Extrapulmonary Samples
    Perez-Risco, Daniel
    Rodriguez-Temporal, David
    Valledor-Sanchez, Ivan
    Alcaide, Fernando
    JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (09)
  • [6] Molecular Detection and Identification of Mycobacterium tuberculosis Complex and Four Clinically Important Nontuberculous Mycobacterial Species in Smear-Negative Clinical Samples by the GenoType Mycobacteria Direct Test
    Bicmen, Can
    Gunduz, Ayriz T.
    Coskun, Meral
    Senol, Gunes
    Cirak, A. Kadri
    Ozsoz, Ayse
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (08) : 2874 - 2878
  • [7] Comparison of smear microscopy, culture, and real-time PCR for quantitative detection of Mycobacterium tuberculosis in clinical respiratory specimens
    Darban-Sarokhalil, Davood
    Fooladi, Abbas Ali Imani
    Maleknejad, Parviz
    Bameri, Zakaria
    Aflaki, Moloud
    Nomanpour, Bizhan
    Yaslianifard, Somayeh
    Modarresi, Mohammad Hossein
    Feizabadi, Mohammad Mehdi
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2013, 45 (04) : 250 - 255
  • [8] Real-time polymerase chain reaction in bronchial aspirate for rapid detection of sputum smear-negative tuberculosis
    Min, J-W.
    Yoon, H. I.
    Park, K. U.
    Song, J-H.
    Lee, C-T.
    Lee, J. H.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2010, 14 (07) : 852 - 858
  • [9] Molecular Detection of Aspergillus: Application of a Real-Time PCR Multiplex Assay in Tissue Samples
    Sabino, Raquel
    Simoes, Helena
    Verissimo, Cristina
    JOURNAL OF FUNGI, 2020, 6 (01)
  • [10] Validation of a Real-Time PCR for the Detection of Mycobacterium tuberculosis Complex Members in Bovine Tissue Samples
    Lorente-Leal, Victor
    Liandris, Emmanouil
    Castellanos, Elena
    Bezos, Javier
    Dominguez, Lucas
    de Juan, Lucia
    Romero, Beatriz
    FRONTIERS IN VETERINARY SCIENCE, 2019, 6