The impact of casing groove location on the flow instability in a counter-rotating axial flow compressor

被引:32
作者
Mao, Xiaochen [1 ]
Liu, Bo [1 ]
Tang, Tianquan [1 ]
Zhao, Hang [1 ]
机构
[1] Northwestern Polytech Univ, Sch Power & Energy, Xian 710072, Shaanxi, Peoples R China
关键词
Counter-rotating; Casing treatment; Tip leakage flow; Stall inception; Double leakage flow; STALL MARGIN IMPROVEMENT; PERFORMANCE; BEHAVIORS; MECHANISM; INCEPTION;
D O I
10.1016/j.ast.2018.01.037
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
To make up the lack of the experimental and numerical investigations about the grooved casing treatment (CT) applied in counter-rotating axial flow compressors (CRAC), the effects of circumferential single grooved CT on the stability enhancement were investigated in the rear rotor of a low-speed CRAC with numerical simulations. The main purpose was to gain a better understanding of the application principle of casing groove and the associated control mechanisms in the CRAC. Parametric studies show that the optimal position of the groove should be located near the blade leading edge in terms of stall margin improvement (SMI) and efficiency enhancement at the near stall condition. Due to the impact of casing groove on tip leakage flow (TLF), the blade tip unloading effect, redirection effect and the compound effect of suction-injection are all beneficial to the SMI. Detailed observation of flow structures illustrates that it is more effective to improve flow stability by controlling the critical TLF released from about mid chord and the stall inception process may be probably changed due to the direct effect of groove on the main TLF released near the blade leading edge. Additionally, the effects that the groove has on rotor outflow blockage, backward axial momentum flux and TLF momentum perpendicular to the blade tip camber inside the tip gap are also studied in the paper. (C) 2018 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:250 / 259
页数:10
相关论文
共 44 条
[1]  
[Anonymous], 1992, 30 AER SCI M EXH
[2]  
[Anonymous], 2012, GT201268801 ASME
[3]  
Bailey E.E., 1972, TM2459 NASA
[4]   The Influence of Tip Clearance Momentum Flux on Stall Inception in a High-Speed Axial Compressor [J].
Cameron, Joshua D. ;
Bennington, Matthew A. ;
Ross, Mark H. ;
Morris, Scott C. ;
Du, Juan ;
Lin, Feng ;
Chen, Jingyi .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2013, 135 (05)
[5]   Casing Treatment for Desensitization of Compressor Performance and Stability to Tip Clearance [J].
Cevik, Mert ;
Huu Duc Vo ;
Yu, Hong .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2016, 138 (12)
[6]   A Computational Fluid Dynamics Study of Circumferential Groove Casing Treatment in a Transonic Axial Compressor [J].
Chen, Haixin ;
Huang, Xudong ;
Shi, Ke ;
Fu, Song ;
Ross, Mark ;
Bennington, Matthew A. ;
Cameron, Joshua D. ;
Morris, Scott C. ;
McNulty, Scott ;
Wadia, Aspi .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2014, 136 (03)
[7]   Stall, Surge, and 75 Years of Research [J].
Day, I. J. .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2016, 138 (01)
[8]   STALL INCEPTION IN AXIAL-FLOW COMPRESSORS [J].
DAY, IJ .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1993, 115 (01) :1-9
[9]   The Impact of Casing Groove Location on Stall Margin and Tip Clearance Flow in a Low-Speed Axial Compressor [J].
Du Juan ;
Li Jichao ;
Gao Lipeng ;
Lin Feng ;
Chen Jingyi .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2016, 138 (12)
[10]   The Self-induced Unsteadiness of Tip Leakage Flow in an Axial Low-Speed Compressor with Single Circumferential Casing Groove [J].
Du Juan ;
Li Jichao ;
Wang Kai ;
Lin Feng ;
Nie Chaoqun .
JOURNAL OF THERMAL SCIENCE, 2013, 22 (06) :565-572