Removal of Ni(II) ions from aqueous solutions using waste of tea factory: Adsorption on a fixed-bed column

被引:244
|
作者
Malkoc, Emine [1 ]
Nuhoglu, Yasar [1 ]
机构
[1] Ataturk Univ, Dept Environm Engn, Fac Engn, TR-25240 Erzurum, Turkey
关键词
fixed-bed adsorption; waste tea; nickel; BDST model; Thomas model;
D O I
10.1016/j.jhazmat.2005.11.070
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The removal efficiency of waste tea from nickel containing aqueous solutions was investigated. All experiments were conducted fixed-bed columns. Experiments were carried out as a function of liquid flow rate (5-20 mL/min), initial Ni(II) concentration (50-200 mg/L), bed height (10-30 cm), pH of feed solution (2.0-5.0) and particle size (0.15-0.25 to 1.0-3.0 mm) of adsorbent. The total adsorbed quantities, equilibrium uptakes and total removal percents of Ni(II) related to the effluent volumes were determined by evaluating the breakthrough curves obtained at different flow rates, different inlet Ni(II) concentrations, different pH value, different bed height and different particle size for waste tea. The longest breakthrough time and maximum of Ni(II) adsorption is obtained at pH 4.0. Decrease in the particle size from 1.0-3.0 to 0.15-0.25 mm resulted in significant increase in the treated volume, breakthrough time and bed capacity. The results show that the column performed well at lowest flow rate. Also, column bed capacity and exhaustion time increased with increasing bed height. When the initial Ni(II) concentration is increased from 50 to 200 mg/L, the corresponding adsorption bed capacity appears to increase from 7.31 to 11.17 mg/g. The bed depth service time (BDST) model and the Thomas model were used to analyze the experimental data and the model parameters were evaluated. Good agreement of the experimental breakthrough curves with the model predictions was observed. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:328 / 336
页数:9
相关论文
共 50 条
  • [21] Fixed - bed Column Adsorption Studies Using Synthetic Hydroxyapatite for Pb(II) Removal from Aqueous Solutions
    Simonescu, Claudia Maria
    Tanase, Iuliana-Raluca
    Purcaru, Irina Nicoleta
    Tardei, Christu
    Marinescu, Virgil
    REVISTA DE CHIMIE, 2019, 70 (05): : 1758 - 1764
  • [22] Oxidized Renewable Materials for the Removal of Cobalt(II) and Copper(II) from Aqueous Solution Using in Batch and Fixed-Bed Column Adsorption
    Vieira Rodrigues, Josilene Aparecida
    Martins, Luide Rodrigo
    Furtado, Lais Milagres
    Pedrosa Xavier, Amalia Luisa
    Rezende de Almeida, Francine Tatiane
    da Silva Lage Moreira, Ana Luisa
    Sacramento Melo, Tania Marcia
    Gil, Laurent Frederic
    Alves Gurgel, Leandro Vinicius
    ADVANCES IN POLYMER TECHNOLOGY, 2020, 2020 : 1 - 17
  • [23] Adsorption of lead (II) from aqueous solution by modified Auricularia matrix waste: A fixed-bed column study
    Qu, Juanjuan
    Song, Tao
    Liang, Jinsong
    Bai, Xin
    Li, Yue
    Wei, Yingnan
    Huang, Siqi
    Dong, Liying
    Jin, Yu
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2019, 169 : 722 - 729
  • [24] Modelling Cd(II) removal from aqueous solutions by adsorption on a highly mineralized peat.: Batch and fixed-bed column experiments
    Gabaldon, Carmen
    Marzal, Paula
    Alvarez-Hornos, F. Javier
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2006, 81 (07) : 1107 - 1112
  • [25] Removal of Pb(II) ions from aqueous solution using water hyacinth root by fixed-bed column and ANN modeling
    Mitra, Tania
    Singha, Biswajit
    Bar, Nirjhar
    Das, Sudip Kumar
    JOURNAL OF HAZARDOUS MATERIALS, 2014, 273 : 94 - 103
  • [26] Removal of Cu(II) from Aqueous Solutions using Dried Activated Sludge and Dried Activated Nano-Sludge: Adsorption on a Fixed-Bed Column
    Ahmari, Zahra
    Khosravi, Morteza
    Niazi, Ali
    ORIENTAL JOURNAL OF CHEMISTRY, 2015, 31 (02) : 933 - 938
  • [27] Removal of Denim Blue from Aqueous Solutions by Inorganic Adsorbents in a Fixed-Bed Column
    Gutierrez-Segura, E.
    Colin-Cruz, A.
    Solache-Rios, M.
    Fall, C.
    WATER AIR AND SOIL POLLUTION, 2012, 223 (08): : 5505 - 5513
  • [28] Removal of Denim Blue from Aqueous Solutions by Inorganic Adsorbents in a Fixed-Bed Column
    E. Gutiérrez-Segura
    A. Colín-Cruz
    M. Solache-Ríos
    C. Fall
    Water, Air, & Soil Pollution, 2012, 223 : 5505 - 5513
  • [29] A fixed-bed column for phosphate removal from aqueous solutions using an andosol-bagasse mixture
    Woumfo, Emmanuel Djoufac
    Siewe, Jean Mermoz
    Njopwouo, Daniel
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2015, 151 : 450 - 460
  • [30] Adsorption of Copper (II) From Aqueous Medium In Fixed-Bed Column By Kenaf Fibres
    Hasfalina, C. M.
    Maryam, R. Z.
    Luqman, C. A.
    Rashid, M.
    2ND INTERNATIONAL CONFERENCE ON CHEMISTRY AND CHEMICAL PROCESS (ICCCP 2012), 2012, 3 : 255 - 263