A MEMS-Based Quad-Wavelength Hybrid Plasmonic-Pyroelectric Infrared Detector

被引:14
作者
Anh Tung Doan [1 ,2 ]
Yokoyama, Takahiro [1 ]
Thang Duy Dao [1 ]
Ishii, Satoshi [1 ]
Ohi, Akihiko [1 ]
Nabatame, Toshihide [1 ]
Wada, Yoshiki [3 ]
Maruyama, Shigenao [4 ]
Nagao, Tadaaki [1 ,2 ]
机构
[1] Natl Inst Mat Sci, Int Ctr Mat Nanoarchitecton, 1-1 Namiki, Tsukuba, Ibaraki 3050044, Japan
[2] Hokkaido Univ, Grad Sch Sci, Dept Condensed Matter Phys, Kita Ku, Kita 10 Nishi 8, Sapporo, Hokkaido 0600810, Japan
[3] Natl Inst Mat Sci, Funct Mat Res Ctr, 1-1 Namiki, Tsukuba, Ibaraki 3050044, Japan
[4] Hachinohe Coll, Natl Inst Technol, 16-1 Uwanotai, Hachinohe, Aomori 0391192, Japan
基金
日本科学技术振兴机构; 日本学术振兴会;
关键词
infrared detector; quad-wavelength; hybrid plasmonic-pyroelectric; MEMS-based; spectral selectivity; PERFECT ABSORBERS; PHOTODETECTORS; SPECTROSCOPY; EMISSION; FILMS; FLAME;
D O I
10.3390/mi10060413
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Spectrally selective detection is of crucial importance for diverse modern spectroscopic applications such as multi-wavelength pyrometry, non-dispersive infrared gas sensing, biomedical analysis, flame detection, and thermal imaging. This paper reports a quad-wavelength hybrid plasmonic-pyroelectric detector that exhibited spectrally selective infrared detection at four wavelengths-3.3, 3.7, 4.1, and 4.5 mu m. The narrowband detection was achieved by coupling the incident infrared light to the resonant modes of the four different plasmonic perfect absorbers based on Al-disk-array placed on a Al2O3-Al bilayer. These absorbers were directly integrated on top of a zinc oxide thin film functioning as a pyroelectric transducer. The device was fabricated using micro-electromechanical system (MEMS) technology to optimize the spectral responsivity. The proposed detector operated at room temperature and exhibited a responsivity of approximately 100-140 mV/W with a full width at half maximum of about 0.9-1.2 mu m. The wavelength tunability, high spectral resolution, compactness and robust MEMS-based platform of the hybrid device demonstrated a great advantage over conventional photodetectors with bandpass filters, and exhibited impressive possibilities for miniature multi-wavelength spectroscopic devices.
引用
收藏
页数:12
相关论文
共 50 条
[21]   INFRARED-EMISSION FROM A FLAME AS THE BASIS FOR CHROMATOGRAPHIC DETECTION OF ORGANIC-COMPOUNDS [J].
HUDSON, MK ;
BUSCH, KW .
ANALYTICAL CHEMISTRY, 1987, 59 (21) :2603-2609
[22]   Polarization-Insensitive Metalenses at Visible Wavelengths [J].
Khorasaninejad, M. ;
Zhuit, A. Y. ;
Roques-Carmes, C. ;
Chen, W. T. ;
Oh, J. ;
Mishra, I. ;
Devlin, R. C. ;
Capasso, F. .
NANO LETTERS, 2016, 16 (11) :7229-7234
[23]   RESONANT CAVITY-ENHANCED (RCE) PHOTODETECTORS [J].
KISHINO, K ;
UNLU, MS ;
CHYI, JI ;
REED, J ;
ARSENAULT, L ;
MORKOC, H .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1991, 27 (08) :2025-2034
[24]  
Korotchenkov G.S., 2013, Integrated Analytical Systems
[25]   Perfect metamaterial absorber [J].
Landy, N. I. ;
Sajuyigbe, S. ;
Mock, J. J. ;
Smith, D. R. ;
Padilla, W. J. .
PHYSICAL REVIEW LETTERS, 2008, 100 (20)
[26]   Taming the Blackbody with Infrared Metamaterials as Selective Thermal Emitters [J].
Liu, Xianliang ;
Tyler, Talmage ;
Starr, Tatiana ;
Starr, Anthony F. ;
Jokerst, Nan Marie ;
Padilla, Willie J. .
PHYSICAL REVIEW LETTERS, 2011, 107 (04)
[27]  
Liu Z., 2003, J FIRE PROT ENG, V13, P129
[28]   Mid-infrared spectroscopy for protein analysis: potential and challenges [J].
Lopez-Lorente, Angela I. ;
Mizaikoff, Boris .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (11) :2875-2889
[29]   A Photonic 1 x 4 Power Splitter Based on Multimode Interference in Silicon-Gallium-Nitride Slot Waveguide Structures [J].
Malka, Dror ;
Danan, Yossef ;
Ramon, Yehonatan ;
Zalevsky, Zeev .
MATERIALS, 2016, 9 (07)
[30]  
Marks R. S., 2015, Nanomaterials for Water Management: Signal Amplification for Biosensing From Nanostructures