Heat production: Longitudinal versus torsional phacoemulsification

被引:47
作者
Han, Young Keun [1 ]
Miller, Kevin M. [1 ]
机构
[1] Univ Calif Los Angeles, Jules Stein Eye Inst, Dept Ophthalmol, David Geffen Sch Med, Los Angeles, CA 90095 USA
关键词
D O I
10.1016/j.jcrs.2009.04.046
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the heat production of longitudinal versus torsional phacoemulsification under strict laboratory test conditions. SETTING: Department of Ophthalmology, David Geffen School of Medicine at UCLA, and Jules Stein Eye Institute, Los Angeles, California, USA. METHODS: Two Infiniti phacoemulsification handpieces were inserted into silicone test chambers filled with a balanced salt solution and imaged serially using a thermal camera. Incision compression was simulated by suspending 25.3 g weights from the silicone chambers. To simulate occlusion of the phacoemulsification tip, the aspiration line was clamped. Peak temperatures were measured 0, 10, 30, 60, and 120 seconds after the commencement of continuous ultrasound power. The 2 handpieces, operating exclusively in longitudinal or torsional modes, were compared 3 ways: (1) using the same power displayed on the instrument console, (2) using identical stroke lengths, and (3) using the same applied energy, a product of stroke length and frequency. RESULTS: For all 3 comparisons, torsional phacoemulsitication resulted in lower temperatures at each time point. At the same displayed power setting, the scenario most familiar to cataract surgeons, longitudinal phacoemulsification elevated temperatures up to 41.5 degrees C more than torsional phacoemulsification. CONCLUSIONS: Torsional phacoemulsification generated less heat than longitudinal phacoemulsification in all 3 comparison tests. Lower operating temperatures indicate lower heat generation within the same volume of fluid, and this may provide additional thermal protection during cataract surgery.
引用
收藏
页码:1799 / 1805
页数:7
相关论文
共 8 条
[1]   Thermal effect on corneal incisions with different phacoemulsification ultrasonic tips [J].
Bissen-Miyajima, H ;
Shimmura, S ;
Tsubota, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (01) :60-64
[2]   Phacoemulsification conditions resulting in thermal wound injury [J].
Ernest, P ;
Rhem, M ;
McDermott, M ;
Lavery, K ;
Sensoli, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (11) :1829-1839
[3]   Torsional mode versus conventional ultrasound mode phacoemulsification - Randomized comparative clinical study [J].
Liu, Yizhi ;
Zeng, Mingbing ;
Liu, Xialin ;
Luo, Lixia ;
Yuan, Zhaohui ;
Xia, Yuanlin ;
Zeng, Yangfa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02) :287-292
[4]   In Water Thermal Imaging Comparison of the Alcon Legacy and AMO Sovereign Phacoemulsification Systems [J].
Miller, Kevin M. ;
Olson, Michael D. .
OPEN OPHTHALMOLOGY JOURNAL, 2008, 2 :20-26
[5]   In-air thermal imaging comparison of Legacy AdvanTec, Millennium, and Sovereign WhiteStar phacoemulsification systems [J].
Olson, MD ;
Miller, KM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (08) :1640-1647
[6]   The physics of phaco: A review [J].
Packer, M ;
Fishkind, WJ ;
Fine, IH ;
Seibel, BS ;
Hoffman, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02) :424-431
[7]   Clinical course of phacoemulsification wound burns [J].
Sugar, A ;
Schertzer, RM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (05) :688-692
[8]   Endothelial cell integrity after phacoemulsification with 2 different handpieces [J].
Vargas, LG ;
Holzer, MP ;
Solomon, KD ;
Sandoval, HP ;
Auffarth, GU ;
Apple, DJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) :478-482