Ultrasound-Guided Vacuum-Assisted Breast Biopsy System for Diagnosis and Minimally Invasive Excision of Intraductal Papilloma Without Nipple Discharge

被引:36
作者
Hu Wei [1 ]
Fan Jiayi [1 ]
Zhang Qinping [1 ]
Shi Junyi [1 ]
Shen Yuan [1 ]
Li Li [1 ]
Su Dongwei [1 ]
Qing Liying [1 ]
机构
[1] Mil Med Coll 2, Changhai Hosp, Dept Gen Surg, Shanghai 200433, Peoples R China
关键词
DUCTOSCOPY; MAMMOTOME; LESIONS;
D O I
10.1007/s00268-009-0171-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background As intraductal papilloma (IP) includes both benign and malignant lesions, it is difficult to decide whether the patient should merely be followed up. The purpose of this study is to validate the ultrasound (US)guided vacuum-assisted breast biopsy system (Mammotome) for diagnosis and minimally invasive excision of IP. Methods Six women with breast cystic-solid lesions without nipple discharge underwent B-US-guided 8-gauge Mammotome biopsy. Interval US surveillance was performed at a median time of 7 months (range 5-12 months). Results All lesions were removed accurately and thoroughly with satisfactory cosmetic outcomes. All of them were histologically diagnosed as IP. No clinically significant hematoma developed. Conclusions The US-guided 8-gauge Mammotome biopsy provides an accurate pathologic diagnosis and successful complete excision of cystic-solid breast lesions. This technique appears to be an alternative to surgical biopsy in IP patients without nipple discharge.
引用
收藏
页码:2579 / 2581
页数:3
相关论文
共 12 条
[1]  
Burbank F, 1996, AM SURGEON, V62, P738
[2]  
[陈为民 CHEN Weimin], 2008, [中国医学计算机成像杂志, Chinese Computed Medical Imaging], V14, P252
[3]   Ultrasound spectrum in intraductal papillary neoplasms of breast [J].
Ganesan, S. ;
Karthik, G. ;
Joshi, M. ;
Damodaran, V. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (946) :843-849
[4]   Diagnostic value of ductoscopy in the diagnosis of nipple discharge and intraductal proliferations in comparison to standard methods [J].
Grunwald, Susanne ;
Heyer, Hans ;
Paepke, Stefan ;
Schwesinger, Guenther ;
Schimming, Anette ;
Hahn, Markus ;
Thomas, Anke ;
Jacobs, Volker R. ;
Ohlinger, Ralf .
ONKOLOGIE, 2007, 30 (05) :243-248
[5]  
HU W, 2008, CHIN J PRACT SURG S, V28, P8
[6]  
Lai JTW, 2000, CAN ASSOC RADIOL J, V51, P232
[7]   Ultrasound-guided mammotome vacuum biopsy for the diagnosis of impalpable breast lesions [J].
Meloni, GB ;
Dessole, S ;
Becchere, MP ;
Soro, D ;
Capobianco, G ;
Ambrosini, G ;
Nardelli, GB ;
Canalis, GC .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (05) :520-524
[8]   A comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome® system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions [J].
Povoski S.P. ;
Jimenez R.E. .
World Journal of Surgical Oncology, 5 (1)
[9]  
Shen KW, 2000, CANCER, V89, P1512, DOI 10.1002/1097-0142(20001001)89:7<1512::AID-CNCR14>3.0.CO
[10]  
2-L