Diffusive sampling and measurement of microbial volatile organic compounds in indoor air

被引:15
作者
Araki, A.
Eitaki, Y. [2 ]
Kawai, T. [2 ]
Kanazawa, A.
Takeda, M.
Kishi, R. [1 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Publ Hlth Sci, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Japan Ind Safety & Hlth Assoc, Osaka Occupat Hlth Serv Ctr, Osaka, Japan
关键词
Microbial volatile organic compounds; Diffusive sampling; Sampling rate; Water-bubbling method; Field study; BUILDING-RELATED SYMPTOMS; FLOOR DUST; PASSIVE SAMPLER; COMPOUNDS MVOCS; EMISSION RATES; MOLDS; GROWTH; METABOLITES; EXPOSURE; DAMPNESS;
D O I
10.1111/j.1600-0668.2009.00606.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Microbial volatile organic compounds (MVOC), chemicals emitted from various microorganisms, in indoor air have been of concern in recent years. For large field studies, diffusive samplers are widely used to measure indoor environments. Since the sampling rate of a sampler is a fundamental parameter to calculate concentration, the sampling rates of eight MVOC with diffusive samplers were determined experimentally using a newly developed water-bubbling method: air was supplied to the MVOC-solutions and the vapor collected in an exposure bag, where diffusive and active samplers were placed in parallel for comparison. Correlations between the diffusive and active samplings gave good linear regressions. The sampling rates were 30-35 ml/min and the detection limits were 0.044-0.178 mu g/m3, as determined by GC/MS analysis. Application of the sampling rates in indoor air was validated by parallel sampling of the diffusive and active sampling method. 5% Propan-2-ol/CS2 was the best solvent to desorb the compounds from absorbents. The procedure was applied to a field study in 41 dwellings. The most frequently detected compounds were hexan-2-one and heptan-2-one, with 97.5% detection rates and geometric mean values of 0.470 and 0.302 mu g/m3, respectively. This study shows that diffusive samplers are applicable to measure indoor MVOC levels.Practical Implications At present, there are still limited reports on indoor Microbial Volatile Organic Compounds (MVOC) levels in general dwellings and occupants' health. Compared with active sampling methods, air sampling using a diffusive sampler is particularly advantageous for use in large field studies due to its smallness, light-size, easy-handling, and cost-effectiveness. In this study, sampling rates of selected MVOC of the diffusive sampler were determined using the water-bubbling method: generating gases by water-bubbling and exposing the diffusive and active samplers at the same time. The obtained sampling rates were validated, and the method was applied to the field study.
引用
收藏
页码:421 / 432
页数:12
相关论文
共 46 条
[1]   Performance of two different types of passive samplers for the GC/ECD-FID determination of environmental VOC levels in air [J].
Begerow, J ;
Jermann, E ;
Keles, T ;
Dunemann, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (04) :399-403
[2]   PASSIVE SAMPLING FOR VOLATILE ORGANIC-COMPOUNDS (VOCS) IN AIR AT ENVIRONMENTALLY RELEVANT CONCENTRATION LEVELS [J].
BEGEROW, J ;
JERMANN, E ;
KELES, T ;
RANFT, U ;
DUNEMANN, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (06) :549-554
[3]   Partitioning behavior of alkan-1-ols between milkfat and aqueous phases as influenced by temperature [J].
Berg, DP ;
Rankin, SA .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (07) :2646-2651
[4]  
DEWEY S, 1995, ZBL HYG UMWELTMED, V197, P504
[5]   Molds in floor dust, building-related symptoms, and lung function among male and female schoolteachers [J].
Ebbehoj, NE ;
Meyer, HW ;
Würtz, H ;
Suadicani, P ;
Valbjorn, O ;
Sigsgaard, T ;
Gyntelberg, F .
INDOOR AIR, 2005, 15 :7-16
[6]   Determination of selected microbial volatile organic compounds by diffusive sampling and dual-column capillary GC-FID -: a new feasible approach for the detection of an exposure to indoor mould fungi? [J].
Elke, K ;
Begerow, J ;
Oppermann, H ;
Krämer, U ;
Jermann, E ;
Dunemann, L .
JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (05) :445-452
[7]   Ocular, airway, and dermal symptoms related to building dampness and odors in dwellings [J].
Engvall, K ;
Norbäck, D .
ARCHIVES OF ENVIRONMENTAL HEALTH, 2002, 57 (04) :304-310
[8]   Sick building syndrome in relation to building dampness in multi-family residential buildings in Stockholm [J].
Engvall, K ;
Norrby, C ;
Norbäck, D .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2001, 74 (04) :270-278
[9]   Detection of microbial volatile organic compounds (MVOCs) produced by moulds on various materials [J].
Fiedler, K ;
Schütz, E ;
Geh, S .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2001, 204 (2-3) :111-121
[10]   PERSONAL DIFFUSIVE SAMPLER FOR METHANOL, A HYDROPHILIC SOLVENT [J].
KAWAI, T ;
YASUGI, T ;
UCHIDA, Y ;
IKEDA, M .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1990, 44 (04) :514-520