Non-constant biaxial bending capacity assessment of CFST columns through interaction diagrams

被引:6
作者
Espinos, Ana [1 ]
Albero, Vicente [2 ]
Romero, Manuel L. [1 ]
Mund, Maximilian [3 ]
Meyer, Patrick [3 ]
Schaumann, Peter [3 ]
机构
[1] Univ Politecn Valencia, Inst Ciencia & Tecnol Hormigon ICITECH, Valencia, Spain
[2] Univ Jaume 1, Dept Mech Engn & Construct, Castellon de La Plana, Spain
[3] Leibniz Univ Hannover, Inst Steel Construct, Hannover, Germany
关键词
biaxial bending; non-constant bending moment; concrete-filled steel tubular columns; finite element analysis; parametric studies; Eurocode; 4; SLENDER BEAM-COLUMNS; STRENGTH REINFORCED-CONCRETE; NONLINEAR-ANALYSIS; STEEL; BEHAVIOR; TESTS; DESIGN; LOADS;
D O I
10.12989/scs.2019.32.4.521
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The mechanical response of concrete-filled steel tubular (CFST) columns subjected to pure compression or uniaxial bending was studied in depth over the last decades. However, the available research results on CFST columns under biaxial bending are still scarce and the lack of experimental tests for this loading situation is evident. At the same time, the design provisions in Eurocode 4 Part 1.1 for verifying the stability of CFST columns under biaxial bending make use of a simplistic interaction curve, which needs to be revised. This paper presents the outcome of a numerical investigation on slender CFST columns subjected to biaxial bending. Eccentricities differing in minor and major axis, as well as varying end moment ratios are considered in the numerical model. A parametric study is conducted for assessing the current design guidelines of EN1994-1-1. Different aspect ratios, member slenderness, reinforcement ratios and load eccentricities are studied, covering both constant and variable bending moment distribution. The numerical results are subsequently compared to the design provisions of EN1994-1-1, showing that the current interaction equation results overly conservative. An alternative interaction equation is developed by the authors, leading to a more accurate yet conservative proposal.
引用
收藏
页码:521 / 536
页数:16
相关论文
共 39 条
[1]  
ABAQUS, 2014, AB STAND VERS 6 14 U, VI
[2]   Proposal of a new method in EN1994-1-2 for the fire design of concrete-filled steel tubular columns [J].
Albero, V. ;
Espinos, A. ;
Romero, M. L. ;
Hospitaler, A. ;
Bihina, G. ;
Renaud, C. .
ENGINEERING STRUCTURES, 2016, 128 :237-255
[3]  
Anderson D., 1992, CALIBRATION COMPOSIT
[4]  
[Anonymous], 2005, Design of Steel Structures
[5]  
[Anonymous], 2004, Eurocode 4
[6]   Analytical approach to failure surfaces in reinforced concrete sections subjected to axial loads and biaxial bending [J].
Bonet, JL ;
Miguel, PF ;
Fernandez, MA ;
Romero, ML .
JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (12) :2006-2015
[7]  
Bresler B., 1960, J AM CONCR I, V57, P481
[8]  
CEN (European Committee for Standardization), 2004, 199211 CEN
[9]   Behaviour of reinforced and concrete-encased composite columns subjected to biaxial bending and axial load [J].
Dundar, Cengiz ;
Tokgoz, Serkan ;
Tanrikulu, A. Kamil ;
Baran, Tarik .
BUILDING AND ENVIRONMENT, 2008, 43 (06) :1109-1120
[10]   Strength of biaxially loaded high strength reinforced concrete columns [J].
Dundar, Cengiz ;
Tokgoz, Serkan .
STRUCTURAL ENGINEERING AND MECHANICS, 2012, 44 (05) :649-661