Contrast-Enhanced Time-Resolved MRA for Follow-Up of Intracranial Aneurysms Treated with the Pipeline Embolization Device

被引:38
作者
Boddu, S. R. [1 ]
Tong, F. C. [1 ,2 ]
Dehkharghani, S. [1 ]
Dion, J. E. [1 ,2 ]
Saindane, A. M. [1 ]
机构
[1] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA USA
[2] Emory Univ, Sch Med, Dept Neurol Surg, Atlanta, GA USA
关键词
DIAGNOSTIC CEREBRAL-ANGIOGRAPHY; ASSISTED COIL EMBOLIZATION; STENT; COMPLICATIONS;
D O I
10.3174/ajnr.A4008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Endovascular reconstruction and flow diversion by using the Pipeline Embolization Device is an effective treatment for complex cerebral aneurysms. Accurate noninvasive alternatives to DSA for follow-up after Pipeline Embolization Device treatment are desirable. This study evaluated the accuracy of contrast-enhanced time-resolved MRA for this purpose, hypothesizing that contrast-enhanced time-resolved MRA will be comparable with DSA and superior to 3D-TOF MRA. MATERIALS AND METHODS: During a 24-month period, 37 Pipeline Embolization Device treated intracranial aneurysms in 26 patients underwent initial follow-up by using 3D-TOF MRA, contrast-enhanced time-resolved MRA, and DSA. MRA was performed on a 1.5T unit by using 3D-TOF and time-resolved imaging of contrast kinetics. All patients underwent DSA a median of 0 days (range, 0-68) after MRA. Studies were evaluated for aneurysm occlusion, quality of visualization of the reconstructed artery, and measurable luminal diameter of the Pipeline Embolization Device, with DSA used as the reference standard. RESULTS: The sensitivity, specificity, and positive and negative predictive values of contrast-enhanced time-resolved MRA relative to DSA for posttreatment aneurysm occlusion were 96%, 85%, 92%, and 92%. Contrast-enhanced time-resolved MRA demonstrated superior quality of visualization (P = .0001) and a higher measurable luminal diameter (P =.0001) of the reconstructed artery compared with 3D-TOF MRA but no significant difference compared with DSA. Contrast-enhanced time-resolved MRA underestimated the luminal diameter of the reconstructed artery by 0.965 +/- 0.497 mm (27% +/- 13%) relative to DSA. CONCLUSIONS: Contrast-enhanced time-resolved MRA is a reliable noninvasive method for monitoring intracranial aneurysms following flow diversion and vessel reconstruction by using the Pipeline Embolization Device.
引用
收藏
页码:2112 / 2118
页数:7
相关论文
共 24 条
[1]   Successful endovascular treatment of three fusiform cerebral aneurysms with the Pipeline Embolization Device in a patient with dilating HIV vasculopathy [J].
Almandoz, Josser E. Delgado ;
Crandall, Benjamin M. ;
Fease, Jennifer L. ;
Scholz, Jill M. ;
Anderson, Ruth E. ;
Kadkhodayan, Yasha ;
Tubman, David E. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (02) :E12
[2]   Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial [J].
Becske, Tibor ;
Kallmes, David F. ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvn ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
RADIOLOGY, 2013, 267 (03) :858-868
[3]   Applications of Time-Resolved MR Angiography [J].
Blackham, Kristine A. ;
Passalacqua, Matthew A. ;
Sandhu, Gurpreet S. ;
Gilkeson, Robert C. ;
Griswold, Mark A. ;
Gulani, Vikas .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) :W613-W620
[4]   Quantification and detectability of in-stent stenosis with CT angiography and MR angiography in arterial stents in vitro [J].
Blum, Melanie B. ;
Schmook, Maria ;
Schernthaner, Ruediger ;
Edelhauser, Gundula ;
Puchner, Stefan ;
Lammer, Johannes ;
Funovics, Martin A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (05) :1238-1242
[5]  
Byrne JV., 2012, EJMINT, V1225000057, P29
[6]  
Cashen TA, 2006, AM J NEURORADIOL, V27, P822
[7]   Time-Resolved 3D Contrast-Enhanced MRA on 3.0T: a Non-Invasive Follow-Up Technique after Stent-Assisted Coil Embolization of the Intracranial Aneurysm [J].
Choi, Jin Woo ;
Roh, Hong Gee ;
Moon, Won-Jin ;
Kim, Na Ra ;
Moon, Sung Gyu ;
Kang, Chung Hwan ;
Chun, Young Il ;
Kang, Hyun-Seung .
KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (06) :662-670
[8]   Cranial Dural Arteriovenous Fistula: Diagnosis and Classification with Time-Resolved MR Angiography at 3T [J].
Farb, R. I. ;
Agid, R. ;
Willinsky, R. A. ;
Johnstone, D. M. ;
terBrugge, K. G. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (08) :1546-1551
[9]   Balloon-in-stent technique for the constructive endovascular treatment of "ultra-wide necked" circumferential aneurysms [J].
Fiorella, D ;
Albuquerque, FC ;
Masaryk, TJ ;
Rasmussen, PA ;
McDougall, CG .
NEUROSURGERY, 2005, 57 (06) :1218-1226
[10]   Usefulness of the neuroform stent for the treatment of cerebral aneurysms: Results at initial (3-6-mo) follow-up [J].
Fiorella, D ;
Albuquerque, FC ;
Deshmukh, VR ;
McDougall, CG .
NEUROSURGERY, 2005, 56 (06) :1191-1201