Analytical challenges in doping control: Comprehensive two-dimensional gas chromatography with time of flight mass spectrometry, a promising option

被引:48
作者
Silva, A. I., Jr. [1 ,2 ]
Pereira, H. M. G. [1 ]
Casilli, A. [3 ]
Conceicao, F. C. [1 ]
Aquino Neto, F. R. [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Quim, LAB DOP LADETEC, BR-21941909 Rio De Janeiro, Brazil
[2] Cefet Quim, Rio De Janeiro, Brazil
[3] Univ Messina, Fac Farm, Dipartimento Farmacochim, Messina, Italy
关键词
Comprehensive two-dimensional gas chromatography; Time of flight mass spectrometry; Doping control; Anabolic agents; 3 '-Hydroxystanozolol; GC X GC; ANABOLIC-STEROIDS; SPECIAL EMPHASIS; SCREENING METHOD; LIQUID; IMPROVEMENTS; URINE; DRUGS;
D O I
10.1016/j.chroma.2008.10.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Doping control screening based on the enhanced resolution of comprehensive two-dimensional (2D) gas chromatography hyphenated to time of flight mass spectrometer was investigated. The identification of anabolic agents (clenbuterol, norandrosterone, epimetendiol, two nnethyltestosterone metabolites and 3'-hydroxystanozolol) contained in a spiked urine sample (2 ng/ml) was demonstrated. Special emphasis was given to 3'-hydroxystanozolol, mainly considering the difficulty in its detection. In contrast to conventional GC-MS approaches that must use single-ion monitoring, the GC x GC-TOFMS method enabled the identification of that metabolite through the deconvolution of the full mass spectrum and also resolved the co-eluted peaks of 3'-hydroxystanozolol and an endogenous component. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:2913 / 2922
页数:10
相关论文
共 26 条
[1]   Recent developments in comprehensive two-dimensional gas chromatography (GC X GC) I. Introduction and instrumental set-up [J].
Adahchour, M. ;
Beens, J. ;
Vreuls, R. J. J. ;
Brinkman, U. A. Th .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (05) :438-454
[2]   Testing for natural and synthetic anabolic agents in human urine [J].
Ayotte, C ;
Goudreault, D ;
Charlebois, A .
JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (01) :3-25
[3]  
Beens J, 1998, HRC-J HIGH RES CHROM, V21, P47
[4]  
de Geus HJ, 1998, HRC-J HIGH RES CHROM, V21, P411
[5]   GC x GC - A new analytical tool for environmental forensics [J].
Frysinger, GS ;
Gaines, RB ;
Reddy, CM .
ENVIRONMENTAL FORENSICS, 2002, 3 (01) :27-34
[6]   Preventive doping control analysis: liquid and gas chromatography time-of-flight mass spectrometry for detection of designer steroids [J].
Georgakopoulos, Costas G. ;
Vonaparti, Ariadni ;
Stamou, Marianna ;
Kiousi, Polyxeni ;
Lyris, Emmanouil ;
Angelis, Yiannis S. ;
Tsoupras, George ;
Wuest, Bernhard ;
Nielen, Michel W. F. ;
Panderi, Irene ;
Koupparis, Michalis .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (15) :2439-2446
[7]  
Geyer H., 1997, RECENT ADV DOPING AN, P99
[8]   Shape selectivity: A key factor in comprehensive two-dimensional gas chromatographic analysis of toxic PCBs [J].
Haglund, P ;
Harju, M ;
Ong, R ;
Marriott, P .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (07) :306-311
[9]   Improvement in steroid screening for doping control with special emphasis on stanozolol [J].
Huenerbein, A ;
Marques, MAS ;
Pereira, AD ;
Neto, FRD .
JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) :375-386
[10]   Rapid screening of doping agents in human urine by vacuum MALDI-Linear ion trap mass spectrometry (vol 79, pg 6020, 2007) [J].
Kosanam, H. ;
Prakash, P. K. Sai ;
Yates, C. R. ;
Miller, D. D. ;
Ramagiri, S. .
ANALYTICAL CHEMISTRY, 2007, 79 (21) :8420-8420