INFLUENCE OF GROUNDING RESISTANCE ON EFFECTIVENESS OF LIGHTNING PROTECTION FOR POWER DISTRIBUTION LINES WITH SURGE ARRESTERS

被引:0
|
作者
Takahashi, Akihisa [1 ]
Furukawa, Seiji [1 ]
Ishimoto, Kazuyuki [1 ]
Asakawa, Akira [1 ]
Hidaka, Tetsuya [2 ]
机构
[1] CRIEPI, Tokyo, Japan
[2] Chugoku Elect Power Co Inc, Hiroshima, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We clarified the influence of grounding resistance on the effectiveness of lightning protection for power distribution lines with a ground wire (GW) and surge arresters (SAs) by EMTP analysis and experiments. The results indicated that power distribution lines with both a GW and SAs can increase the lightning protection level against direct hits without lowering the grounding resistance compared with using only SAs. A cost reduction and the improvement of the electric supply reliability can be expected by exchanging part of the grounding cost with the installation of a lot of lightning protection devices on power distribution lines.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] THE LIGHTNING PERFORMANCE OF OVERHEAD DISTRIBUTION LINE INSTALLED MOV AND CLAH SURGE ARRESTERS
    Thanasaksiri, T.
    INTERNATIONAL CONFERENCE ON POWER CONTROL AND OPTIMIZATION, 2008, 1052 : 25 - 29
  • [42] Influence of lightning surge on photovoltaics considering LPZ protection level and IEC-60364 grounding system
    Cho J.-Y.
    Kim K.-H.
    Lee J.-K.
    Woo J.-W.
    Transactions of the Korean Institute of Electrical Engineers, 2019, 68 (11): : 1288 - 1291
  • [43] Response of distribution networks to direct and indirect lightning: Influence of surge arresters location, flashover occurrence and environmental shielding
    Borghetti, Alberto
    Napolitano, Fabio
    Nucci, Carlo Alberto
    Tossani, Fabio
    ELECTRIC POWER SYSTEMS RESEARCH, 2017, 153 : 73 - 81
  • [44] Overview of IEC Standards' recommendations for lightning protection of electrical high-voltage power systems using surge arresters
    Hinrichsen, Volker
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1701 - 1707
  • [45] Surge impedance of a grounding lead conductor along a concrete pole in power distribution lines
    Sekioka, S.
    Mozumi, T.
    Ametani, A.
    Proceedings of the Universities Power Engineering Conference, 2000,
  • [46] Lightning protection method for transmission lines based on power grid lightning hazard distribution
    North China Grid Company Limited, Beijing 100053, China
    不详
    Gaodianya Jishu, 2008, 10 (2065-2069):
  • [48] A Detection Method of Lightning Damaged Distribution Surge Arresters Using Discharge Current Waveforms
    Matsuura, Susumu
    Kanatani, Kenichi
    Sugimoto, Hitoshi
    IEEJ Transactions on Power and Energy, 2023, 143 (12) : 659 - 666
  • [49] FDTD Analysis of Metal Oxide Surge Arresters for Protection of Multiconductor Transmission Lines
    Stracqualursi, Erika
    Araneo, Rodolfo
    Lovat, Giampiero
    Burghignoli, Paolo
    PROCEEDINGS OF THE 2020 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2020,
  • [50] Study of lightning protection of power distribution lines located in mountainous areas
    Lightning Res. and Consulting Center, Hokuriku Electric Power Company, Toyama 930-0848, Japan
    不详
    不详
    不详
    Proc IEEE Power Eng Soc Trans Distrib Conf, 1600, ASIA PACIFIC (677-682):