Optimizing the evaluation of thermal transmittance with the thermometric method using multilayer perceptrons

被引:23
作者
Bienvenido-Huertas, David [1 ]
Rubio-Bellido, Carlos [2 ]
Luis Perez-Ordonez, Juan [3 ]
Moyano, Juan [1 ]
机构
[1] Univ Seville, Dept Graph Express & Bldg Engn, E-41012 Seville, Spain
[2] Univ Seville, Dept Bldg Construct 2, E-41012 Seville, Spain
[3] Univ A Coruna, Dept Civil Engn, ETSI Caminos Canales & Puertos, Campus Elvina S-N, La Coruna 15071, Spain
关键词
Thermal transmittance; ISO; 9869-1; Thermometric method; Multilayer perceptrons; IN-SITU MEASUREMENT; EXCESS WINTER DEATHS; INFRARED THERMOGRAPHY; BUILDING ENVELOPE; U-VALUE; FUEL POVERTY; RESISTANCE; DESIGN; VALUES; PARAMETERS;
D O I
10.1016/j.enbuild.2019.06.040
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The characterization of building thermal behaviour is crucial to achieve the low-carbon objectives of the European Union by 2050. In this way, the knowledge of the thermal transmittance is being developed as a significant factor of the thermophysical properties of the envelope. In the existing building, the theoretical calculation has several limitations with non-destructive techniques typical of the deterioration of the elements. Many experimental methods obtain therefore more representative results. The experimental method developed in ISO 9869-1 is the most standardized, although it presents limitations in the heat flux measurement. However, the thermometric method obtains the thermal transmittance with the surface temperature. This research is focused on the evaluation of the thermal transmittance based on ISO 9869-1 (average method and average method with correction for storage effects), but using variables measured with the thermometric method. For this purpose, multilayer perceptrons were used as post-processing techniques. The models were trained by using a dataset of 22,820 simulated tests of representative walls of the building stock in Spain. The determination coefficient was greater than 98% in both analysis approaches. Individual models were also generated for each building period because they significantly influenced the input variables. The results showed that thermal transmittance values can be obtained without measuring the heat flux, and the error associated with the use of tabulated values for the total internal heat transfer can be removed. This research would guarantee a high assessment tax of buildings establishing adequate energy conservation measures to improve their energy performance. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:395 / 411
页数:17
相关论文
共 83 条
  • [1] Adhikari R, 2012, PLEA2012 C OPP LIM N
  • [2] In situ measurement of thermal transmittance and thermal resistance of hollow reinforced precast concrete walls
    Ahmad, Aftab
    Maslehuddin, Mohammed
    Al-Hadhrami, Luai M.
    [J]. ENERGY AND BUILDINGS, 2014, 84 : 132 - 141
  • [3] A comprehensive experimental approach for the validation of quantitative infrared thermography in the evaluation of building thermal transmittance
    Albatici, Rossano
    Tonelli, Arnaldo M.
    Chiogna, Michela
    [J]. APPLIED ENERGY, 2015, 141 : 218 - 228
  • [4] Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site
    Albatici, Rossano
    Tonelli, Arnaldo M.
    [J]. ENERGY AND BUILDINGS, 2010, 42 (11) : 2177 - 2183
  • [5] A New Metre for Cheap, Quick, Reliable and Simple Thermal Transmittance (U-Value) Measurements in Buildings
    Andujar Marquez, Jose Manuel
    Martinez Bohorquez, Miguel Angel
    Gomez Melgar, Sergio
    [J]. SENSORS, 2017, 17 (09):
  • [6] [Anonymous], 6946 ISO
  • [7] [Anonymous], 1994, ADV MOLDING ANAL
  • [8] [Anonymous], 2011, OFF J EUR UNION
  • [9] [Anonymous], 2017, FIN EN CONS SECT FUE
  • [10] [Anonymous], REV CONSTR