Intraoperative compensation of magnetic field distortions for fluoroscopic and electromagnetic hybrid navigation

被引:3
作者
Cavaliere, Marco [1 ,2 ]
Cantillon-Murphy, Padraig [1 ,2 ]
机构
[1] Univ Coll Cork, Sch Engn, Coll Rd, Cork, Ireland
[2] Tyndall Natl Inst, Cork, Ireland
基金
爱尔兰科学基金会; 欧洲研究理事会;
关键词
Electromagnetic tracking; Fluoroscopy; Hybrid navigation; Calibration; Magnetic field modelling; TRACKING;
D O I
10.1007/s11548-022-02663-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Hybrid navigation is a promising technique which combines the benefits of optical or electromagnetic tracking (EMT) and fluoroscopy imaging. Unfortunately, the fluoroscopy system is a source of metallic distortion for the EMT system. In this work, we present a new method for intraoperative calibration and real-time compensation of dynamic field distortions. The method was tested in the presence of a fluoroscopy C-arm, and sub-millimetre errors were obtained after distortion correction. Methods A hybrid navigation scenario was created by combining the open-source electromagnetic tracking system Anser EMT and a commercial fluoroscopy C-arm. The electromagnetic field generator was placed directly on top of the X-ray collimator, which introduced significant field distortion. Magnetic sensors were placed at known positions to capture the magnetic distortion, and virtual magnetic dipole sources were used to model the distortion magnetic field. The accuracy of the compensated EMT model was tested on a grid of test points. Results Error reduction was demonstrated from 12.01 to 0.35 mm and from 25.03 to 0.49 mm, for horizontal and vertical sensor orientations, respectively, over a volume of 16 x 16 x 6 cm. It is proposed that such sub-millimetre tracking errors meet the needs of most endoscopic navigation tasks. Conclusions We describe a method to model a magnetic field in real time, based on redundant electromagnetic field measurements, and we apply it to compensate for the distortion introduced by a fluoroscopy C-arm. The main limitation of the approach is the requirement for a high number of sensors, with possible occlusion of the operative space. Solutions might come from miniaturisation and wireless sensing.
引用
收藏
页码:1717 / 1721
页数:5
相关论文
共 8 条
[1]  
[Anonymous], AURORA SENSORSND
[2]  
[Anonymous], POLARIS VEGANDI
[3]   Electromagnetic Tracking in Medicine-A Review of Technology, Validation, and Applications [J].
Franz, Alfred M. ;
Haidegger, Tamas ;
Birkfellner, Wolfgang ;
Cleary, Kevin ;
Peters, Terry M. ;
Maier-Hein, Lena .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (08) :1702-1725
[4]   Anser EMT: the first open-source electromagnetic tracking platform for image-guided interventions [J].
Jaeger, Herman Alexander ;
Franz, Alfred Michael ;
O'Donoghue, Kilian ;
Seitel, Alexander ;
Trauzettel, Fabian ;
Maier-Hein, Lena ;
Cantillon-Murphy, Padraig .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (06) :1059-1067
[5]   CycleGAN for interpretable online EMT compensation [J].
Krumb, Henry ;
Das, Dhritimaan ;
Chadda, Romol ;
Mukhopadhyay, Anirban .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2021, 16 (05) :757-765
[6]  
Ramachandran B, 2016, US Patent, Patent No. [9,522,045, 9522045]
[7]   Simultaneous Electromagnetic Tracking and Calibration for Dynamic Field Distortion Compensation [J].
Sadjadi, Hossein ;
Hashtrudi-Zaad, Keyvan ;
Fichtinger, Gabor .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (08) :1771-1781
[8]   Research on Intraoperative Organ Motion Tracking Method Based on Fusion of Inertial and Electromagnetic Navigation [J].
Zhang, Yongde ;
Wang, Kairui ;
Jiang, Jingang ;
Tan, Qiyun .
IEEE ACCESS, 2021, 9 :49069-49081