High-capacity multimodal anion-exchange membranes for polishing of therapeutic proteins

被引:10
作者
Osuofa, Joshua [1 ]
Henn, Daniel [2 ]
Zhou, Jinxiang [2 ]
Forsyth, Anna [2 ]
Husson, Scott M. [1 ]
机构
[1] Clemson Univ, Dept Chem & Biomol Engn, Clemson, SC 29634 USA
[2] Purilogics LLC, Greenville, SC USA
基金
美国国家卫生研究院;
关键词
downstream processing; mixed-mode chromatography; salt-tolerant; single-use chromatography; viral vector purification; CHROMATOGRAPHY; PURIFICATION;
D O I
10.1002/btpr.3129
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This contribution reports on a study using Purexa (TM)-MQ multimodal anion-exchange (AEX) membranes for protein polishing at elevated solution conductivities. Dynamic binding capacities (DBC10) of bovine serum albumin (BSA), human immunoglobulins, and salmon sperm DNA (ss-DNA) are reported for various salt types, salt concentrations, flowrates, and pH. Using 1 mg/ml BSA, DBC10 values for Purexa (TM)-MQ were >90 mg/ml at conductivities up to 15 mS/cm. The membranes maintained a high, salt-tolerant BSA DBC10 of 89.8 +/- 2.7 (SD) over the course of 100 bind-elute cycles. Polishing studies with acidic and basic monoclonal antibodies at >2 kg/L loads showed that Purexa (TM)-MQ had higher clearance of host cell proteins and aggregate species at high conductivity (13 mS/cm) and in the presence of phosphate than other commercial AEX media. Purexa (TM)-MQ also had a high ss-DNA DBC10 of 50 mg/ml at conductivities up to 15 mS/cm, markedly outperforming other commercial products. In addition to the effectiveness of Purexa (TM)-MQ for protein polishing at elevated solution conductivities, its unusually high binding capacity for ss-DNA indicates potential applications for plasmid DNA purification.
引用
收藏
页数:11
相关论文
共 50 条
[31]   Determination of neomycin sulfate and impurities using high-performance anion-exchange chromatography with integrated pulsed amperometric detection [J].
Hanko, Valoran P. ;
Rohrer, Jeffrey S. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (01) :131-141
[32]   High-performance purification of gelsolin from plasma using anion-exchange porous hollow-fiber membrane [J].
Hagiwara, K ;
Yonedu, S ;
Saito, K ;
Shiraishi, T ;
Sugo, T ;
Tojyo, T ;
Katayama, E .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 821 (02) :153-158
[33]   Application of high-performance anion-exchange chromatography with pulsed amperometric detection to compare the kinetic properties of β-glucosidase on oligosaccharides from lichenase digested barley β-glucan [J].
Radva, Daniel ;
Knutsen, Svein Halvor ;
Kosary, Judit ;
Ballance, Simon .
CARBOHYDRATE RESEARCH, 2012, 358 :56-60
[34]   Carbohydrate and alditol analysis by high-performance anion-exchange chromatography coupled with electrochemical detection at a cobalt-modified electrode [J].
Innocenzo G. Casella ;
Michela Contursi .
Analytical and Bioanalytical Chemistry, 2003, 376 :673-679
[35]   Carbohydrate and alditol analysis by high-performance anion-exchange chromatography coupled with electrochemical detection at a cobalt-modified electrode [J].
Casella, IG ;
Contursi, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (05) :673-679
[36]   Evaluation of high-capacity cation exchange chromatography for direct capture of monoclonal antibodies from high-titer cell culture processes [J].
Tao, Yinying ;
Ibraheem, Aladein ;
Conley, Lynn ;
Cecchini, Douglas ;
Ghose, Sanchayita .
BIOTECHNOLOGY AND BIOENGINEERING, 2014, 111 (07) :1354-1364
[37]   Functionalization of magnetic nanoparticles with high-binding capacity for affinity separation of therapeutic proteins [J].
Masthoff, Ingke-Christine ;
David, Florian ;
Wittmann, Christoph ;
Garnweitner, Georg .
JOURNAL OF NANOPARTICLE RESEARCH, 2013, 16 (01)
[38]   High-Capacity Strong Cation Exchange Resin Based on Reutilization of An Inactivated Immobilized Enzyme and Its Adsorption Properties for Lysozyme [J].
Yuan Jing-Xiang ;
Wang Chao-Zhan ;
Wei Yin-Mao .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (12) :1892-1899
[39]   Rapid high-performance liquid chromatographic analysis of adenovirus type 5 particles with a prototype anion-exchange analytical monolith column [J].
Whitfield, Robert J. ;
Battom, Suzanne E. ;
Barut, Milos ;
Gilham, David E. ;
Ball, Philip D. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (13) :2725-2729
[40]   Automated flow-based anion-exchange method for high-throughput isolation and real-time monitoring of RuBisCO in plant extracts [J].
Suarez, Ruth ;
Miro, Manuel ;
Cerda, Victor ;
Alejandro Perdomo, Juan ;
Galmes, Jeroni .
TALANTA, 2011, 84 (05) :1259-1266