The detection of platelet derived growth factor using decoupling of quencher-oligonucleotide from aptamer/quantum dot bioconjugates

被引:42
作者
Kim, Gang-Il [2 ]
Kim, Kyung-Woo [1 ]
Oh, Min-Kyu [1 ]
Sung, Yun-Mo [2 ]
机构
[1] Korea Univ, Dept Chem & Biol Engn, Seoul 136713, South Korea
[2] Korea Univ, Dept Mat Sci & Engn, Seoul 136713, South Korea
关键词
QUANTUM-DOT; SEMICONDUCTOR CLUSTERS; GOLD NANOPARTICLES; ENERGY-TRANSFER; FLUORESCENCE; PROTEIN; NANOCRYSTALS; ANTIBODY;
D O I
10.1088/0957-4484/20/17/175503
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
High-sensitivity, high-specificity detection of platelet derived growth factor (PDGF)-BB was realized using the change in fluorescence resonance energy transfer (FRET) occurring between quantum dot (QD) donors and black hole quencher (BHQ) acceptors. CdSe/ZnS QD/mercaptoacetic acid (MAA)/PDGF aptamer bioconjugates were successfully synthesized using ligand exchange. Black hole quencher (BHQ)-bearing oligonucleotide molecules showing partial sequence matching to PDGF aptamer were attached to PDGF aptamers and photoluminescence (PL) quenching was obtained through FRET. By adding target PDGF-BB to the bioconjugates containing BHQs, PL recovery was detected due to detachment of BHQ-bearing oligonucleotide from the PDGF aptamer as a result of the difference in affinity to the PDGF aptamer. The detection limit of the sensor was similar to 0.4 nM and the linearity was maintained up to 1.6 nM in the PL intensity versus concentration curve. Measurement of PL recovery was suggested as a strong tool for high-sensitivity detection of PDGF-BB. Epidermal growth factor (EGF), the negative control molecule, did not contribute to PL recovery due to lack of binding affinity to the PDGF aptamers, which demonstrates the selectivity of the biosensor.
引用
收藏
页数:5
相关论文
共 24 条
  • [1] Semiconductor clusters, nanocrystals, and quantum dots
    Alivisatos, AP
    [J]. SCIENCE, 1996, 271 (5251) : 933 - 937
  • [2] The use of nanocrystals in biological detection
    Alivisatos, P
    [J]. NATURE BIOTECHNOLOGY, 2004, 22 (01) : 47 - 52
  • [3] Quantum dot - Aptamer conjugates for synchronous cancer imaging, therapy, and sensing of drug delivery based on Bi-fluorescence resonance energy transfer
    Bagalkot, Vaishali
    Zhang, Liangfang
    Levy-Nissenbaum, Etgar
    Jon, Sangyong
    Kantoff, Philip W.
    Langer, Robert
    Farokhzad, Omid C.
    [J]. NANO LETTERS, 2007, 7 (10) : 3065 - 3070
  • [4] Surface immobilization methods for aptamer diagnostic applications
    Balamurugan, Subramanian
    Obubuafo, Anne
    Soper, Steven A.
    Spivak, David A.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (04) : 1009 - 1021
  • [5] THE QUANTUM-MECHANICS OF LARGER SEMICONDUCTOR CLUSTERS (QUANTUM DOTS)
    BAWENDI, MG
    STEIGERWALD, ML
    BRUS, LE
    [J]. ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1990, 41 : 477 - 496
  • [6] Semiconductor nanocrystals as fluorescent biological labels
    Bruchez, M
    Moronne, M
    Gin, P
    Weiss, S
    Alivisatos, AP
    [J]. SCIENCE, 1998, 281 (5385) : 2013 - 2016
  • [7] (CdSe)ZnS core-shell quantum dots: Synthesis and characterization of a size series of highly luminescent nanocrystallites
    Dabbousi, BO
    RodriguezViejo, J
    Mikulec, FV
    Heine, JR
    Mattoussi, H
    Ober, R
    Jensen, KF
    Bawendi, MG
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1997, 101 (46) : 9463 - 9475
  • [8] Quantum dot-antibody and aptamer conjugates shift fluorescence upon binding bacteria
    Dwarakanath, S
    Bruno, JG
    Shastry, A
    Phillips, T
    John, A
    Kumar, A
    Stephenson, LD
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2004, 325 (03) : 739 - 743
  • [9] A hybrid quantum dot-antibody fragment fluorescence resonance energy transfer-based TNT sensor
    Goldman, ER
    Medintz, IL
    Whitley, JL
    Hayhurst, A
    Clapp, AR
    Uyeda, HT
    Deschamps, JR
    Lassman, ME
    Mattoussi, H
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (18) : 6744 - 6751
  • [10] Quantum-dot/aptamer-based ultrasensitive multi-analyte electrochemical biosensor
    Hansen, JA
    Wang, J
    Kawde, AN
    Xiang, Y
    Gothelf, KV
    Collins, G
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (07) : 2228 - 2229