Using Genetic Algorithm for Electrode Movement Problem in Electrical Impedance Tomography

被引:0
作者
Li, Xuefei [2 ]
Luo, Ciyong [1 ]
Wang, Ping [1 ]
Chen, Minyou [1 ]
He, Wei [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] CISDI Engn CO LTD, Chongqing 400013, Peoples R China
来源
2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3 | 2008年
关键词
Electrode Movement Problem; Electrical Impedance Tomography; Genetic Algorithm;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical Impedance Tomography (EIT) attempts to reconstruct the internal impedance distribution in a medium according to electrical measurements with electrodes on the medium surface. Main problem of EIT is the drift of electrodes during the medical applications, in which the body surface moves during breathing and posture change. In this paper, a new approach which can distinguish electrode movements from measurement data of EIT for eliminating such effects in static reconstructed image is presented. To achieve these objectives, this paper proposed a linear model to describe affection of boundary voltages caused by electrode movements. A genetic algorithm for the problems is introduced, which attempted to rind the optimization of electrode movements to match the measurement voltages. To get least number of iterations possible, we introduce cultivation process in mutation operator. Simulation experiments show that the genetic algorithm is efficient and effective for electrode movement problem.
引用
收藏
页码:1804 / +
页数:2
相关论文
共 20 条
  • [1] Impedance imaging of lung ventilation: Do we need to account for chest expansion?
    Adler, A
    Guardo, R
    Berthiaume, Y
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (04) : 414 - 420
  • [2] Electrical impedance tomography: Regularized imaging and contrast detection
    Adler, A
    Guardo, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (02) : 170 - 179
  • [3] [Anonymous], 1975, ADAPTATION NATURE AR
  • [4] Errors in reconstruction of resistivity images using a linear reconstruction technique
    Barber, D.C.
    Brown, B.H.
    [J]. Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 101 - 104
  • [5] Electrical impedance tomography with compensation for electrode positioning variations
    Blott, BH
    Daniell, GJ
    Meeson, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) : 1731 - 1739
  • [6] Data errors and reconstruction algorithms in electrical impedance tomography
    Breckon, W.R.
    Pidcock, M.K.
    [J]. Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 105 - 109
  • [7] A parametric model of the relationship between EIT and total lung volume
    Coulombe, N
    Gagnon, H
    Marquis, F
    Skrobik, Y
    Guardo, R
    [J]. PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) : 401 - 411
  • [8] Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities
    Frerichs, I
    [J]. PHYSIOLOGICAL MEASUREMENT, 2000, 21 (02) : R1 - R21
  • [9] Influence of changing peripheral geometry on electrical impedance tomography measurements
    Gersing, E
    Hofmann, B
    Osypka, M
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (05) : 359 - 361
  • [10] GREFENSTETTE JJ, 1999, IEEE T SYST MAN CYB, V216, P122