The Research on Measurement System and Method of Tissue Optical Parameters with Wide Spectra Based on Double-Integrating-Spheres

被引:0
作者
Han Lei [1 ]
Li Chen-xi [1 ,2 ]
Sun Cheng-tao [1 ]
Jiang Jing-ying [1 ]
Zhao Hui-juan [1 ,2 ]
Xu Ke-xin [1 ,2 ]
机构
[1] Tianjin Univ, Coll Precis Instruments & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
关键词
Double-integrating-spheres; Tissue optical parameters; Parameter correction; Multi-wavelength;
D O I
10.3964/j.issn.1000-0593(2016)02-0561-06
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The measurement of tissue optical parameters is the focusing research content of Biomedical Photonics. The optical properties of human tissue are closely related to the physiological and pathological state. In recent years, the tissue imaging diagnosis and non-invasive detection of componentsbecome the hot research topics, applying the tissue optical properties especially the absorption and scattering properties. These provide the basis for the study of optical imaging and the spectrum detection of body composition etc. The Double -Integrating -Spheres (DIS) method can measure the absorption coefficient, scattering coefficient and so on in vitro tissuesimultaneously. It has the advantages of accurate, rapid, large applicable scope. The method applya standard method for measuring the optical parameters. This paper build the wide spectrum measurement system of optical parameters based on DIS and super continuum lasers. Then we analyze the transfer function, error sources and the best measuring conditions of the system. Finally we establish the correction forward model based on BP-MCML and the inverse algorithm of the optical parameters based on L-M algorithm. The optical parameters of intralipid solution in the wavelength range of 1 100 similar to 1 400 nm are measured. The experiment results show that the improved inverse algorithm is accurate. The multiple measurements standard deviation is within 3%. Compared the results of scattering coefficient and absorption coefficient at different wavelengths to the results of other research groups, the deviation is less than 3. 4%.
引用
收藏
页码:561 / 566
页数:6
相关论文
共 14 条
[1]   Parallel computing with graphics processing units for high-speed Monte Carlo simulation of photon migration [J].
Alerstam, Erik ;
Svensson, Tomas ;
Andersson-Engels, Stefan .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (06)
[2]   A primary method for determination of optical parameters of turbid samples and application to intralipid between 550 and 1630nm [J].
Chen, Cheng ;
Lu, Jun Q. ;
Ding, Huafeng ;
Jacobs, Kenneth M. ;
Du, Yong ;
Hu, Xin-Hua .
OPTICS EXPRESS, 2006, 14 (16) :7420-7435
[3]   The effect of light losses in double integrating spheres on optical properties estimation [J].
de Vries, G ;
Beek, JF ;
Lucassen, GW ;
van Gemert, MJC .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :944-947
[4]   Influence of oxygen saturation on the optical scattering properties of human red blood cells in the spectral range 250 to 2000 nm [J].
Friebel, Moritz ;
Helfmann, Juergen ;
Netz, Uwe ;
Meinke, Martina .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (03)
[5]   Artificial neural network method for determining optical properties from double-integrating-spheres measurements [J].
Li, Chenxi ;
Zhao, Huijuan ;
Wang, Qiuyin ;
Xu, Kexin .
CHINESE OPTICS LETTERS, 2010, 8 (02) :173-176
[6]  
Liu Yang, 2003, NUMERICAL METHODS SY
[7]   Identification of Adulterated Milk Based on Two-Dimensional Correlation Near-Infrared Spectra Parameterization and BP Neural Network [J].
Miao Jing ;
Cao Yu-zhen ;
Yang Ren-jie ;
Liu Rong ;
Sun Hui-li ;
Xu Ke-xin .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (11) :3038-3041
[8]  
Tamara L. T., 2001, J BIOMED OPT, V6, P167
[9]  
Tangbing Guan, 2007, STUDY RECONSTRUCTION
[10]   MCML - MONTE-CARLO MODELING OF LIGHT TRANSPORT IN MULTILAYERED TISSUES [J].
WANG, LH ;
JACQUES, SL ;
ZHENG, LQ .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1995, 47 (02) :131-146