Scanning transmission ion microscopy tomography at the Leipzig nanoprobe LIPSION

被引:6
作者
Reinert, T
Sakellariou, A
Schwertner, M
Vogt, J
Butz, T
机构
[1] Univ Leipzig, Fak Phys & Geowissensch, D-04103 Leipzig, Germany
[2] Univ Melbourne, Sch Phys, Microanalyt Res Ctr, Melbourne, Vic 3010, Australia
关键词
ion microbeam; scanning transmission ion microscopy; tomography; subcellular; cartilage; collagen;
D O I
10.1016/S0168-583X(01)01186-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Scanning transmission ion microscopy (STIM) of joint cartilage Could visualise single collagen fibrils. Thus. answers to the controversial questions of their alignment could be given. However, the fibrils form three-dimensional structures that are not yet fully disclosed. STIM tomography is needed to give more detailed information. The size of the structures requires a challenging resolution of about 100 rim. The first STIM tomographic experiment has been performed at the Leipzig nanoprobe LIPSION. 360 projections of a cartilage sample (30 mum x 32 mum x 10 mum) were taken. The pixel resolution was 250 x 250 pixels for each projection. The data set was reconstructed at MARC Melbourne using the backprojection of filtered projections technique. The data show the feasibility of STIM tomography in cartilage research. However. experimental inaccuracies (rotational displacement and magnetic stray fields) have limited the resolution thus far. Improvements in the experimental set-up will lead to higher resolution. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:266 / 270
页数:5
相关论文
共 12 条
[1]  
ALBERTS B, 1995, MOLKULARBIOLOGIE ZEL
[2]   STIM TOMOGRAPHY - A 3-DIMENSIONAL HIGH-RESOLUTION IMAGING TOOL [J].
BENCH, G ;
SAINT, A ;
CHOLEWA, M ;
LEGGE, GJF ;
WEIRUP, DL ;
PONTAU, AE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 68 (1-4) :481-490
[3]   HIGH-RESOLUTION STIM [J].
BENCH, GS ;
LEGGE, GJF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 :655-658
[4]   The Leipzig high-energy ion nanoprobe:: A report on first results [J].
Butz, T ;
Flagmeyer, RH ;
Heitman, J ;
Jamieson, DN ;
Legge, GJF ;
Lehmann, D ;
Reibetanz, U ;
Reinert, T ;
Saint, A ;
Spemann, D ;
Szymanski, R ;
Tröger, W ;
Vogt, J ;
Zhu, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 161 :323-327
[5]  
ECHLIN P, 1999, LOW TEMPERATURE MICR
[6]   In vitro MR imaging of hyaline cartilage: Correlation with scanning electron microscopy [J].
Goodwin, DW ;
Zhu, HQ ;
Dunn, JF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :405-409
[7]  
Gwynn IA, 2000, J MICROSC-OXFORD, V197, P159
[8]   3D mapping of individual cells using a proton microbeam [J].
Michelet, C ;
Moretto, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 150 (1-4) :173-178
[9]   Visualisation of collagen fibrils in joint cartilage using STIM [J].
Reinert, T ;
Reibetanz, U ;
Vogt, J ;
Butz, T ;
Werner, A ;
Gründer, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 :511-515
[10]   Three-dimensional ion micro-tomography [J].
Sakellariou, A ;
Jamieson, DN ;
Legge, GJF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 :211-218