Diagnostic accuracy of viscoelastic point-of-care identification of hypofibrinogenaemia in cardiac surgical patients: A systematic review

被引:7
作者
Gibbs, Neville M. [1 ,2 ]
Weightman, William M. [1 ]
机构
[1] Sir Charles Gairdner Hosp, Dept Anaesthesia, Nedlands, WA 6009, Australia
[2] Univ Western Australia, Nedlands, WA, Australia
关键词
Fibrinogen; viscoelastic; thromboelastometry; thrombelastography; thromboelastography; point of care; accuracy; ROTATIONAL THROMBOELASTOMETRY; COAGULATION MANAGEMENT; FIBRINOGEN LEVELS; BLOOD-LOSS; SURGERY; METAANALYSIS; GUIDELINES; TESTS; ASSOCIATION; THROMBOCYTOPENIA;
D O I
10.1177/0310057X20948868
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Hypofibrinogenaemia during cardiac surgery may increase blood loss and bleeding complications. Viscoelastic point-ofcare tests provide more rapid diagnosis than laboratory measurement, allowing earlier treatment. However, their diagnostic test accuracy for hypofibrinogenaemia has never been reviewed systematically. We aimed to systematically review their diagnostic test accuracy for the identification of hypofibrinogenaemia during cardiac surgery. Two reviewers assessed relevant articles from seven electronic databases, extracted data from eligible articles and assessed quality. The primary outcomes were sensitivity, specificity and positive and negative predictive values. A total of 576 articles were screened and 81 full texts were assessed, most of which were clinical agreement or outcome studies. Only 10 diagnostic test accuracy studies were identified and only nine were eligible (ROTEMdelta 7; TEG5000 1; TEG6S 1, n = 1820 patients) (ROTEM, TEM International GmbH, Munich, Germany; TEG, Haemonetics, Braintree, MA, USA). None had a low risk of bias. Four ROTEM studies with a fibrinogen threshold less than 1.5-1.6 g/l and FIBTEM threshold A10 less than 7.5-8 mm had point estimates for sensitivity of 0.61-0.88; specificity 0.54-0.94; positive predictive value 0.42-0.70; and negative predictive value 0.74-0.98 (i.e. false positive rate 30%-58%; false negative rate 2%-26%). Two ROTEM studies with higher thresholds for both fibrinogen (<2 g/l) and FIBTEM A10 (<9.5 mm) had similar false positive rates (25%-46%), as did the two TEG studies (15%-48%). This review demonstrates that there have been few diagnostic test accuracy studies of viscoelastic point-of-care identification of hypofibrinogenaemia in cardiac surgical patients. The studies performed so far report false positive rates of up to 58%, but low false negative rates. Further diagnostic test accuracy studies of viscoelastic point-of-care identification of hypofibrinogenaemia are required to guide their better use during cardiac surgery.
引用
收藏
页码:339 / 353
页数:15
相关论文
共 85 条
[1]   DIAGNOSTIC-TESTS-2 - PREDICTIVE VALUES .4. [J].
ALTMAN, DG ;
BLAND, JM .
BRITISH MEDICAL JOURNAL, 1994, 309 (6947) :102-102
[3]  
[Anonymous], 2011, COCHRANE DATABASE SY
[4]  
[Anonymous], 2007, STAT GUID REP RES ST
[5]  
Arias-Morales Carlos E, 2017, F1000Res, V6, DOI 10.12688/f1000research.10085.1
[6]   Haemostatic management of cardiac surgical haemorrhage [J].
Besser, M. W. ;
Ortmann, E. ;
Klein, A. A. .
ANAESTHESIA, 2015, 70
[7]  
Bhardwaj V, 2017, ANN CARD ANAESTH, V20, P212, DOI 10.4103/aca.ACA_4_17
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   Roles of Thrombelastography and Thromboelastometry for Patient Blood Management in Cardiac Surgery [J].
Bolliger, Daniel ;
Tanaka, Kenichi A. .
TRANSFUSION MEDICINE REVIEWS, 2013, 27 (04) :213-220
[10]   Diagnosis - Comparative accuracy: assessing new tests against existing diagnostic pathways [J].
Bossuyt, PM ;
Irwig, L ;
Craig, J ;
Glasziou, P .
BRITISH MEDICAL JOURNAL, 2006, 332 (7549) :1089-1092