Rotor cage fault diagnosis in three-phase induction motors based on a current and virtual flux approach

被引:30
作者
Pires, Dulce F. [1 ]
Pires, V. Fernao [1 ,2 ]
Martins, J. F. [3 ]
Pires, A. J. [1 ,2 ,3 ]
机构
[1] Politecn Setubal, Escola Sup Tecnol Setubal Inst, Setubal, Portugal
[2] LabSEI Lab Sistemas Elect Ind, Setubal, Portugal
[3] Fac Ciencias & Tecnol UNL, CTS, Lisbon, Portugal
关键词
Induction motor; Diagnosis; Fault detection; Stator currents; Virtual flux; Rotor cage fault; BAR DETECTION; PROTECTION;
D O I
10.1016/j.enconman.2008.12.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper focuses on the detection of a rotor cage fault in a three-phase PWM feed induction motor. In inverter-fed machines there are some difficulties for the detection of a rotor cage fault. These difficulties are due to the fault signature that will be contained in the currents or voltages applied to the machine. In this way, a new approach based on the current and a virtual flux is proposed. The use of the virtual flux allows the improving of the signal to noise ratio. This approach also allows the identification of a rotor cage fault independently of the type of control used in the ac drive. The theoretical principle of this method is discussed. Simulation and experimental results are presented in order to show the effectiveness of the proposed approach. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1026 / 1032
页数:7
相关论文
共 18 条
[1]  
ALBERTO B, 2001, IEEE T IND APPL, V37
[2]   Novel approach based on microcontroller to online protection of induction motors [J].
Bayindir, Ramazan ;
Sefa, Ibrahim .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (03) :850-856
[3]  
Bellini A, 2003, IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES, PROCEEDINGS, P217
[4]   VIBRATION AND CURRENT MONITORING FOR DETECTING AIRGAP ECCENTRICITY IN LARGE INDUCTION-MOTORS [J].
CAMERON, JR ;
THOMSON, WT ;
DOW, AB .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1986, 133 (03) :155-163
[5]  
Cardoso AJM, 1995, IEEE IND APPLIC SOC, P642, DOI 10.1109/IAS.1995.530360
[6]   On line protection systems for induction motors [J].
Çolak, I ;
Çelik, H ;
Sefa, I ;
Demirbas, S .
ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (17) :2773-2786
[7]  
Cruz SMA, 2006, IEEE IND APPLIC SOC, P2346
[8]  
DISTER CJ, 1998, P IEEE IAS ANN M C S, V1, P312
[9]  
Drif M., 2006, 3rd IET International Conference on Power Electronics, Machines and Drives - PEMD, The Contarf Castle, Dublin, Ireland, 2006, P349
[10]  
HAKAN C, 2008, ENERG CONVERS MANAGE, V49, P854