Noise in flat-panel displays with subpixel structure

被引:26
作者
Badano, A
Gagne, RM
Jennings, RJ
Drilling, SE
Imhoff, BR
Muka, E
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20857 USA
[2] Marquette Univ, Milwaukee, WI 53201 USA
[3] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
liquid crystal display; medical display; noise; noise-power spectrum;
D O I
10.1118/1.1656529
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Subpixel structures found in medical monochrome active-matrix liquid crystal displays (AMLCDs) affect noise estimates measured with conventional methods. In this work, we discuss methods that identify sources of noise and permit the comparison of luminance noise estimates across technologies independent of pixel design and device technology. We used a three-million pixel AMLCD with a pixel structure consisting of three color stripes, each in a two-domain, in-plane switching mode. Images of uniform fields displayed on the AMLCD were acquired using a low-noise, high-resolution CCD camera. The camera noise and flat-field response were characterized using a uniform light source constructed for this purpose. We show results in terms of spatial luminance noise and noise power spectrum for high-resolution images and for the same images processed with a pixel-aligned aperture. We find that the pixel-aligned aperture eliminates almost all the noise found in the high-resolution images, suggesting that most of the luminance noise in AMLCDs comes from the subpixel structure and less-than-100% aperture ratio, rather than from interpixel variations. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:715 / 723
页数:9
相关论文
共 18 条
[1]   Method for measuring veiling glare in high-performance display devices [J].
Badano, A ;
Flynn, MJ .
APPLIED OPTICS, 2000, 39 (13) :2059-2066
[2]   Luminance effects on display resolution and noise [J].
Badano, A ;
Hipper, SJ ;
Jennings, RJ .
MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 :305-313
[3]  
BLUME H, 1991, P SID, V22, P355
[4]  
BLUME H, 1992, J SOC INF DISP, V25, P219
[5]  
BLUMENTHAL M, 1992, OPHTHALMIC SURG LAS, V23, P699
[6]  
CHEN J, 1995, J SOC INF DISP, V26, P868
[7]   High-fidelity electronic display of digital radiographs [J].
Flynn, MJ ;
Kanicki, J ;
Badano, A ;
Eyler, WR .
RADIOGRAPHICS, 1999, 19 (06) :1653-1669
[8]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[9]  
ICRU, 1995, 54 ICRU
[10]   Visual CRT sharpness estimation using a fiducial marker set [J].
Kohm, KS ;
Cameron, AW ;
Van Metter, RL .
MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 :286-297