共 15 条
Ultrafiltration enhanced by coagulation in an immersed membrane system
被引:54
作者:
Choksuchart, P
[1
]
Héran, M
[1
]
Grasmick, A
[1
]
机构:
[1] GSPA, Lab Genie Procedes Montpellier 2, F-34095 Montpellier 05, France
关键词:
ultrafiltration;
critical flux;
air injection;
immersed membrane;
coagulation;
D O I:
10.1016/S0011-9164(02)00421-6
中图分类号:
TQ [化学工业];
学科分类号:
0817 ;
摘要:
The aim of this study is to determinate optimum conditions, membrane configuration, air flow, coagulation rate, permeate flux, for the ultrafiltration of surface water. Results show how coagulation is a necessary pre-treatment to remove micro-particles in aqueous suspension (i) before a conventional sedimentation, (ii) before a membrane filtration. When membranes are immersed in a contactor, configuration allow to maintain the permeate flow rate at high value (200 L/h/m(2)/bar) mainly because coagulation induces large floc size. However, when the particle concentration of the suspension is very high (2 to 5 g/L), it is important to increase the shear stresses close to the immersed membrane to minimise a deposit set up on the surface. When no high cohesion forces exist between particles, the aeration, even under weak flow rate, allows to avoid this deposit making.
引用
收藏
页码:265 / 272
页数:8
相关论文