Ultrafiltration enhanced by coagulation in an immersed membrane system

被引:54
作者
Choksuchart, P [1 ]
Héran, M [1 ]
Grasmick, A [1 ]
机构
[1] GSPA, Lab Genie Procedes Montpellier 2, F-34095 Montpellier 05, France
关键词
ultrafiltration; critical flux; air injection; immersed membrane; coagulation;
D O I
10.1016/S0011-9164(02)00421-6
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The aim of this study is to determinate optimum conditions, membrane configuration, air flow, coagulation rate, permeate flux, for the ultrafiltration of surface water. Results show how coagulation is a necessary pre-treatment to remove micro-particles in aqueous suspension (i) before a conventional sedimentation, (ii) before a membrane filtration. When membranes are immersed in a contactor, configuration allow to maintain the permeate flow rate at high value (200 L/h/m(2)/bar) mainly because coagulation induces large floc size. However, when the particle concentration of the suspension is very high (2 to 5 g/L), it is important to increase the shear stresses close to the immersed membrane to minimise a deposit set up on the surface. When no high cohesion forces exist between particles, the aeration, even under weak flow rate, allows to avoid this deposit making.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 15 条
[1]   Removal of humic substances by UF and NF membrane systems [J].
Bian, R ;
Watanabe, Y ;
Tambo, N ;
Ozawa, G .
WATER SCIENCE AND TECHNOLOGY, 1999, 40 (09) :121-129
[2]   Microfiltration of activated sludge using submerged membrane with air bubbling (application to wastewater treatment) [J].
Bouhabila, EH ;
Ben Aim, R ;
Buisson, H .
DESALINATION, 1998, 118 (1-3) :315-322
[3]   How slug flow can improve ultrafiltration flux in organic hollow fibres [J].
Cabassud, C ;
Laborie, S ;
Laine, JM .
JOURNAL OF MEMBRANE SCIENCE, 1997, 128 (01) :93-101
[4]   Filtration of biomass with axial inter-fibre upward slug flow: performance and mechanisms [J].
Chang, S ;
Fane, AG .
JOURNAL OF MEMBRANE SCIENCE, 2000, 180 (01) :57-68
[5]   FLOCCULATION IN A FLUIDIZED-BED [J].
COMA, J ;
JABBOURI, A ;
GRASMICK, A ;
ELMALEH, S .
WATER RESEARCH, 1990, 24 (03) :361-366
[6]   The use of Dean vortices in coiled hollow-fibre ultrafiltration membranes for water and wastewater treatment [J].
Guiguia, C ;
Manno, P ;
Moulin, P ;
Clifton, MJ ;
Rouch, JC ;
Aptel, P ;
Laine, JM .
DESALINATION, 1998, 118 (1-3) :73-79
[7]   Coagulation of colloids in a boundary layer during cross-flow filtration [J].
Harmant, P ;
Aimar, P .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1998, 138 (2-3) :217-230
[8]   Prediction of cross-flow microfiltration through an inorganic tubular membrane with high-frequency retrofiltration [J].
Héran, M ;
Elmaleh, S .
CHEMICAL ENGINEERING SCIENCE, 2001, 56 (10) :3075-3082
[9]   Immersed membrane filtration for the production of drinking water: combination with PAC for NOM and SOCs removal [J].
Lebeau, T ;
Lelievre, C ;
Buisson, H ;
Cleret, D ;
Van de Venter, LW ;
Cote, P .
DESALINATION, 1998, 117 (1-3) :219-231
[10]   Removal of natural organic matter by ultrafiltration: Characterisation, fouling and cleaning [J].
Maartens, A ;
Swart, P ;
Jacobs, EP .
WATER SCIENCE AND TECHNOLOGY, 1999, 40 (09) :113-120