Performance optimization and analysis of solar combi-system with carbon dioxide heat pump

被引:29
作者
Deng, S.
Dai, Y. J. [1 ]
Wang, R. Z.
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
关键词
Solar heating; CO2 heat pump; Solar energy; Renewable energy;
D O I
10.1016/j.solener.2013.10.001
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a solar combi-system which consists of solar collectors and a carbon dioxide heat pump is proposed and investigated through simulation and optimization. Performance analysis and comparison are primarily conducted to show the feasibility and reasonability of using a CO2 heat pump as an auxiliary heater under local weather conditions. Then, a system model with a test building in TRNSYS is developed for performance optimization. The most influential variables are identified using influence and sensitivity analyzes of single parameters. Subsequently, a multi-parameter optimization using the high-weight parameters is carried out to obtain a final design result. The simulated results of the optimized case show that the average coefficient of performance of the CO2 heat pump is 2.38, and the solar fraction of the system is 69.0% for the entire heating season. The time when a comfortable temperature level can be achieved in the indoor environment accounts for 81.6% of the entire heating season. Furthermore, the performance characteristics of the proposed system are evaluated in terms of the thermal balance, fraction of the thermal energy saving, feasibility of net zero energy, economic factor, and CO2 emissions reduction. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:212 / 225
页数:14
相关论文
共 22 条
[1]  
Austin B.T., 2010, RENEW SUST ENERG REV, V15, P4013
[2]  
Beckman W.A., 2006, ENG EQUATION SOLVER
[3]  
Beijing Municipal Commission of Urban Planning, 2011, DES STAND E IN PRESS
[4]  
Caskey S., 2012, 2012 PURD C JUL 16 1
[5]   Natural working fluids for solar-boosted heat pumps [J].
Chaichana, C ;
Aye, L ;
Charters, WWS .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (06) :637-643
[6]  
China Meteorological Bureau, 2005, CHIN STAND WEATH DAT
[7]  
Duddumpudi V.S., 2010, THESIS U STRATHCLYDE
[8]  
Duffie J.A., 1991, Solar Engineering of Thermal Processes, Vsecond
[9]  
Ellehauge K., 2002, REPORT IEA SHS TASK
[10]   Comparison of CO2 heat pump water heater performance with baseline cycle and two high COP cycles [J].
Fernandez, Nicholas ;
Hwang, Yunho ;
Radermacher, Reinhard .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (03) :635-644