Voltammetric Analysis of Naproxen in Graphite Electrodes and Its Determination in Pharmaceutical Samples

被引:20
作者
Aguilar-Lira, G. Y. [1 ]
Alvarez Romero, G. A. [1 ]
Rojas-Hernandez, A. [2 ]
Paez-Hernandez, M. E. [1 ]
Rodriguez-Avila, J. A. [1 ]
Romero-Romo, M. A. [3 ]
机构
[1] Univ Autonoma Estado Hidalgo, Area Acad Quim, Mineral De La Reforma 42184, Hidalgo, Mexico
[2] Univ Autonoma Metropolitana Unidad Iztapalapa, Area Quim Anal, Mexico City 09340, DF, Mexico
[3] Univ Autonoma Metropolitana Azcapotzalco, Area Ingn Mat, Mexico City 02200, DF, Mexico
关键词
Differential pulse voltammetry; Naproxen; Pharmaceutical samples; Graphite electrode; FORMULATIONS;
D O I
10.1002/elan.201400119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present work discuses new findings in the electrochemistry of naproxen over graphite electrodes. This new approach, allows the proposal of a simple and competitive low-cost method to carry out naproxen's voltammetric quantification. Naproxen's indirect quantification through an adsorption anodic wave was performed at a graphite bar electrode using differential pulse voltammetry. An anodic current maximum was recorded at a potential of -0.3 V referred to a saturated Ag/AgCl reference electrode. The calibration plot having a correlation coefficient of 0.990, sensibility of 4.19 +/- 0.62 mu A cm(3) mu g(-1), with detection and quantification limits of 0.68 and 3.3 mu g cm(-3), respectively.
引用
收藏
页码:1573 / 1581
页数:9
相关论文
共 26 条
[1]   Determination of naproxen in pharmaceuticals by differential pulse voltammetry at a platinum electrode [J].
Adhoum, N ;
Monser, L ;
Toumi, M ;
Boujlel, K .
ANALYTICA CHIMICA ACTA, 2003, 495 (1-2) :69-75
[2]  
[Anonymous], 2003, 26 USP, P1273
[3]  
[Anonymous], 2011, FARMACOPEA ESTADOS U, P1
[4]   Continuous monitoring of Naproxen by a cytochrome P450-based electrochemical sensor [J].
Baj-Rossi, C. ;
Jost, T. Rezzonico ;
Cavallini, A. ;
Grassi, F. ;
De Micheli, G. ;
Carrara, S. .
BIOSENSORS & BIOELECTRONICS, 2014, 53 :283-287
[5]   OXIDATIVE DECARBOXYLATION OF NAPROXEN [J].
BOSCA, F ;
MARTINEZMANEZ, R ;
MIRANDA, MA ;
PRIMO, J ;
SOTO, J ;
VANO, L .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1992, 81 (05) :479-482
[6]  
Boynton C., 1998, J CLIN PHARMACOL, V6, P512
[7]   Determination of naproxen with chemiluminescence detection [J].
Campiglio, A .
ANALYST, 1998, 123 (07) :1571-1574
[8]   Direct and simultaneous spectrofluorometric determination of naproxen and salicylate in human serum assisted by chemometric analysis [J].
Damiani, PC ;
Borraccetti, MD ;
Olivieri, AC .
ANALYTICA CHIMICA ACTA, 2002, 471 (01) :87-96
[9]   Stereoselective determination of S-naproxen in tablets by capillary electrophoresis [J].
Fillet, M ;
Fotsing, L ;
Bonnard, J ;
Crommen, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) :799-805
[10]   ULTRAVIOLET SPECTROPHOTOMETRIC PROCEDURE FOR THE ROUTINE DETERMINATION OF NAPROXEN [J].
HOLZBECHER, M ;
ELLENBERGER, HA ;
MARSH, JM ;
BOUDREAU, S .
CLINICAL BIOCHEMISTRY, 1979, 12 (02) :66-67