Construct failure after open reduction and plate fixation of displaced midshaft clavicular fractures

被引:31
作者
Meeuwis, M. A. [1 ]
ter Gunne, A. F. Pull [1 ]
Verhofstad, M. H. J. [2 ]
van der Heijden, F. H. W. M. [1 ]
机构
[1] St Elizabeth Hosp, Dept Surg, POB 90151, NL-5000 LC Tilburg, Netherlands
[2] Univ Med Ctr Rotterdam, Erasmus MC, Dept Surgery Traumatol, POB 2040, NL-3000 CA Rotterdam, Netherlands
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2017年 / 48卷 / 03期
关键词
Clavicular fractures; Construct failure; Reconstruction plate; Locking compression plate; EPIDEMIOLOGY;
D O I
10.1016/j.injury.2017.01.040
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Worldwide, implants mostly used for fixation of displaced midshaft clavicular fractures (DMCF) are the easily to bend reconstruction plate and the stiffer small fragment locking compression plate. Construct failure rates after plate fixation of DMCF are reported around 5 percent. Possible risk factors for construct failure are implant type and fracture type. However, little is known about the influence of fracture fixation method on construct failure. The aim of this study was to assess construct failure in plate fixation of DMCF and to identify possible risk factors. Methods: All consecutive patients treated in a level 1 trauma centre with open reduction and fixation of DMCF using a 3.5-mm reconstruction plate or 3.5-mm small fragment locking compression plate between 2007 and 2015 were evaluated. Potential risk factors for construct failure were analysed using univariate analysis. Results: Two hundred and fifty-nine patients were analysed. Fifty DMCF (19%) were fixated with a reconstruction plate and 209 (81%) with a small fragment locking compression plate. Construct failure was seen in 18 patients (6.9%), including 5 broken plates and 13 with screw loosening. Eight percent of all reconstruction plates broke in contrast to 0.5 percent of all small fragment locking compression plates (p = 0.001). All broken implants were used as a bridging plate. Loosening of screws was seen in older patients and when the plate was fixated with less than three bicortical screws on one side of the fracture (p = 0.002). Conclusions: Overall construct failure after open reduction and plate fixation of DMCF occurred in 6.9 percent. Risk factors for plate breakage were the use of a reconstruction plate and a bridging method for fracture fixation. Risk factors for screw loosening were an increasing patient age and plate fixation with less than three bicortical screws on one side of the fracture. Recommendations: Based on the results of this study our recommendation is to use a small fragment locking compression plate for open reduction and internal fixation of DMCF. The surgeon should always strive to fixate the plate on both sides of the fracture with at least three bicortical screws. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:715 / 719
页数:5
相关论文
共 18 条
[1]   Single, Superiorly Placed Reconstruction Plate Compared with Flexible Intramedullary Nailing for Midshaft Clavicular Fractures A Prospective, Randomized Controlled Trial [J].
Andrade-Silva, Fernando Brandao ;
Kojima, Kodi Edson ;
Joeris, Alexander ;
Silva, Jorge Santos ;
Mattar, Rames .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (08) :620-626
[2]   Reoperation following open reduction and plate fixation of displaced mid-shaft clavicle fractures [J].
Ashman, Bradley D. ;
Slobogean, Gerard P. ;
Stone, Trevor B. ;
Viskontas, Darius G. ;
Moola, Farhad O. ;
Perey, Bertrand H. ;
Boyer, Dory S. ;
McCormack, Robert G. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (10) :1549-1553
[3]   Biomechanical comparison of the Locking Compression superior anterior clavicle plate with seven and ten hole reconstruction plates in midshaft clavicle fracture stabilisation [J].
Eden, Lars ;
Doht, Stefanie ;
Frey, Soenke P. ;
Ziegler, Dirk ;
Stoyhe, Jan ;
Fehske, Kai ;
Blunk, Torsten ;
Meffert, Rainer H. .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (12) :2537-2543
[4]   Locking plate osteosynthesis of clavicle fractures: complication and reoperation rates in one hundred and five consecutive cases [J].
Fridberg, Marie ;
Ban, Ilija ;
Issa, Zaid ;
Krasheninnikoff, Michael ;
Troelsen, Anders .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (04) :689-692
[5]   Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study [J].
Gilde, Alex K. ;
Jones, Clifford B. ;
Sietsema, Debra L. ;
Hoffmann, Martin F. .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9
[6]   Effects of plate location and selection on the stability of midshaft clavicle osteotomies: A biomechanical study [J].
Iannotti, MR ;
Crosby, LA ;
Stafford, P ;
Grayson, G ;
Goulet, R .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (05) :457-462
[7]   Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures - A multicenter, randomized clinical trial [J].
McKee, Michael D. ;
Kreder, Hans J. ;
Mandel, Scott ;
McCormack, Robert ;
Reindl, Rudolph ;
Pugh, David M. W. ;
Sanders, David ;
Buckley, Richard .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (01) :1-10
[8]  
NORDQVIST A, 1994, CLIN ORTHOP RELAT R, P127
[9]   Epidemiology of clavicle fractures [J].
Postacchini, F ;
Gumina, S ;
De Santis, P ;
Albo, F .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (05) :452-456
[10]   Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation [J].
Prasarn, Mark L. ;
Meyers, Kathleen N. ;
Wilkin, Geoffrey ;
Wellman, David S. ;
Chan, Daniel B. ;
Ahn, Jaimo ;
Lorich, Dean G. ;
Helfet, David L. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (12) :1655-1662