共 36 条
Quantum dot nanobead-based multiplexed immunochromatographic assay for simultaneous detection of aflatoxin B1 and zearalenone
被引:134
作者:
Shao, Yanna
[1
,2
]
Duan, Hong
[1
,2
]
Guo, Liang
[1
,3
]
Leng, Yuankui
[2
]
Lai, Weihua
[1
,2
]
Xiong, Yonghua
[1
,2
,3
]
机构:
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
[2] Nanchang Univ, Sch Food Sci, Nanchang 330047, Jiangxi, Peoples R China
[3] Nanchang Univ, Jiangxi OAI Joint Res Inst, Nanchang 330047, Jiangxi, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Immunochromatographic assay;
Multiplexed;
Quantum dot nanobead;
Streptavidin-biotin system;
LINKED-IMMUNOSORBENT-ASSAY;
BETA-AGONIST RESIDUES;
FLOW TEST STRIP;
QUANTITATIVE DETECTION;
SILICA NANOPARTICLES;
SENSITIVE DETECTION;
RAPID DETECTION;
MYCOTOXINS;
SAMPLES;
MS/MS;
D O I:
10.1016/j.aca.2018.03.041
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Immunochromatographic assay (ICA) is a promising technology for on-site detection. Nonetheless, the wide-scale application of ICA is hindered by several disadvantages, such as poor reproducibility, low sensitivity, and single-target detection. Thus, a novel quantum dot nanobead (QB)-based multiplexed ICA (QB-ICA) with multiple test lines was developed in this study for the simultaneous quantitative detection of aflatoxin B-1 (AFB(1)) and zearalenone (ZEN), where QBs with high luminescence were used as labels to enhance the analytical sensitivity of the ICA. Moreover, a streptavidin (SA)-biotin system, which was undisturbed by the target mycotoxins, was introduced as the signal output for the control line. Consequently, stable and reliable T/C values (ratios of signals on the test line to that of the control line) were obtained as quantitative signals. The proposed QB-ICA demonstrated high sensitivity for the simultaneous detection of AFB1 and ZEN, of which the half-maximal inhibitory concentrations reached as low as 38.98 pg mL(-1) and 1.23 ng mL(-1), respectively. At 10% competitive inhibition concentration, the limit detections (LOD) were 1.65 and 59.15 pg mL(-1) for AFB1 and ZEN, respectively. The average recoveries of the intra-and inter-assays ranged from 81.77% to 119.70% and from 94.18% to 111.4% for AFB(1) and ZEN quantification, respectively, and the variation coefficients were less than 12%, thereby indicating that the proposed method is highly accurate and robust. These findings suggest that QB-ICA using SA-biotin system as the signal output of control line is an excellent point-of-care platform for the rapid screening of mycotoxins. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:163 / 171
页数:9
相关论文