Ultrasound-guided placement of central venous catheters: a comprehensive guide for the clinician

被引:0
作者
Steenvoorden, T. S. [1 ,3 ]
Smit, J. M. [2 ,3 ,4 ]
Matta, J. Lopez [5 ,6 ]
van Westerloo, D. J. [5 ,6 ]
Tuinman, P. R. [2 ,3 ,4 ,6 ]
机构
[1] OLVG, Dept Intens Care Med, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Intens Care Med, Amsterdam UMC, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Amsterdam UMC, Res VUmc Intens Care REVIVE, Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, Amsterdam UMC, Inst Cardiovasc Res ICAR VU, Amsterdam, Netherlands
[5] Leiden Univ, Med Ctr, Dept Intens Care Med, Leiden, Netherlands
[6] Amsterdam Leiden Intens Care Focused Echog ALIFE, Amsterdam, Netherlands
来源
NETHERLANDS JOURNAL OF CRITICAL CARE | 2020年 / 28卷 / 06期
关键词
ultrasound; guidance; central venous catheter; diagnostics; pneumothorax; malposition; LUNG ULTRASOUND; I-AIM; CARE; ECHOCARDIOGRAPHY; COMPLICATIONS; CONFIRMATION; DIAMETER; BUBBLE; SAFETY; POINT;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Using ultrasound as a guidance tool during central venous catheter placement has repeatedly been shown to improve procedural safety. More recent evidence has shown its potential as a diagnostic modality to detect placement-associated complications. A protocol combining these modalities is lacking. This article uses the Indication, Acquisition, Interpretation and Medical decision-making (I-AIM) model, common to other ultrasound protocols, to provide a systematic ultrasound approach to guide central venous catheter placement and assess potential related complications. It is part of a larger series published in this journal. Methods: Relevant articles were found in a thorough search in PubMed using the MeSH terms: "diagnostic imaging" or "ultrasonography" or "sonography" and "central venous catheter" or "central venous cannulation" and "complications" or "placement procedure". Studies conducted on patients younger than 18 years and studies conducted in animals were excluded. Two independent researchers evaluated the articles for relevance and quality. The results of the various studies were used to create the following structured ultrasound approach. Recommended approach: Following the I-AIM model, acquiring the most valuable images is subdivided into patient, probe, picture and protocol considerations. Ultrasound guidance during central venous catheter placement should be conducted in four steps: pre-cannulation, confirming patency, dynamic guidance during insertion, and confirmation of intravenous central venous catheter position. After these steps, ultrasound should be used in the diagnostic evaluation of malposition and iatrogenic pneumothorax. Conclusions: This model provides a comprehensive and ready to use ultrasound approach to guide central venous catheter placement and assess potential placement associated complications.
引用
收藏
页码:244 / 252
页数:9
相关论文
共 39 条
  • [1] [Anonymous], 2014, CAN J ANESTH, DOI [DOI 10.1007/S12630-014-0111-3, DOI 10.1007/s12630-014-0111-3]
  • [2] Determination of the learning curve for ultrasound-guided jugular central venous catheter placement
    Ba-Vinh Nguyen
    Prat, Gwenael
    Vincent, Jean-Louis
    Nowak, Emmanuel
    Bizien, Nicolas
    Tonnelier, Jean-Marie
    Renault, Anne
    Ould-Ahmed, Mehdi
    Boles, Jean-Michel
    L'Her, Erwan
    [J]. INTENSIVE CARE MEDICINE, 2014, 40 (01) : 66 - 73
  • [3] I-AIM A Novel Model for Teaching and Performinc Focused Sonography
    Bahner, David P.
    Hughes, Daralee
    Royall, Nelson A.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (02) : 295 - 300
  • [4] Bedel J, 2017, INTENS CARE MED, V39, P1932
  • [5] BOMMER WJ, 1984, J AM COLL CARDIOL, V3, P6, DOI 10.1016/S0735-1097(84)80423-4
  • [6] Safety of peripheral intravenous administration of vasoactive medication
    Cardenas-Garcia, Jose
    Schaub, Karen F.
    Belchikov, Yuly G.
    Narasimhan, Mangala
    Koenig, Seth J.
    Mayo, Paul H.
    [J]. JOURNAL OF HOSPITAL MEDICINE, 2015, 10 (09) : 581 - 585
  • [7] Are routine chest radiographs necessary after image-guided placement of internal jugular central venous access devices?
    Chang, TC
    Funaki, B
    Szymski, GX
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 335 - 337
  • [8] Use of Contrast-Enhanced Ultrasound for Confirmation of Central Venous Catheter Placement: Systematic Review and Meta-analysis
    Chebl, Ralph Bou
    Kiblawi, Shafeek
    El Khuri, Christopher
    El Hajj, Nadine
    Bachir, Rana
    Aoun, Roni
    Abou Dagher, Gilbert
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (12) : 2503 - 2510
  • [9] Relationship between Trendelenburg tilt and internal jugular vein diameter
    Clenaghan, S
    McLaughlin, RE
    Martyn, C
    McGovern, S
    Bowra, J
    [J]. EMERGENCY MEDICINE JOURNAL, 2005, 22 (12) : 867 - 868
  • [10] The bubble study: ultrasound confirmation of central venous catheter placement
    Duran-Gehring, Petra E.
    Guirgis, Faheem W.
    McKee, Kristin C.
    Goggans, Susan
    Huynh Tran
    Kalynych, Colleen J.
    Wears, Robert L.
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (03) : 315 - 319