Biological qualification of blood units - Considerations about the effects of sample's handling and storage on stability of nucleic acids

被引:26
作者
Gessoni, G [1 ]
Barin, P [1 ]
Valverde, S [1 ]
Giacomini, A [1 ]
Di Natale, C [1 ]
Orlandini, E [1 ]
Arreghini, N [1 ]
De Fusco, G [1 ]
Frigato, A [1 ]
Fezzi, M [1 ]
Antico, F [1 ]
Marchiori, G [1 ]
机构
[1] Osped Civile, Dept Clin Pathol, Reg Veneto, AULS Chioggia 14, I-30015 Chioggia, VE, Italy
关键词
HBV-DNA; HCV-RNA; HIV-RNA; stability; storage; biological qualification; detection-limit;
D O I
10.1016/j.transci.2003.11.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In transfusional setting introduction of nucleic amplification technique (NAT) for HBV-DNA, HCV-RNA and HIV-RNA in biological qualification of blood units suggest some problems. At first the opportunity to operate on mini-pool, at second the need to store the samples at +4 degreesC. The authors therefore have tried to estimate the impact of these conditions on the operativity of NAT testing in the transfusional setting. Methods: The following parameters has been estimated: distribution of viral-load in untreated subjects, stability of nucleic acids during storage at +4 degreesC, stability of nucleic acids after repeated cycles of freezing and defrosting, robustness of the test to the cross-contamination, definition of the detection-limit (95%). Quantitative tests has been performed by using the following kits: Cobas Amplicor HBV Monitor, Cobas Amplicor HCV Monitor, Cobas Amplicor HIV Monitor; the qualitative tests has been performed by using the following kits: Ampliscreen HBV, Ampliscreen HCV 2,0, Ampliscreen HIV 1,5 all supplied by Roche Molecular System (Brancburg, NJ). Results: Viral load in untreated subjects showed wide variation for HBV, HCV and HIV. HBV has been demonstrated much stable to the conservation +4 degreesC also until 168 h while for HCV and HIV a greater decrease of the viral-load was observed. For all and three virus the conservation to +4 degreesC until 72 It does not seem to involve meaningful fall in the viral-load. A remarkable reduction of the viral-load has been observed after five cycles of freezing and defrosting. All the tests showed a good robustness to cross-contamination. The detection-limit (95%) was 8 U/ml for HBV, 21 U/ml for HCV and 27 copy/ml for HIV. Conclusions: Samples for NAT testing, can be stored until 72 h to +4 degreesC without appreciable lowering of the viral-load. Repeated cycles of changes of state should be avoided. The tests showed a good robustness to cross-contamination. NAT tests for biological qualification of blood units had a minimal sensibility around 50 (copy/unit/ml). In our experience the detection-limit (95%) was 21 U/ml for HCV, 27copies/ml for HIV, 8 U/ml for HBV. The availability of NAT test for HBV-DNA, HCV-RNA e HIV-RNA, sensitive and reliable, together with epidemiological data, suggest the opportunity to place side by side, in the biological qualification of the blood units, to add the tests for HBV-DNA and HIV-RNA to the test for HCV-RNA mandatory by low, in Italy in the biological qualification of blood units. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 39 条
[31]   Evaluation of an automated sample preparation protocol for quantitative detection of hepatitis C virus RNA [J].
Stelzl, E ;
Kormann-Klement, A ;
Haas, J ;
Daghofer, E ;
Santner, BI ;
Marth, E ;
Kessler, HH .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (04) :1447-1450
[32]   Simultaneous extraction of hepatitis C virus (HCV),hepatitis B virus, and HIV-1 from plasma and detection of HCV RNA by a reverse transcriptase-polymerase chain reaction assay designed for screening pooled units of donated blood [J].
Sun, R ;
Schilling, W ;
Jayakar, H ;
Ku, J ;
Wang, J ;
Rosenstraus, M ;
Spadoro, J .
TRANSFUSION, 1999, 39 (10) :1111-1119
[33]  
Sun R, 2000, Dev Biol (Basel), V102, P81
[34]   Residual risk of transfusion-transmitted HCV and HIV infections by antibody-screened blood in Italy [J].
Velati, C ;
Romanò, L ;
Baruffi, L ;
Pappalettera, M ;
Carreri, V ;
Zanetti, AR .
TRANSFUSION, 2002, 42 (08) :989-993
[35]   Mathematic modeling of the risk of HBV, HCV, and HIV transmission by window-phase donations not detected by NAT [J].
Weusten, JJAM ;
van Drimmelen, HAJ ;
Lelie, PN .
TRANSFUSION, 2002, 42 (05) :537-548
[36]   Kinetics of acute hepatitis B virus infection in humans [J].
Whalley, SA ;
Murray, JM ;
Brown, D ;
Webster, GJM ;
Emery, VC ;
Dusheiko, GM ;
Perelson, AS .
JOURNAL OF EXPERIMENTAL MEDICINE, 2001, 193 (07) :847-853
[37]   Performance characteristics of the COBAS AmpliScreen HIV-1 test, version 1.5, an assay designed for screening plasma mini-pools [J].
Yang, YF ;
Lamendola, MN ;
Mendoza, M ;
Xu, D ;
Nguyen, M ;
Yeh, S ;
Wu, YQ ;
Ku, J ;
Rosenstraus, M ;
Sun, R .
TRANSFUSION, 2001, 41 (05) :643-651
[38]  
1996, EUROPEAN PHARMACOPEI
[39]  
1999, DECRETO MINISTERO IT