Task analysis; Three-dimensional displays; Two dimensional displays; Biomedical monitoring; Kinematics; Cameras; Risk management; Ergonomic risk assessment; inertial measurement unit; material handling tasks; RULA; work-related musculoskeletal disorders; ISB RECOMMENDATION; COORDINATE SYSTEM; SENSORS; MOTION; EXPOSURE; KINECT; DEFINITIONS; CALIBRATION; VALIDATION; SHOULDER;
D O I
10.1109/ACCESS.2020.3048645
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The Rapid Upper Limb Assessment (RULA) is frequently used to monitor body posture for early risk prevention of work-related musculoskeletal disorders. However, RULA measurements that are based on workers' self-report or external rater observation suffer from low repeatability. Thus, the objective of this study was to investigate the accuracy and repeatability of an inertial measurement unit (IMU) system for in-field RULA score assessment during manual material handling tasks using 3D Cardan angles and 2D projection angles against reference values obtained by a motion-capture camera system. The experimental results showed that for trunk and neck joint angles, the 2D convention had significantly (p < 0.05) smaller root-mean-square error (RMSE), while for other upper-body angles, the convention with significantly smaller RMSE depended on the angle under analysis. Also, the 3D convention showed a "moderate" agreement with the reference system, while the 2D convention showed a "substantial" agreement for two tasks and a "moderate" agreement for one task. Moreover, the intraclass correlation coefficients ranged from 0.82 to 0.94 for the 3D convention and 0.87 to 0.95 for the 2D convention for repeated trials performed by each participant. Therefore, the wearable IMU system, along with the 2D convention, could be considered as an accurate and repeatable ergonomic risk assessment tool.
引用
收藏
页码:7293 / 7305
页数:13
相关论文
共 50 条
  • [1] In-field instrumented ergonomic risk assessment: Inertial measurement units versus Kinect V2
    Humadi, Ahmed
    Nazarahari, Milad
    Ahmad, Rafiq
    Rouhani, Hossein
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2021, 84
  • [2] K-score: A novel scoring system to quantify fatigue-related ergonomic risk based on joint angle measurements via wearable inertial measurement units
    Martinez, Karla Beltran
    Nazarahari, Milad
    Rouhani, Hossein
    APPLIED ERGONOMICS, 2022, 102
  • [3] Improved Ergonomic Risk Factor Assessment Using OpenSim and Inertial Measurement Units
    Mortensen, Jonathan
    Trkov, Mitja
    Merryweather, Andrew
    2018 IEEE/ACM INTERNATIONAL CONFERECE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2018, : 27 - 28
  • [4] Ergonomic assessment of office worker postures using 3D automated joint angle assessment
    Rodrigues, Patrick B.
    Xiao, Yijing
    Fukumura, Yoko E.
    Awada, Mohamad
    Aryal, Ashrant
    Becerik-Gerber, Burcin
    Lucas, Gale
    Roll, Shawn C.
    ADVANCED ENGINEERING INFORMATICS, 2022, 52
  • [5] Fall-risk assessment of aged workers using wearable inertial measurement units based on machine learning
    Kou, Junhui
    Xu, Xin
    Ni, Xiaoyang
    Ma, Shengkai
    Guo, Liangjie
    SAFETY SCIENCE, 2024, 176
  • [6] Quantification of inertial sensor-based 3D joint angle measurement accuracy using an instrumented gimbal
    Brennan, A.
    Zhang, J.
    Deluzio, K.
    Li, Q.
    GAIT & POSTURE, 2011, 34 (03) : 320 - 323
  • [7] Joint Parameter Estimation Using Magneto and Inertial Measurement Units
    Liu, Yu-Tao
    Zhang, Yong-An
    Zeng, Ming
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 2225 - 2230
  • [8] Upper limb joint kinematics using wearable magnetic and inertial measurement units: an anatomical calibration procedure based on bony landmark identification
    Picerno, Pietro
    Caliandro, Pietro
    Iacovelli, Chiara
    Simbolotti, Chiara
    Crabolu, Michele
    Pani, Danilo
    Vannozzi, Giuseppe
    Reale, Giuseppe
    Rossini, Paolo Maria
    Padua, Luca
    Cereatti, Andrea
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [9] Recognizing Manual Activities Using Wearable Inertial Measurement Units: Clinical Application for Outcome Measurement
    El Khoury, Ghady
    Penta, Massimo
    Barbier, Olivier
    Libouton, Xavier
    Thonnard, Jean-Louis
    Lefevre, Philippe
    SENSORS, 2021, 21 (09)
  • [10] Measurement of Hand Joint Angle Using Inertial-Based Motion Capture System
    Lu, Chenghong
    Dai, Zeyang
    Jing, Lei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72