Exact H2 optimal solutions to inerter-based isolation systems for building structures

被引:124
作者
Sun, Hongxin [1 ,2 ]
Zuo, Lei [2 ]
Wang, Xiuyong [1 ]
Peng, Jian [1 ]
Wang, Wenxi [3 ]
机构
[1] Hunan Univ Sci & Technol, Sch Civil Engn, Hunan Prov Key Lab Struct Engn Wind Resistant & V, Xiangtan 411201, Peoples R China
[2] Virginia Tech, Dept Mech Engn, Blacksburg, VA 24060 USA
[3] Hunan Univ, Coll Civil Engn, Key Lab Bridge & Wind Engn Hunan Prov, Changsha, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
base isolation; H-2; optimization; inerter dampers; structural control; tuned inerter damper; TUNED MASS-DAMPER; OF-THE-ART; MECHANICAL NETWORKS; SEISMIC PROTECTION; OPTIMAL-DESIGN; PERFORMANCE; OPTIMIZATION; MITIGATION; TMDI;
D O I
10.1002/stc.2357
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents two inerter-based isolation systems, namely, an inerter-damper (ID)-based isolation with an inerter in parallel with a viscous damper and a tuned ID (TID)-based isolation composed of an inerter in series with a spring-damper pair. A base-isolated building with two degrees of freedom (DOF) is considered, where the superstructure above the base is simplified as a single DOF. The H-2 norm performances of the ID- and TID-based isolation systems are introduced in comparison with the traditional isolation system, with the aim to minimize structure damage under random excitation from ground acceleration. The closed-form solutions are obtained, including the damping ratio of the traditional isolation, the damping ratio and the inertance-to-mass ratio of the ID-based isolation, and the damping ratio and inerter frequency tuning ratio of the TID-based isolation. It is shown that the TID-based isolation is superior to both the traditional and ID-based isolation systems for vibration control. Specifically, the optimal H-2 norm of the transmission from the ground acceleration to the building relative displacement in the TID-based isolation can be reduced by 7.5%. The influence of the primary damping of the building structures is also studied numerically, in both the frequency and time domains, and compared with the exact optimal solution of the undamped structure. The simulations using recorded earthquake spectra show that the ID- and TID-based isolations can further reduce the story drift, the base displacement as much as 48.5% and 66.3% (root mean square) and 37.8% and 71.9% (peak) for the El Centro record compared with the traditional isolation system.
引用
收藏
页数:21
相关论文
共 57 条
[1]  
[Anonymous], 2017, SHOCK VIB, DOI DOI 10.1155/2017/2314858
[2]   Enhanced performance through a dual isolation seismic protection system [J].
Becker, Tracy C. ;
Ezazi, Ashkan .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2016, 25 (01) :72-89
[3]   Novel type of tuned mass damper with inerter which enables changes of inertance [J].
Brzeski, P. ;
Kapitaniak, T. ;
Perlikowski, P. .
JOURNAL OF SOUND AND VIBRATION, 2015, 349 :56-66
[4]   The application of inerter in tuned mass absorber [J].
Brzeski, P. ;
Pavlovskaia, E. ;
Kapitaniak, T. ;
Perlikowski, P. .
INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2015, 70 :20-29
[5]   The Missing Mechanical Circuit Element [J].
Chen, Michael Z. Q. ;
Papageorgiou, Christos ;
Scheibe, Frank ;
Wang, Fu-Cheng ;
Smith, Malcolm C. .
IEEE CIRCUITS AND SYSTEMS MAGAZINE, 2009, 9 (01) :10-26
[6]   OPTIMUM CHARACTERISTICS OF ISOLATED STRUCTURES [J].
CONSTANTINOU, MC ;
TADJBAKHSH, IG .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1985, 111 (12) :2733-2750
[7]   Soil-dependent optimum design of a new passive vibration control system combining seismic base isolation with tuned inerter damper [J].
De Domenico, D. ;
Impollonia, N. ;
Ricciardi, G. .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 105 :37-53
[8]   Optimal design and seismic performance of tuned mass damper inerter (TMDI) for structures with nonlinear base isolation systems [J].
De Domenico, Dario ;
Ricciardi, Giuseppe .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (12) :2539-2560
[9]   An enhanced base isolation system equipped with optimal tuned mass damper inerter (TMDI) [J].
De Domenico, Dario ;
Ricciardi, Giuseppe .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (05) :1169-1192
[10]   Optimal tuned mass-damper-inerter (TMDI) design for seismically excited MDOF structures with model uncertainties based on reliability criteria [J].
Giaralis, A. ;
Taflanidis, A. A. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (02)