Rapid determination of granisetron in human plasma by liquid chromatography coupled to tandem mass spectrometry and its application to bioequivalence study

被引:27
作者
Jiang, Yunyun
Lin, Mei
Fan, Guorong
Chen, Yi
Li, Zhen
Zhao, Weiquan
Wu, Yutian
Hu, Jinhong
机构
[1] Second Mil Med Univ, Dept Pharmaceut Anal, Sch Pharm, Shanghai 200433, Peoples R China
[2] Second Mil Med Univ, Shanghai Key Lab Pharmaceut Metabolite Res, Sch Pharm, Shanghai 200433, Peoples R China
[3] Shanghai Inst Drug Control, Shanghai 200233, Peoples R China
[4] Changhai Hosp, Dept Clin Pharmacol, Shanghai 200433, Peoples R China
关键词
granisetron; LC-MS/MS; plasma; pharmacokinetics; bioequivalence;
D O I
10.1016/j.jpba.2006.05.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and rapid method for analysis of granisetron in human plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and validated to satisfy FDA guidelines for bioanalytical methods. The analyte and internal standard (IS) were isolated from 100 mu l plasma samples by liquid-liquid extraction (LLE). A Varian 12001 tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 313.4/138 for granisetron and m/z 270/201 for the IS used for quantitation. The assay exhibited a linear dynamic range of 0.02-20 ng/ml for granisetron in human plasma. The lower limit of quantification (LLOQ) was 0.02 ng/ml with a relative standard deviation of less than 15%. The mean extraction recovery from spiked plasma samples was 97.9%. The intra-day accuracy of the assay was within 10% of nominal and intra-day precision was better than 15% C.V. A run time of 2.0 min for each sample made it possible for high-throughput bioanalysis. The method was employed in a bioequivalence study of two formulations of granisetron hydrochloride 1 mg rapidly disintegrating tablets/1 mg capsules. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:464 / 473
页数:10
相关论文
共 50 条
  • [41] A simple, selective and rapid validated method for estimation of anastrazole in human plasma by liquid chromatography tandem mass spectrometry and its application to bioequivalence study
    Jangid, Arvind G.
    Pudage, Ashutosh M.
    Joshi, Santosh S.
    Pabrekar, Pramod N.
    Tale, Rajesh H.
    Vaidya, Vikas V.
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (07) : 727 - 731
  • [42] Determination of torasemide in human plasma and its bioequivalence study by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry
    Zhang, Lin
    Wang, Rulin
    Tian, Yuan
    Zhang, Zunjian
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2016, 6 (02) : 95 - 102
  • [43] Determination of azasetron hydrochloride in rabbit plasma by liquid chromatography tandem mass spectrometry and its application
    Lin, Guanyang
    Ma, Jianshe
    Zhu, Jiayin
    Yang, Xuezhi
    Hu, Lufeng
    Wang, Xianqin
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (10) : 1107 - 1111
  • [44] Determination of torasemide in human plasma and its bioequivalence study by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry
    Lin Zhang
    Rulin Wang
    Yuan Tian
    Zunjian Zhang
    Journal of Pharmaceutical Analysis, 2016, 6 (02) : 95 - 102
  • [45] A rapid, simple and sensitive method for the determination and bioequivalence study of transdermal fentanyl in human plasma using liquid chromatography-electrospray ionization tandem mass spectrometry
    Cheng, Shu-Qiao
    Ouyang, Dong-Sheng
    Tang, Yong-Jun
    Wu, Kai
    Xiao, Jian
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2016, 54 (02) : 144 - 156
  • [46] HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY FOR THE DETERMINATION OF TROSPIUM CHLORIDE IN HUMAN PLASMA AND ITS APPLICATION IN A BIOEQUIVALENCE STUDY
    Tang, Jing
    Tan, Zhi-Rong
    Zhou, Yan-Bin
    Ding, Jin-Song
    ANALYTICAL LETTERS, 2011, 44 (04) : 607 - 616
  • [47] Simultaneous determination of irbesartan and hydrochlorothiazide in human plasma by ultra high performance liquid chromatography tandem mass spectrometry and its application to a bioequivalence study
    Qiu, Xiangjun
    Wang, Zhe
    Wang, Bing
    Zhan, Hui
    Pan, Xiaofeng
    Xu, Ren-ai
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 957 : 110 - 115
  • [48] Determination of perhexiline and its metabolite hydroxyperhexiline in human plasma by liquid chromatography/tandem mass spectrometry
    Zhang, Mei
    Moore, Grant A.
    Barclay, Murray L.
    Begg, Evan J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27): : 3025 - 3030
  • [49] Liquid chromatography tandem mass spectrometry assay for the simultaneous determination of venlafaxine and O-desmethylvenlafaxine in human plasma and its application to a bioequivalence study
    Patel, Bhavin N.
    Sharma, Naveen
    Sanyal, Mallika
    Shrivastav, Pranav S.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (03) : 603 - 611
  • [50] Validated method for determination of bromopride in human plasma by liquid chromatography-electrospray tandem mass spectrometry: application to the bioequivalence study
    Nazare, P
    Massaroti, P
    Duarte, LF
    Campos, DR
    Marchioretto, MAM
    Bernasconi, G
    Calafatti, S
    Barros, FAP
    Meurer, EC
    Pedrazzoli, J
    Moraes, LAB
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (09): : 1197 - 1202