Rapid determination of granisetron in human plasma by liquid chromatography coupled to tandem mass spectrometry and its application to bioequivalence study

被引:27
作者
Jiang, Yunyun
Lin, Mei
Fan, Guorong
Chen, Yi
Li, Zhen
Zhao, Weiquan
Wu, Yutian
Hu, Jinhong
机构
[1] Second Mil Med Univ, Dept Pharmaceut Anal, Sch Pharm, Shanghai 200433, Peoples R China
[2] Second Mil Med Univ, Shanghai Key Lab Pharmaceut Metabolite Res, Sch Pharm, Shanghai 200433, Peoples R China
[3] Shanghai Inst Drug Control, Shanghai 200233, Peoples R China
[4] Changhai Hosp, Dept Clin Pharmacol, Shanghai 200433, Peoples R China
关键词
granisetron; LC-MS/MS; plasma; pharmacokinetics; bioequivalence;
D O I
10.1016/j.jpba.2006.05.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and rapid method for analysis of granisetron in human plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and validated to satisfy FDA guidelines for bioanalytical methods. The analyte and internal standard (IS) were isolated from 100 mu l plasma samples by liquid-liquid extraction (LLE). A Varian 12001 tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 313.4/138 for granisetron and m/z 270/201 for the IS used for quantitation. The assay exhibited a linear dynamic range of 0.02-20 ng/ml for granisetron in human plasma. The lower limit of quantification (LLOQ) was 0.02 ng/ml with a relative standard deviation of less than 15%. The mean extraction recovery from spiked plasma samples was 97.9%. The intra-day accuracy of the assay was within 10% of nominal and intra-day precision was better than 15% C.V. A run time of 2.0 min for each sample made it possible for high-throughput bioanalysis. The method was employed in a bioequivalence study of two formulations of granisetron hydrochloride 1 mg rapidly disintegrating tablets/1 mg capsules. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:464 / 473
页数:10
相关论文
共 17 条
[1]   Granisetron: An update on its clinical use in the management of nausea and vomiting [J].
Aapro, M .
ONCOLOGIST, 2004, 9 (06) :673-686
[2]  
ALLEN A, 1994, EUR J CLIN PHARMACOL, V46, P159
[3]  
[Anonymous], BIOAV BIOEQ STUD OR
[5]   Direct plasma liquid chromatographic-tandem mass spectrometric analysis of granisetron and its 7-hydroxy metabolite utilizing internal surface reversed-phase guard columns and automated column switching devices [J].
Boppana, VK ;
MillerStein, C ;
Schaefer, WH .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 678 (02) :227-236
[6]   AN HPLC METHOD FOR THE DETERMINATION OF GRANISETRON IN GUINEA-PIG PLASMA [J].
CAPACIO, BR ;
BYERS, CE ;
JACKSON, TK ;
MATTHEWS, RL .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (03) :151-155
[7]  
CARMICHAEL J, 1989, CANCER CHEMOTH PHARM, V24, P45
[8]   EVALUATION OF THE BIOEQUIVALENCE OF TABLET AND CAPSULE FORMULATIONS OF GRANISETRON IN PATIENTS UNDERGOING CYTOTOXIC CHEMOTHERAPY FOR MALIGNANT DISEASE [J].
CUPISSOL, D ;
BRESSOLLE, F ;
ADENIS, L ;
CARMICHAEL, J ;
BESSELL, E ;
ALLEN, A ;
WARGENAU, M ;
ROMAIN, D .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1993, 82 (12) :1281-1284
[9]  
*FDA GUID IDN, 2001, STAT APPR EST BIOEQ
[10]   Simultaneous measurement of blood and brain microdialysates of granisetron in rat by high-performance liquid chromatography with fluorescence detection [J].
Huang, C ;
Chen, KC ;
Chen, CF ;
Tsai, TH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 716 (1-2) :251-255