Finite Element Analysis of Stress in Maxillary Dentition during En-masse Retraction with Implant Anchorage

被引:6
作者
Suzuki, Masayoshi [1 ]
Sueishi, Kenji [2 ]
Katada, Hidenori [2 ]
Togo, Satoshi [3 ]
机构
[1] Tokyo Dent Coll, Dept Orthodont, Mihama Ku, 1-2-2 Masago, Chiba 2618502, Japan
[2] Tokyo Dent Coll, Dept Orthodont, Chiyoda Ku, 2-9-18 Kanda Misakicho, Tokyo 1010061, Japan
[3] Togo Orthodont Clin, 2-18-1 Motanakayama, Funabashi, Chiba 2730035, Japan
关键词
Finite element analysis; En-masse retraction; Implant anchor; Center of resistance; Wire deformation; LASER REFLECTION TECHNIQUE; ANTERIOR TEETH; SLIDING MECHANICS; TOOTH MOVEMENT; RESISTANCE; DISPLACEMENT; SIMULATION; LOCATION; CENTERS; SEGMENT;
D O I
10.2209/tdcpublication.2017-0055
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The goal of this study was to investigate how the height of the archwire hook and implant anchor affect tooth movement, stress in the teeth and alveolar bone, and the center of resistance during retraction of the entire maxillary dentition using a multi-bracket system. Computed tomography was used to scan a dried adult human skull with normal occlusion. Three-dimensional models of the maxillary bone, teeth, brackets, archwire, hook, and implant anchor were created and used for finite element analysis. The heights of the hook and the implant anchor were set at 0, 5, or 10 mm from the archwire. Orthodontic force of 4.9 N was systematically applied between the hook and the implant anchor and differential stress distributions and tooth movements observed for each traction condition. With horizontal traction, the archwire showed deformation in the superior direction anterior to the hook and in the inferior direction posterior to the hook. Differences in traction height and direction resulted in different degrees of deformation, with biphasic movement clearly evident both in front of and behind the hook. With horizontal traction of the hook at a height of 0 mm, all the teeth moved distally, but not with any other type of traction. At a height of 5 mm or 10 mm, deformation showed an increase. The central incisor showed extrusion under all traction conditions, with the amount showing a reduction as the height of horizontal or posterosuperior traction increased. The center of resistance was located at the root of the 6 anterior teeth and entire maxillary dentition. The present results suggest that it is necessary to consider deformation of the wire and the center of resistance during en-masse retraction with implant anchorage.
引用
收藏
页码:39 / 52
页数:14
相关论文
共 50 条
  • [1] Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position
    Song, Jae-Won
    Lim, Joong-Ki
    Lee, Kee-Joon
    Sung, Sang-Jin
    Chun, Youn-Sic
    Mo, Sung-Seo
    KOREAN JOURNAL OF ORTHODONTICS, 2016, 46 (04) : 242 - 252
  • [2] Finite Element Analysis of Maxillary Teeth Movement with Time during En Masse Retraction Using Orthodontic Mini-Screw
    Hwang, Jeong-Bo
    Mo, Sung-Seo
    APPLIED SCIENCES-BASEL, 2023, 13 (06):
  • [3] Three-Dimensional Finite Element Analysis on En-Masse Retraction of the Maxillary Anterior Teeth With Quantitative Combined Loading Control
    Qie, Hui
    Kong, Lingliang
    Zhang, Fan
    Li, Chenxi
    Lu, Lin
    Dou, Chenlei
    Shan, Lihua
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) : 214 - 220
  • [4] Effects of canine movement on maxillary anterior en-masse retraction with clear aligners: a finite element study
    Tang, Xin Yue
    Jiang, Ting
    Su, Han
    Chin, Daphne Yuchen
    Chen, Jia Yi
    Qin, Yu Qi
    Tang, Guo Hua
    BMC ORAL HEALTH, 2025, 25 (01):
  • [5] Palatal en-masse retraction of segmented maxillary anterior teeth: A finite element study
    Park, Jae Hyun
    Kook, Yoon-Ah
    Kojima, Yukio
    Yun, Sunock
    Chae, Jong-Moon
    KOREAN JOURNAL OF ORTHODONTICS, 2019, 49 (03) : 188 - +
  • [6] Effect of power arm length combined with additional anterior torque on the axial orientation of the maxillary incisors during en-masse retraction: A finite element analysis
    Zalaquett, Rime
    Karam, Richard
    Kaddah, Fouad
    Khoury, Elie
    El Khoury, Tony
    Ghoubril, Joseph
    Kassis, Adib
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2024, 165 (02) : 220 - 231
  • [7] Evaluation of stress pattern in periodontium and change in inclination during en masse retraction: Finite element analysis
    Kalia, Himanshu
    Gupta, Seema
    Ahuja, Sachin
    Bhambri, Eenal
    Goyal, Ankit
    Sharma, Rohini
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2019, 8 (04) : 153 - 158
  • [8] Stress Analysis of Periodontal Tissue in en Masse Retraction With Integration of Maxillary Anterior Teeth: A Three-Dimensional Finite Element Method Study
    Saito, Ran
    Ozaki, Hiroya
    Fushima, Kenji
    Arisaka, Hirofumi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [9] Dual-section versus conventional archwire for en-masse retraction of anterior teeth with direct skeletal anchorage: a finite element analysis
    Hamanaka, Ryo
    Cantarella, Daniele
    Lombardo, Luca
    Karanxha, Lorena
    Del Fabbro, Massimo
    Siciliani, Giuseppe
    Yoshida, Noriaki
    BMC ORAL HEALTH, 2021, 21 (01)
  • [10] Evaluation of Stress Distribution of Maxillary Anterior Segment during en Masse Retraction Using Posterior Mini Screw: A Finite Element Study
    Ali, Meer Juned
    Bhardwaj, Amit
    Khan, Mohammad Shoyab
    Alwadei, Farhan
    Gufran, Khalid
    Alqahtani, Abdullah Saad
    Alqhtani, Nasser Raqe
    Alasqah, Mohammed
    Alsakr, Abdulaziz Mohammad
    Alghabban, Rawda Omar
    APPLIED SCIENCES-BASEL, 2022, 12 (20):