A system for continuous production and infusion of [15O]H2O for PET activation studies

被引:4
作者
Sajjad, M [1 ]
Liow, JS
Moreno-Cantu, J
机构
[1] Vet Adm Med Ctr, PET Imaging Serv, Minneapolis, MN 55417 USA
[2] Univ Minnesota, Dept Radiol, Minneapolis, MN 55455 USA
关键词
PET; oxygen-15;
D O I
10.1016/S0969-8043(99)00123-2
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A system for continuous production and infusion of [O-15]H2O has been designed for Positron Emission Tomography brain activation studies. The infusion system consists of two Horizon Nxt infusion pumps, a four-port-two-position valve and a sterile 50 mi vial. The line and the back check valve between the furnace and the reservoir were heated in order to reduce vapor condensation in the line. The variation of the production of [O-15]H2O was <1%, The activity delivered as measured by scanner counts varied <2% during the steady state period. The system has been demonstrated to be capable of delivering activity over a wide range of conditions. Published by Elsevier Science Ltd.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 12 条
  • [1] BERRIDGE MS, 1990, APPL RADIAT ISOTOPES, V41, P1173
  • [2] FERRIS RM, 1994, PLAST ENG, V50, P2
  • [3] CEREBRAL BLOOD-FLOW WITH THE CONTINUOUS INFUSION OF OXYGEN-15-LABELED WATER
    JONES, SC
    GREENBERG, JH
    DANN, R
    ROBINSON, GD
    KUSHNER, M
    ALAVI, A
    REIVICH, M
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1985, 5 (04) : 566 - 575
  • [4] MEASUREMENT OF CEREBRAL BLOOD-FLOW USING BOLUS INHALATION OF (CO2)-O-15 AND POSITRON EMISSION TOMOGRAPHY - DESCRIPTION OF THE METHOD AND ITS COMPARISON WITH THE (CO2)-O-15 CONTINUOUS INHALATION METHOD
    KANNO, I
    LAMMERTSMA, AA
    HEATHER, JD
    GIBBS, JM
    RHODES, CG
    CLARK, JC
    JONES, T
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (02) : 224 - 234
  • [5] KEARFOTT KJ, 1983, J COMPUT ASSIST TOMO, V7, P51, DOI 10.1097/00004728-198302000-00009
  • [6] Matzke K.-H., 1993, Journal of Labelled Compounds and Radiopharmaceuticals, V32, P459
  • [7] MORENOCANTU JJ, 1999, J CEREB BLOOD FLOW M, V19, pS814
  • [8] AN AUTOMATED [O-15]H2O PRODUCTION AND INJECTION SYSTEM FOR PET IMAGING
    PALMER, BM
    SAJJAD, M
    ROTTENBERG, DA
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 1995, 22 (02): : 241 - 249
  • [9] PASCJAK PS, 1992, 12 INT C APPL ACC RE, P59
  • [10] PHYSICAL PERFORMANCE OF A POSITRON TOMOGRAPH FOR BRAIN IMAGING WITH RETRACTABLE SEPTA
    SPINKS, TJ
    JONES, T
    BAILEY, DL
    TOWNSEND, DW
    GROOTOONK, S
    BLOOMFIELD, PM
    GILARDI, MC
    CASEY, ME
    SIPE, B
    REED, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (08) : 1637 - 1655