Analysis of short circuit current of wind turbine - Doubly fed induction generator

被引:0
作者
Li, D. D. [1 ]
机构
[1] Shanghai Univ Elect Power, Sch Elect Power & Automat Engn, Shanghai 200090, Peoples R China
来源
ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS | 2006年
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With continual installation of wind power generators, proportion of wind energy increases dramatically in electric power system, and influence of wind power must be considered in power system analysis or design. Calculation of short circuit current is an important task for wind farm and power system. Doubly fed induction generators (DFIG) are widely equipped for wind turbines, and this type of wind power generator is studied in detail in this paper. Transient of DFIG is analyzed under short circuit condition, and the theorem of constant flux linkage is applied to determine short circuit currents in the synchronously rotating reference frame dq0. In succession, formulas for calculation of the short circuit currents are deduced. Comparison of the calculation results with simulation results shows validity of the proposed formulas.
引用
收藏
页码:1082 / 1086
页数:5
相关论文
共 50 条
  • [31] Flicker mitigation in a doubly fed induction generator wind turbine system
    Machmoum, Mohamed
    Hatoum, Ahmad
    Bouaouiche, Toufik
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2010, 81 (02) : 433 - 445
  • [32] Internal electrical protection of wind turbine with doubly fed induction generator
    Mansouri, M. Mahdi
    Nayeripour, Majid
    Negnevitsky, Michael
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 55 : 840 - 855
  • [33] A Supersynchronous Doubly Fed Induction Generator Option for Wind Turbine Applications
    Lipo, T. A.
    2009 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS, 2009, : 130 - 134
  • [34] Modeling and Slip Control of A Doubly Fed Induction Wind Turbine Generator
    Fan, Lingling
    Yuvarajan, Subbaraya
    2008 40TH NORTH AMERICAN POWER SYMPOSIUM (NAPS 2008), 2008, : 522 - 527
  • [35] Reactive Power Capability of the Wind Turbine with Doubly Fed Induction Generator
    Tian, J.
    Su, C.
    Chen, Z.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 5312 - 5317
  • [36] Frequency Response Model of Doubly Fed Induction Generator Wind Turbine
    Li, Luyang
    Chen, Lei
    Min, Yong
    Xiong, Xuejun
    Feng, Yuyao
    Yi, Pei
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 940 - 945
  • [37] Modeling and Control of a Wind Turbine Based On a Doubly Fed Induction Generator
    Noussi, K.
    Abouloifa, A.
    Katir, H.
    Lachkar, I.
    PROCEEDINGS OF 2019 IEEE 4TH WORLD CONFERENCE ON COMPLEX SYSTEMS (WCCS' 19), 2019, : 359 - 363
  • [38] Decentralized nonlinear control of wind turbine with doubly fed induction generator
    Wu, Feng
    Zhang, Xiao-Ping
    Ju, Ping
    Sterling, Michael J. H.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (02) : 613 - 621
  • [39] MODEL PREDICTIVE CONTROL OF WIND TURBINE WITH DOUBLY FED INDUCTION GENERATOR
    Zhang, Jing
    Yu, Peijia
    Li, Bowen
    Shi, Bangsong
    FRESENIUS ENVIRONMENTAL BULLETIN, 2017, 26 (12A): : 539 - 544
  • [40] Modeling and control of a wind turbine driven doubly fed induction generator
    Tapia, A
    Tapia, G
    Ostolaza, JX
    Sáenz, JR
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (02) : 194 - 204