Ultrasonic Versus Drills Implant Site Preparation: A Histologic Analysis in Bovine Ribs

被引:19
作者
Scarano, Antonio [1 ]
Iezzi, Giovanna [1 ]
Perrotti, Vittoria [1 ]
Tete, Stefano [1 ]
Staiti, Giorgio [2 ]
Mortellaro, Carmen [3 ]
Cappucci, Claudia [1 ]
机构
[1] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, Chieti, Italy
[2] Univ Piemonte Orientale, Sch Dent, Novara, Italy
[3] A Avogadro Univ Eastern Piedmont, Dept Hlth Sci, Novara, Italy
关键词
Piezosurgery; ultrasonic surgery device; microcracks; transmitted light microscope; INTERDENTAL OSTEOTOMIES; BONE; PIEZOSURGERY; SURGERY; OSSEOINTEGRATION;
D O I
10.1097/SCS.0000000000000713
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Ultrasonic surgery is a recently developed system for cutting bone with microvibrations. The aim of the current study was a histologic comparison between conventional drills versus ultrasonic surgery devices in implant bed preparation. Methods: Ten bovine ribs were used, and a total of 100 perforations were randomly performed: half (n = 50) (group A) of the perforations were done through conventional drills using a single cylindrical bur (Bone System, Milan, Italy), 13 mm in height and 2 mm in width at a speed of 400 rpm, and the other half (n = 50) (group B) using an ultrasonic device (Surgysonic; Esacrom, Imola Italy), mounted with a diamond-coated cylindrical tip. After implant sites' preparation, the ribs were immediately stored in 10% buffered formalin and processed to obtain thin ground sections. Results: At higher magnification, microcracks at the interface were detected. In group A, they were numerous and showed a thickness and depth ranging from 20 to 120 mu m and from 500 to 1000 mu m, respectively. In group B, very few or no microcracks were present. Statistically significant differences were found in the microcracks density in the cortical bone but not in the cancellous bone. Conclusions: The findings from this study suggest that ultrasonic implant site preparation showed a higher performance in terms of accuracy and uniformity of the osteotomy cut, compared with conventional rotary instruments. Further studies should be conducted to understand whether a smooth, congruent implant bed able to retain fine bone structures may affect the early phases of bone healing and therefore improve osseointegration.
引用
收藏
页码:814 / 817
页数:4
相关论文
共 25 条
[1]   Biological and biomechanical evaluation of bone remodelling and implant stability after using an osteotome technique [J].
Büchter, A ;
Kleinheinz, J ;
Wiesmann, HP ;
Kersken, J ;
Nienkemper, M ;
von Weyhrother, H ;
Joos, U ;
Meyer, U .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (01) :1-8
[2]   Autogenous bone chips:: influence of a new piezoelectric device (Piezosurgery®) on chip morphology, cell viability and differentiation [J].
Chiriac, G ;
Herten, M ;
Schwarz, F ;
Rothamel, D ;
Becker, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (09) :994-999
[3]   HEALING OF SURGICAL DEFECTS IN ALVEOLAR BONE PRODUCED WITH ULTRASONIC INSTRUMENTATION, CHISEL, AND ROTARY BUR [J].
HORTON, JE ;
TARPLEY, TM ;
WOOD, LD .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1975, 39 (04) :536-546
[4]  
Iyer S, 1997, INT J PROSTHODONT, V10, P536
[5]   Piezosurgery -: a new safe technique in cranial osteoplasty? [J].
Kotrikova, B. ;
Wirtz, R. ;
Krempien, R. ;
Blank, J. ;
Eggers, G. ;
Samiotis, A. ;
Muehling, J. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (05) :461-465
[6]   Critical evaluation of piezoelectric osteotomy in orthognathic surgery:: Operative technique, blood loss, time requirement, nerve and vessel integrity [J].
Landes, Constantin A. ;
Stuebinger, Stefan ;
Rieger, Joerg ;
Williger, Babett ;
Ha, Thi Khanh Linh ;
Sader, Robert .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (04) :657-674
[7]   Comparison of pain severity following video-assisted thoracoscopic sympathectomy: electric versus harmonic scalpels [J].
Milanez de Campos, Jose Ribas ;
Wolosker, Nelson ;
Yazbek, Guilherme ;
Munia, Marco Antonio ;
Kauffman, Paulo ;
Puech-Leao, Pedro ;
Jatene, Fabio Biscegli .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 10 (06) :919-922
[8]  
Morgan T A, 2001, Int J Adult Orthodon Orthognath Surg, V16, P255
[9]   Cytokines and growth factors involved in the osseointegration of oral titanium implants positioned using piezoelectric bone surgery versus a drill technique: A pilot study in minipigs [J].
Preti, Giulio ;
Martinasso, Germana ;
Peirone, Bruno ;
Navone, Roberto ;
Manzella, Carlo ;
Muzio, Giuliana ;
Russo, Crescenzo ;
Canuto, Rosa A. ;
Schierano, Gianmario .
JOURNAL OF PERIODONTOLOGY, 2007, 78 (04) :716-722
[10]  
Ramli R, 2009, INT J ORAL MAX IMPL, V24, P591