Computational design and experimental performance testing of an axial-flow pediatric ventricular assist device

被引:28
作者
Throckmorton, Amy L. [1 ]
Lim, D. Scott
McCulloch, Michael A.
Jiang, Wei
Song, Xinwei
Allaire, Paul E.
Wood, Houston G.
Olsen, Don B.
机构
[1] Univ Virginia, Virginia Artificial Heart Inst, Dept Biomed Engn, Charlottesville, VA 22903 USA
[2] Univ Virginia, Virginia Artificial Heart Inst, Dept Mech & Aerosp Engn, Charlottesville, VA USA
[3] Univ Virginia, Sch Med, Dept Pediat, Div Pediat Cardiol, Charlottesville, VA 22908 USA
[4] Utah Artificial Heart Inst, Salt Lake City, UT USA
关键词
D O I
10.1097/01.mat.0000177541.53513.a8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Virginia Artificial Heart Institute continues to design and develop an axial-flow pediatric ventricular assist device (PVAD) for infants and children in the United States. Our research team has created a database to track potential PVAD candidates at the University of Virginia Children's Hospital. The findings of this database aided with need assessment and design optimization of the PVAD. A numerical analysis of the optimized PVAD1 design (PVAD2 model) was also completed using computational fluid dynamics (CFD) to predict pressure-flow performance, fluid force estimations, and blood damage levels in the flow domain. Based on the PVAD2 model and after alterations to accommodate manufacturing, a plastic prototype for experimental flow testing was constructed via rapid prototyping techniques or stereolithography. CFD predictions demonstrated a pressure rise range of 36-118 mm Hg and axial fluid forces of 0.8-1.7 N for flows of 0.5-3 l/min over 7,000-9,000 rpm. Blood damage indices per CFD ranged from 0.24% to 0.35% for 200 massless and inert particles analyzed. Approximately 187 (93.5%) of the particles took less than 0.14 seconds to travel completely through the PVAD. The mean residence time was 0.105 seconds with a maximum time of 0.224 seconds. Additionally, in a water/glycerin blood analog solution, the plastic prototype produced pressure rises of 20-160 mm Hg for rotational speeds of 5,960 +/- 18 rpm to 9,975 +/- 31 rpm over flows from 0.5 to 4.5 l/min. The numerical results for the PVAD2 and the prototype hydraulic testing indicate an acceptable design for the pump, represent a significant step in the development phase of this device, and encourage manufacturing of a magnetically levitated prototype for animal experiments.
引用
收藏
页码:629 / 635
页数:7
相关论文
共 21 条
[1]  
Allaire P, 1998, ARTIF ORGANS, V22, P475
[2]   Prototype continuous flow ventricular assist device supported on magnetic bearings [J].
Allaire, PE ;
Kim, HC ;
Maslen, EH ;
Olsen, DB ;
Bearnson, GB .
ARTIFICIAL ORGANS, 1996, 20 (06) :582-590
[3]   Blood flow in a continuous flow ventricular assist device [J].
Allaire, PE ;
Wood, HG ;
Awad, RS ;
Olsen, DB .
ARTIFICIAL ORGANS, 1999, 23 (08) :769-773
[4]   Computational fluid dynamics and experimental validation of a microaxial blood pump [J].
Apel, J ;
Neudel, F ;
Reul, H .
ASAIO JOURNAL, 2001, 47 (05) :552-558
[5]   Characterization of a magnetic bearing system and fluid properties for a continuous flow ventricular assist device [J].
Baloh, MJ ;
Allaire, PE ;
Hilton, EF ;
Wei, NH ;
Olsen, SB ;
Bearnson, SB ;
Khanwilkar, PS .
ARTIFICIAL ORGANS, 1999, 23 (08) :792-796
[6]  
Blackshear PL, 1987, HDB BIOENGINEERING, V1
[7]   3-DIMENSIONAL NUMERICAL PREDICTION OF STRESS LOADING OF BLOOD PARTICLES IN A CENTRIFUGAL PUMP [J].
BLUDSZUWEIT, C .
ARTIFICIAL ORGANS, 1995, 19 (07) :590-596
[8]   MODEL FOR A GENERAL MECHANICAL BLOOD DAMAGE PREDICTION [J].
BLUDSZUWEIT, C .
ARTIFICIAL ORGANS, 1995, 19 (07) :583-589
[9]  
EMMANOUILIDES G, 1995, MOSS ADAMS HEART DIS, V2
[10]  
Grady Denise, 2001, NY TIMES